Daikin FTX24NMVJU / RX24NMVJU 2-Ton Wall Mounted Heat Pump System
Submittal Data Sheet
General Information
Job Name: [Not Specified]
Tag#: [Not Specified]
Model Numbers: FTX24NMVJU / RX24NMVJU
Product Type: 2-Ton Wall Mounted Heat Pump System
Warranty: Complete warranty details are available from your local dealer or at www.daikincomfort.com. To receive the 12-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Quebec. If the product is installed in a commercial application, the limited warranty period is 5 years.
[Image Description: A Daikin outdoor unit is shown, featuring a prominent "12 YEAR PARTS LIMITED WARRANTY" badge.]
Efficiency
Metric | Cooling | Heating |
---|---|---|
SEER | 18 | - |
EER | 12.5 | - |
HSPF | - | 9.0 |
COP | - | 3.50 |
Performance
Cooling (Btu/hr)
Rated (Min/Max) | 21,200 (5,500 / 24,000) |
Sensible @ AHRI | 15,760 |
Moisture Removal gal/h | 1.2 |
Standard Operating Range | 50°F – 115°F |
Extended Operating Range* | -4°F – 115°F |
Rated Cooling Conditions: | Indoor: 80°F DB/67°F WB Outdoor: 95°F DB/75°F WB |
*With field settings and wind baffle
Heating (Btu/hr)
1: @ 47° Rated (Min/Max) | 24,000 (5,800 / 27,600) |
2: @ 17° Rated | 14,400 |
3: @ 5° | 10,720 |
Operating Range | 5°F – 65°F |
1: Rated Heating Conditions: | Indoor: 70°F DB/60°F WB Outdoor: 47°F DB/43°F WB |
2: Rated Heating Conditions: | Indoor: 70°F DB/60°F WB Outdoor: 17°F DB/15°F WB |
3: Heating Conditions: | Indoor: 70°F DB/60°F WB Outdoor: 5°F DB/5°F WB |
Indoor Specifications
Cooling | Heating | |||
---|---|---|---|---|
H | M | H | M | |
Airflow Rate (cfm) | 713 | 579 | 745 | 604 |
L | SL | L | SL | |
512 | 403 | 470 | 420 | |
Sound (dBA) H / M / L / SL | 53 / 45 / 39 / 34 | |||
Dimensions (H x W x D) (in) | 11-5/8 x 39 x 10-3/8 | |||
Weight (Lbs) | 27 |
Outdoor Specifications
Compressor | Hermetically Sealed Swing Type |
Refrigerant | R-410A |
Factory Charge (Lbs) | 3.20 |
Refrigerant Oil | PVE (FVC50K) |
Cooling | Heating | |||
---|---|---|---|---|
H | SL | H | SL | |
Airflow Rate (cfm) | 2,101 | 1,762 | 1,893 | 1,585 |
Sound Pressure Level (dBA) | 55 | |||
Dimensions (H x W x D) (in) | 28-5/16 x 34-1/4 x 12-5/8 | |||
Weight (Lbs) | 108 |
Electrical
208/60/1 | 230/60/1 | |
---|---|---|
System MCA | 18.3 | 18.3 |
System MFA | 20 | 20 |
Compressor RLA | 12.0 | 12.0 |
Outdoor fan motor FLA | .38 | .38 |
Outdoor fan motor W | 58 | 58 |
Indoor fan motor FLA | .30 | .30 |
Indoor fan motor W | 46 | 46 |
MFA: Max. fuse amps MCA: Min. circuit amps (A) FLA: Full load amps (A) RLA: Rated load amps (A) W: Fan motor rated output (W)
Piping
Liquid (in) | 1/4 |
Gas (in) | 5/8 |
Drain (in) | 5/8 |
Max. Interunit Piping Length (ft) | 98.4 |
Max. Interunit Height Difference (ft) | 65.625 |
Chargeless (ft) | 32.8 |
Additional Charge of Refrigerant (oz/ft) | .21 |
Indoor Unit Dimensional Data
[Diagram Description: The indoor unit is depicted with overall dimensions of 11-5/8 (H) x 39 (W) x 10-3/8 (D) inches. The front panel features a grille with adjustable flaps for airflow direction. Key control elements visible or indicated include the signal receiver, operation lamp, timer lamp, indoor unit on/off switch, and room temperature thermistor. Blade angles for automatic up/down airflow control in cooling, dry, and heating modes, as well as manual right/left control, are illustrated. Connection points for the gas pipe (5/8 inch O.D.), liquid pipe (1/4 inch O.D.), and drain hose (5/8 inch O.D.) are shown. The diagram also details the mounting plate, terminal block with earth terminal, and general rating name plate. Required clearances for maintenance (minimum 1-15/16 inches or 50mm) and air passage are indicated, along with standard wall hole locations for embedded piping (2-3/8 inch or 60mm) and general use (3-1/8 inch or 80mm).]
