Daikin FTX24NMVJU / RX24NMVJU 2-Ton Wall Mounted Heat Pump System

Submittal Data Sheet

General Information

Job Name: [Not Specified]

Tag#: [Not Specified]

Model Numbers: FTX24NMVJU / RX24NMVJU

Product Type: 2-Ton Wall Mounted Heat Pump System

Warranty: Complete warranty details are available from your local dealer or at www.daikincomfort.com. To receive the 12-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Quebec. If the product is installed in a commercial application, the limited warranty period is 5 years.

[Image Description: A Daikin outdoor unit is shown, featuring a prominent "12 YEAR PARTS LIMITED WARRANTY" badge.]

Efficiency

Metric Cooling Heating
SEER 18 -
EER 12.5 -
HSPF - 9.0
COP - 3.50

Performance

Cooling (Btu/hr)

Rated (Min/Max)21,200 (5,500 / 24,000)
Sensible @ AHRI15,760
Moisture Removal gal/h1.2
Standard Operating Range50°F – 115°F
Extended Operating Range*-4°F – 115°F
Rated Cooling Conditions:Indoor: 80°F DB/67°F WB
Outdoor: 95°F DB/75°F WB

*With field settings and wind baffle

Heating (Btu/hr)

1: @ 47° Rated (Min/Max)24,000 (5,800 / 27,600)
2: @ 17° Rated14,400
3: @ 5°10,720
Operating Range5°F – 65°F
1: Rated Heating Conditions:Indoor: 70°F DB/60°F WB
Outdoor: 47°F DB/43°F WB
2: Rated Heating Conditions:Indoor: 70°F DB/60°F WB
Outdoor: 17°F DB/15°F WB
3: Heating Conditions:Indoor: 70°F DB/60°F WB
Outdoor: 5°F DB/5°F WB

Indoor Specifications

Cooling Heating
H M H M
Airflow Rate (cfm)713579745604
LSLLSL
512403470420
Sound (dBA) H / M / L / SL53 / 45 / 39 / 34
Dimensions (H x W x D) (in)11-5/8 x 39 x 10-3/8
Weight (Lbs)27

Outdoor Specifications

CompressorHermetically Sealed Swing Type
RefrigerantR-410A
Factory Charge (Lbs)3.20
Refrigerant OilPVE (FVC50K)
Cooling Heating
H SL H SL
Airflow Rate (cfm)2,1011,7621,8931,585
Sound Pressure Level (dBA)55
Dimensions (H x W x D) (in)28-5/16 x 34-1/4 x 12-5/8
Weight (Lbs)108

Electrical

208/60/1 230/60/1
System MCA18.318.3
System MFA2020
Compressor RLA12.012.0
Outdoor fan motor FLA.38.38
Outdoor fan motor W5858
Indoor fan motor FLA.30.30
Indoor fan motor W4646

MFA: Max. fuse amps MCA: Min. circuit amps (A) FLA: Full load amps (A) RLA: Rated load amps (A) W: Fan motor rated output (W)

Piping

Liquid (in)1/4
Gas (in)5/8
Drain (in)5/8
Max. Interunit Piping Length (ft)98.4
Max. Interunit Height Difference (ft)65.625
Chargeless (ft)32.8
Additional Charge of Refrigerant (oz/ft).21

Indoor Unit Dimensional Data

[Diagram Description: The indoor unit is depicted with overall dimensions of 11-5/8 (H) x 39 (W) x 10-3/8 (D) inches. The front panel features a grille with adjustable flaps for airflow direction. Key control elements visible or indicated include the signal receiver, operation lamp, timer lamp, indoor unit on/off switch, and room temperature thermistor. Blade angles for automatic up/down airflow control in cooling, dry, and heating modes, as well as manual right/left control, are illustrated. Connection points for the gas pipe (5/8 inch O.D.), liquid pipe (1/4 inch O.D.), and drain hose (5/8 inch O.D.) are shown. The diagram also details the mounting plate, terminal block with earth terminal, and general rating name plate. Required clearances for maintenance (minimum 1-15/16 inches or 50mm) and air passage are indicated, along with standard wall hole locations for embedded piping (2-3/8 inch or 60mm) and general use (3-1/8 inch or 80mm).]

Overall Dimensions (H x W x D): 11-5/8 x 39 x 10-3/8 inches

Control Panel Features: Wireless Remote Controller (ARC480A8), Signal Transmitter, Signal Receiver, Operation Lamp, Timer Lamp, Indoor Unit On/Off Switch, Room Temp. Thermistor.

Airflow Direction Control:

  • Up/Down (Automatic): Illustrated angles for Cooling, Dry, Heating modes.
  • Right/Left (Manual): Illustrated angles for Fan mode.

Connections:

  • Gas Pipe: 5/8 inch (O.D. 16mm)
  • Liquid Pipe: 1/4 inch (O.D. 6.4mm)
  • Drain Hose: (Connecting Part I.D. 9/16 inch / 14mm, O.D. 5/8 inch / 16mm)

Mounting: Includes mounting plate, terminal block with earth terminal, and general rating name plate.

Clearances: Minimum 1-15/16 inches (50mm) for maintenance, and space for performance.

Wall Hole: Standard locations for wall holes are indicated, including for embedded piping (2-3/8 inch or 60mm) and general use (3-1/8 inch or 80mm).

