Daikin FTX24NMVJU / RX24NMVJU 2-Ton Wall Mounted Heat Pump System
Submittal Data Sheet
General Information
Job Name: [Not Specified]
Tag#: [Not Specified]
Model Numbers: FTX24NMVJU / RX24NMVJU
Product Type: 2-Ton Wall Mounted Heat Pump System
Warranty: 12 Year Parts Limited Warranty (Online registration required within 60 days of installation, except in California or Quebec. 5-year limited warranty for commercial applications.)
More Information: Complete warranty details available from your local dealer or at www.daikincomfort.com.
Efficiency
Cooling | Heating | |||
---|---|---|---|---|
SEER | EER | HSPF | COP | |
18 | 12.5 | 9.0 | 3.50 |
Performance
Cooling (Btu/hr)
- Rated (Min/Max): 21,200 (5,500 / 24,000)
- Sensible @ AHRI: 15,760
- Moisture Removal gal/h: 1.2
- Operating Range: 50°F - 115°F
- Rated Cooling Conditions: Indoor: 80°F DB/67°F WB, Outdoor: 95°F DB/75°F WB
Heating (Btu/hr)
- 1: @ 47° Rated (Min/Ma): 24,000 (5,800 / 27,600)
- 2: @ 17° Rated: 14,400
- 3: @ 5° Max: 10,720
- Operating Range: 5°F - 65°F
- 1: Rated Heating Conditions: Indoor: 70°F DB/60°F WB, Outdoor: 47°F DB/43°F WB
- 2: Rated Heating Conditions: Indoor: 70°F DB/60°F WB, Outdoor: 17°F DB/15°F WB
- 3: Rated Heating Conditions: Indoor: 70°F DB/60°F WB, Outdoor: 5°F DB/5°F WB
Indoor Specifications
Airflow Rate (cfm)
Cooling | Heating | |||
---|---|---|---|---|
H | M | H | M | |
713 | 579 | 745 | 604 | |
L | SL | L | SL | |
512 | 403 | 470 | 420 |
Sound (dBA)
- H/M/L/SL: 53/45/39/34 (Cooling), 53/43/37/34 (Heating)
Dimensions (H x W x D) (in)
- Indoor Unit: 11-5/8 x 39 x 10-3/8
- Weight (Lbs): 27
Outdoor Specifications
- Compressor: Hermetically Sealed Swing Type
- Refrigerant: R-410A
- Refrigerant Oil: PVE (FVC50K)
Airflow Rate (cfm)
Cooling | Heating | |||
---|---|---|---|---|
H | SL | H | SL | |
2,101 | 1,762 | 1,893 | 1,585 |
- Sound Power Level (dBA): 55
- Dimensions (H x W x D) (in): 28-5/16 × 34-1/4 × 12-5/8
- Weight (Lbs): 108
Electrical
208/60/1 | 230/60/1 | |
---|---|---|
System MCA: | 18.3 | 18.3 |
System MFA: | 20 | 20 |
Compressor RLA: | 12.0 | 12.0 |
Outdoor fan motor FLA: | .38 | .38 |
Outdoor fan motor W: | 58 | 58 |
Indoor fan motor FLA: | .30 | .30 |
Indoor fan motor W: | 46 | 46 |
MCA: Min. circuit amps, MFA: Max. fuse amps, FLA: Full load amps, RLA: Rated load amps, W: Fan motor rated output.
Piping
- Liquid (in): 1/4
- Gas (in): 5/8
- Drain (in): 5/8
- Max. Interunit Piping Length (ft): 98.4
- Max. Interunit Height Difference (ft): 65.625
- Chargeless (ft): 32.8
- Additional Charge of Refrigerant (oz/ft): .21
Dimensional Data - Indoor Unit
Wireless Remote Controller: ARC480A8
Dimensions (approximate):
- Width: 39 inches (990mm)
- Height: 11-5/8 inches (295mm)
- Depth: 10-3/8 inches (263mm)
Key Features: Front grille, flaps for airflow direction, signal receiver, operation lamp, timer lamp, indoor temperature thermistor, terminal block, drain hose connection.
Required Space: Minimum 1-15/16 inches (50mm) for maintenance on the right and left, approximately 15-3/4 inches (400mm) above, and approximately 17-5/16 inches (440mm) below.
Piping Connections: Liquid pipe 1/4 inch, Gas pipe 5/8 inch, Drain hose connection.
Wall Hole: Standard locations for wall holes include a 3-1/8 inch (80mm) hole for piping and a 3-1/8 inch (80mm) hole for the wall hole.
Dimensional Data - Outdoor Unit
Dimensions (approximate):
- Width: 34-1/4 inches (870mm)
- Depth: 12-5/8 inches (320mm)
- Height: 29-3/8 inches (746mm)
Key Features: Handle, brand name plate, 4-holes for foundation bolts (M8 or M10), ground terminal, service port, stop valve cover, terminal strip cover, outdoor air thermistor, electric wire intake, drain outlet.
Required Space: Minimum 1-15/16 inches (50mm) for air passage on the sides and rear, and a minimum of 1-3/16 inches (30mm) for air passage on the front.
Piping Connections: Liquid stop valve 1/4 inch, Gas stop valve 5/8 inch, Drain outlet connection.
Wall Height Limitation: Wall height on the air outlet side should be less than 47-1/4 inches (1200mm).
Optional Accessories
Indoor Unit Accessories
Included | Part Number | Description |
---|---|---|
BRP072A43 | Wireless Interface Adapter (S21 Adapter Included) | |
DACA-TS1-1 | Daikin ENVi Intelligent Thermostat Kit (Adaptor Required) | |
BRC944B2-A08 | Wired Remote Controller kit (Adaptor Required) | |
BRCW901A08 | Wired Remote Controller Cord - 8m (Included in above kit) | |
DACA-BRCW901P10 | Remote Controller Cable, Plenum Rated, 10 ft | |
DACA-BRCW901P25 | Remote Controller Cable, Plenum Rated, 25 ft | |
KRP980B2 | Adaptor for wired remote controller (18 & 24) | |
KAF970A45 | Titanium apatite photocatalytic air-purifying filter WITH frame | |
KAF970A46 | Titanium apatite photocatalytic air-purifying filter WITHOUT frame | |
DACA-CP1-1 | Inline Condensate Pump (Fits inside all Daikin wall & floor mount units) | |
DACA-CP4-1 | External Condensate Pump | |
KRP928BB2S + KRP980B2 | Interface adaptor for DIII-NET |
Outdoor Unit Accessories
Included | Part Number | Description |
---|---|---|
DACA-WB-1 | Powder-Coated Wall-Mounted Bracket | |
KPW063A4 | Air direction adjustment grille (18 & 24) | |
KEH063A4E | Daikin BML Drain Pan Heater Large RX18,24 & RXN18,24 | |
KKG063A42 | Back protection wire net (18 & 24) | |
KKG063A43 | Side protection wire net (18 & 24) | |
KKP937A4 | Drain Plug for OD Unit |