Overall Dimensions (H x W x D): 11-5/8 x 39 x 10-3/8 inches
Control Panel Features: Wireless Remote Controller (ARC480A8), Signal Transmitter, Signal Receiver, Operation Lamp, Timer Lamp, Indoor Unit On/Off Switch, Room Temp. Thermistor.
Airflow Direction Control:
- Up/Down (Automatic): Illustrated angles for Cooling, Dry, Heating modes.
- Right/Left (Manual): Illustrated angles for Fan mode.
Connections:
- Gas Pipe: 5/8 inch (O.D. 16mm)
- Liquid Pipe: 1/4 inch (O.D. 6.4mm)
- Drain Hose: (Connecting Part I.D. 9/16 inch / 14mm, O.D. 5/8 inch / 16mm)
Mounting: Includes mounting plate, terminal block with earth terminal, and general rating name plate.
Clearances: Minimum 1-15/16 inches (50mm) for maintenance, and space for performance.
Wall Hole: Standard locations for wall holes are indicated, including for embedded piping (2-3/8 inch or 60mm) and general use (3-1/8 inch or 80mm).
Outdoor Unit Dimensional Data
[Diagram Description: The outdoor unit is illustrated with its overall dimensions. Prominent connection points include a service port, ground terminal, gas stop valve (5/8 inch / 15.9mm CuT), liquid stop valve (1/4 inch / 6.4mm CuT), and a drain outlet designed for connection with a drain joint. The unit is equipped with a handle and features four holes for foundation bolts (M8 or M10). An electric wire intake is visible, along with the outdoor air thermistor and the manufacturer's label. Minimum space requirements for air passage are shown, and a note specifies that the wall height on the air outlet side should be less than 47-1/4 inches (1200mm).]
Overall Dimensions: Approximately 34-1/4 (H) x 28-15/16 (W) x 13-3/4 (D) inches.
Connections:
- Service Port
- Ground Terminal
- Gas Stop Valve: 5/8 inch (15.9mm) CuT
- Liquid Stop Valve: 1/4 inch (6.4mm) CuT
- Drain Outlet: For connection with drain joint (I.D. 5/8 inch / 15.9mm hose)
Mounting: Features a handle, 4-holes for foundation bolts (M8 or M10), and electric wire intake.
Components: Outdoor Air Thermistor, Manufacturer's Label.
Clearances: Minimum space for air passage is indicated. Wall height on the air outlet side should be less than 47-1/4 inches (1200mm).
Optional Accessories
Indoor Unit Accessories
Included | Part Number | Description |
---|---|---|
BRP072A43 | Wireless Interface Adapter (S21 Adapter Included) | |
BRC944B2-A08 | Wired Remote Controller kit (Adaptor Required) | |
BRCW901A08 | Wired Remote Controller Cable – 25ft (Included in above kit) | |
BRCW901A03 | Wired Remote Controller Cable – 10ft | |
KRP980B2 | Adaptor for wired remote controller (18 & 24) | |
KAF970A45 | Titanium apatite photocatalytic air-purifying filter WITH frame | |
KAF970A46 | Titanium apatite photocatalytic air-purifying filter WITHOUT frame | |
DACA-CP1-1 | Inline Condensate Pump (Fits inside all Daikin wall & floor mount units) | |
DACA-CP4-1 | External Condensate Pump | |
KRP928BB2S + KRP980B2 | Interface adaptor for DIII-NET |
Outdoor Unit Accessories
Included | Part Number | Description |
---|---|---|
DACA-WB-1 | Powder-Coated Wall-Mounted Bracket | |
KPW063A4 | Air direction adjustment grille (18 & 24) | |
KEH063A4E | Daikin BML Drain Pan Heater Large RX18,24 & RXN18,24 | |
KKG063A42 | Back protection wire net (18 & 24) | |
KKP937A4 | Drain Plug for OD Unit |
Daikin North America LLC 5151 San Felipe, Suite 500 Houston, TX 77056
(Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations)
Submittal Revision Date: September 2018