Daikin FTX24NMVJU / RX24NMVJU 2-Ton Wall Mounted Heat Pump System
Submittal Data Sheet
Overview and Warranty
This document provides submittal data for the Daikin FTX24NMVJU / RX24NMVJU 2-Ton Wall Mounted Heat Pump System.
Warranty Information: Complete warranty details are available from your local dealer or at www.daikincomfort.com. To receive the 12-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Quebec. For commercial applications, the limited warranty period is 5 years.
Note: MFA: Maximum fuse amps, MCA: Minimum circuit amps (A), FLA: Full load amps (A), RLA: Rated load amps (A), W: Fan motor rated output (W).
Piping Specifications
Parameter
Value
Liquid (in)
1/4
Gas (in)
5/8
Drain (in)
5/8
Max. Interunit Piping Length (ft)
98.4
Max. Interunit Height Difference (ft)
65.625
Chargeless (ft)
32.8
Additional Charge of Refrigerant (oz/ft)
.21
Dimensional Data - Indoor Unit (FTX24NMVJU)
Diagram Description: The indoor unit diagram shows the unit's front, side, and bottom views. It details the location of the signal receiver, operation lamp, timer lamp, indoor unit on/off switch, room temperature thermistor, terminal block, and drain hose connection. It also illustrates the adjustable flaps for airflow direction control, showing angles for up/down movement (automatic) and right/left movement (manual). Mounting plate dimensions and wall hole requirements are also depicted.
Dimensions (approximate):
Width: 39 inches (990mm)
Height: 11-5/8 inches (295mm)
Depth: 10-3/8 inches (263mm)
Piping Connections: Liquid line: 1/4 inch (6.4mm) Copper Tubing. Gas line: 5/8 inch (15.9mm) Copper Tubing. Drain hose: I.D. 9/16 inch (14mm), O.D. 5/8 inch (16mm).
Wall Hole: Standard locations for wall holes are shown, including a 2-3/8 inch (60mm) hole for embedded piping and a 3-1/8 inch (80mm) hole.
Dimensional Data - Outdoor Unit (RX24NMVJU)
Diagram Description: The outdoor unit diagram presents front, side, and top views. It highlights the handle, brand name plate, foundation bolt holes (M8 or M10), ground terminal, service port, stop valve cover, terminal strip cover, liquid and gas stop valves, drain outlet, electric wire intake, and outdoor air thermistor. The outdoor air thermistor location is shown. Crucial clearances for air passage and maintenance are specified. It also indicates the wall height limitation on the air outlet side.
Dimensions (approximate):
Width: 28-15/16 inches (735mm)
Depth: 12-5/8 inches (320mm)
Height: 23-5/8 inches (600mm)
Piping Connections: Liquid stop valve: 1/4 inch (6.4mm) Copper Tubing. Gas stop valve: 5/8 inch (15.9mm) Copper Tubing. Drain outlet: For connection with drain joint, I.D. 5/8 inch (15.9mm) hose.
Daikin FTX24NMVJURX24NMVJU 2.0-Ton Wall Mounted Unit Submittal Data Sheet Technical specifications and performance data for the Daikin 2.0-Ton Wall Mounted Unit, model FTX24NMVJURX24NMVJU, detailing features, benefits, system performance, and dimensional information for both indoor and outdoor units.
Daikin 2.0-Ton Wall Mounted Unit FTX24NMVJURX24NMVJU Submittal Data Sheet Comprehensive submittal data sheet for the Daikin 2.0-Ton Wall Mounted Unit (FTX24NMVJURX24NMVJU), detailing features, benefits, system performance specifications, and dimensional information for indoor and outdoor units.