Outdoor Unit Dimensional Data

[Diagram Description: The outdoor unit is illustrated with its overall dimensions. Prominent connection points include a service port, ground terminal, gas stop valve (5/8 inch / 15.9mm CuT), liquid stop valve (1/4 inch / 6.4mm CuT), and a drain outlet designed for connection with a drain joint. The unit is equipped with a handle and features four holes for foundation bolts (M8 or M10). An electric wire intake is visible, along with the outdoor air thermistor and the manufacturer's label. Minimum space requirements for air passage are shown, and a note specifies that the wall height on the air outlet side should be less than 47-1/4 inches (1200mm).]

Overall Dimensions: Approximately 34-1/4 (H) x 28-15/16 (W) x 13-3/4 (D) inches.

Connections:

  • Service Port
  • Ground Terminal
  • Gas Stop Valve: 5/8 inch (15.9mm) CuT
  • Liquid Stop Valve: 1/4 inch (6.4mm) CuT
  • Drain Outlet: For connection with drain joint (I.D. 5/8 inch / 15.9mm hose)

Mounting: Features a handle, 4-holes for foundation bolts (M8 or M10), and electric wire intake.

Components: Outdoor Air Thermistor, Manufacturer's Label.

Clearances: Minimum space for air passage is indicated. Wall height on the air outlet side should be less than 47-1/4 inches (1200mm).

Optional Accessories

Indoor Unit Accessories

Included Part Number Description
BRP072A43Wireless Interface Adapter (S21 Adapter Included)
BRC944B2-A08Wired Remote Controller kit (Adaptor Required)
BRCW901A08Wired Remote Controller Cable – 25ft (Included in above kit)
BRCW901A03Wired Remote Controller Cable – 10ft
KRP980B2Adaptor for wired remote controller (18 & 24)
KAF970A45Titanium apatite photocatalytic air-purifying filter WITH frame
KAF970A46Titanium apatite photocatalytic air-purifying filter WITHOUT frame
DACA-CP1-1Inline Condensate Pump (Fits inside all Daikin wall & floor mount units)
DACA-CP4-1External Condensate Pump
KRP928BB2S + KRP980B2Interface adaptor for DIII-NET

Outdoor Unit Accessories

Included Part Number Description
DACA-WB-1Powder-Coated Wall-Mounted Bracket
KPW063A4Air direction adjustment grille (18 & 24)
KEH063A4EDaikin BML Drain Pan Heater Large RX18,24 & RXN18,24
KKG063A42Back protection wire net (18 & 24)
KKP937A4Drain Plug for OD Unit

Daikin North America LLC 5151 San Felipe, Suite 500 Houston, TX 77056

(Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations)

Submittal Revision Date: September 2018

PDF preview unavailable. Download the PDF instead.

Daikin Submittal Data Form 205 FTX24NMVJU-RX24NMVJU CSUpdatesv10 Nuance PDF Create

Related Documents

Preview Daikin FTX24NMVJU / RX24NMVJU 2-Ton Wall Mounted Heat Pump System Specifications
Comprehensive submittal data sheet detailing the specifications, performance, dimensions, electrical requirements, and optional accessories for the Daikin FTX24NMVJU / RX24NMVJU 2-Ton Wall Mounted Heat Pump System.
Preview Daikin FTX24NMVJURX24NMVJU 2.0-Ton Wall Mounted Unit Submittal Data Sheet
Technical specifications and performance data for the Daikin 2.0-Ton Wall Mounted Unit, model FTX24NMVJURX24NMVJU, detailing features, benefits, system performance, and dimensional information for both indoor and outdoor units.
Preview Daikin 2.0-Ton Wall Mounted Unit FTX24NMVJURX24NMVJU Submittal Data Sheet
Comprehensive submittal data sheet for the Daikin 2.0-Ton Wall Mounted Unit (FTX24NMVJURX24NMVJU), detailing features, benefits, system performance specifications, and dimensional information for indoor and outdoor units.
Preview Daikin FTX24NMVJU / RX24NMVJU 2-Ton Wall Mounted Heat Pump System Specifications
Detailed submittal data sheet for the Daikin FTX24NMVJU / RX24NMVJU 2-Ton Wall Mounted Heat Pump System, including efficiency, performance, electrical, piping, and optional accessory specifications.
Preview Daikin 2.0-Ton Wall Mounted Unit FTX24NMVJURX24NMVJU Submittal Data Sheet
Technical specifications and submittal data for the Daikin 2.0-Ton Wall Mounted Unit (FTX24NMVJURX24NMVJU), including features, benefits, system performance, and dimensional drawings.
Preview Daikin FTX24NMVJU / RX24NMVJU 2-Ton Wall Mounted Heat Pump System Submittal Data Sheet
Detailed submittal data sheet for the Daikin FTX24NMVJU / RX24NMVJU 2-Ton Wall Mounted Heat Pump System, including specifications, performance data, electrical requirements, and piping information.
Preview Daikin FTX24NMVJU / RX24NMVJU 2-Ton Wall Mounted Heat Pump System Submittal Data Sheet
Detailed submittal data sheet for the Daikin FTX24NMVJU / RX24NMVJU 2-Ton Wall Mounted Heat Pump System, including efficiency, performance, electrical, and piping specifications, along with dimensional data and optional accessories.
Preview Daikin FTX/RXL Series Wall Mounted Heat Pump Specifications
Comprehensive submittal data for Daikin's FTX/RXL series wall-mounted heat pump systems, detailing specifications, performance metrics, and operational ranges for models FTX09NMVJU, RXL09QMVJU, FTX12NMVJU, RXL12QMVJU, FTX15NMVJU, and RXL15QMVJU.