UNI-T UTi720E/UTi730E Professional Thermal Imager User Manual

Preface

Thank you for selecting the UNI-T E Series Infrared Thermal Imaging Device. Please read this manual carefully before use, especially the section on "Safety Precautions". Keep this manual with the device for future reference.

Limited Warranty and Liability

Uni-Trend guarantees the product against defects in material and workmanship for one year from the purchase date. This warranty excludes damage from accident, negligence, misuse, modification, contamination, or improper handling. Uni-Trend is not liable for special, indirect, incidental, or consequential damages. Some regions may not allow these limitations.

Please remove the battery pack and charge it separately for optimal charging efficiency.

Contents

  • 1. Performance indicators
  • 2. Structure
  • 3. Display instructions
  • 4. Power on-off
  • 5. Instruction of configuration menu
  • 6. Marking tool
  • 7. Image mode
  • 8. Swatches switching
  • 9. Temperature measuring tool
  • 10. Vitta tool
  • 11. Photo view and edit
  • 12. Digital amplification & fusion ratio adjustment
  • 13. System setup
    • 13.1 Camera mode
    • 13.2 Units
    • 13.3 Parameters
    • 13.4 Alarm
    • 13.5 QR CODE
    • 13.6 Language
    • 13.7 Date and time
    • 13.8 Wi-Fi
    • 13.9 USB mode
    • 13.10 Brightness
    • 13.11 Automatic Shutdown
    • 13.12 Factory reset
    • 13.13 Formatting
    • 13.14 About
  • 14. SD Card
  • 15. Maintain
  • 16. Safety precautions
  • 17. FCC Compliance statement
  • 18. Common emissivity table

1. Performance indicators

UTi720E:

  • Mode: Low temperature scale (-20°C~150°C), High temperature scale (0°C~550°C) (manual selection)
  • Thermal imaging pixel: 256*192 (49152)
  • IFOV: 3.8mrad
  • Focal length: 3.2mm
  • Sensitivity: <50mK @25°C
  • Frame frequency: <25Hz
  • Precision: -10°C~550°C, room temperature of 25°C, and ±2°C/±2% to take the maximum value
  • Temperature measurement scale: -20°C~550°C (-4°F~1022°F)

UTi730E:

  • Mode: Automatic gain
  • Thermal imaging pixel: 320*240 (76800)
  • IFOV: 3mrad
  • Focal length: 4.0mm
  • Sensitivity: <65mK @25°C
  • Frame frequency: 9Hz
  • Precision: -10°C~400°C, room temperature of 25°C, and ±2°C/±2% to take the maximum value
  • Temperature measurement scale: -40°C~400°C (-40°F~752°F)

UTi720E/UTi730E:

  • Sensor: Un-cooled vanadium oxide
  • Display resolution: 640*480
  • Emissivity: 0.95 (default) 0.01~1.00
  • Visible light pixel: 2 million
  • Thermal imaging pixel size: 12μm

2. Structure

The device has the following components:

  • 1. USB Type-C interface
  • 2. Upper casing
  • 3. Lower casing
  • 4. SD card slot
  • 5. Interface protection cover
  • 6. LCD display
  • 7. Start key
  • 8. Lighting key
  • 9. Left key
  • 10. Up key
  • 11. Photo browsing button
  • 12. Back key
  • 13. Right key
  • 14. SET key
  • 15. Down key
  • 16. Bracket fixed screw hole
  • 17. Infrared thermal image window
  • 18. Lamp
  • 19. Visible light camera window
  • 20. Photo trigger key

3. Display instructions

The display resolution is 640x480. The screen shows temperature readings, markup tools, and other relevant information.

Markup tools include:

  • Center point
  • High/low temperature tracking
  • Temperature display
  • Marking tool
  • Image mode
  • Swatches switch
  • Temperature measuring tool
  • Vitta tool
  • System setup
  • Lower limit of swatches scale
  • Upper limit of swatches scale
  • Electric quantity
  • Temperature of the measurement central point
  • Automatic tracking of the maximum point
  • Automatic tracking of the minimum point
  • Temperature measurement central point

4. Power on-off

To turn on: Long press the "Power button" for 5 seconds.

To turn off: Long press the "Power button" for 5 seconds.

The device will automatically shut down if the battery is low.

5. Instruction of configuration menu

Access the main menu by pressing the "SET key" on the home page. Use the "Left/right key" to navigate between sub-menus and "SET key" to enter a selected sub-menu. Use "Left/right key" to select settings within a sub-menu, and "SET key" to confirm. Press the "Back key" to return to the previous level or save settings.

Main menu options: Camera mode, Units, Parameters, HI/LO Alert, QR CODE, Language, Settings.

Sub-menu options typically include: Single Shot, Time-lapse, Temperature, Distance, etc.

6. Marking tool

Use the "SET key" to access the main menu, then select "Marking tool". Use the "Left/right key" to choose options like "Center point". Press "SET key" to activate or deactivate the marking tool. The "Center point" cursor appears when activated.

7. Image mode

Access the "Image mode" option from the main menu. Select from "Thermal imaging", "Visible light", "Fusion", and "Picture in picture". In "Fusion" mode, adjust the fusion ratio and distance. In "Picture in picture" mode, adjust position and size. The "QR code" option allows manual entry or scanning of QR codes.

8. Swatches switching

From the main menu, select "Swatches Switch". Use the "Left/right key" to choose from seven available swatches: white hot, red hot, iron red, black hot, high rainbow, lava, and rainbow.

9. Temperature measuring tool

Select "Temperature measuring tool" from the main menu. Choose analysis objects like point, line, rectangle, or circle. Use "Left/right key" to select the target. Functions include select, move, stretch, compare, and delete. Temperature information is displayed on the left. For line analysis, a temperature curve is shown in the lower left corner.

Note: Up to five point, one line, and three rectangle/circle analysis objects can be added. The total number of objects cannot exceed six.

10. Vitta tool

Access "Vitta Tool" from the main menu. Select from six isothermal modes: Auto, Proportional, Down, Up, Interval, and Manual.

Pressing "SET key" can clear all analysis objects. You can save or load preset tools.

11. Photo view and edit

Enter the multimedia view by pressing the "Photo view key". Use "Up/Down key" to select photos/videos. Press "SET key" to view a picture and use "Left/right key" to switch between them.

The picture interface sub-menu allows editing of photo messages, including shooting time, emissivity, infrared resolution, remarks, and QR code. You can also perform second editing of marking tools, image modes, swatches, temperature measurement tools, and vitta tools.

12. Digital amplification & fusion ratio adjustment

Use the "Up key" to enlarge the screen, with magnification factors displayed in the upper right corner (1X, 2X, 4X). Use "Left/right key" to adjust the fusion ratio (0%-100%).

After editing, press "SET key" to open the status editing sub-menu. You can "Recover" to restore the original state, "Exit" without saving, or "Save" changes (either "Cover" the original or save as "New").

13. System setup

Access "System setup" from the main menu. Use "Up/Down key" to select settings like Camera mode, Units, Parameters, Alarm, QR CODE, Language, Date and time, Wi-Fi, USB mode, Brightness, Automatic Shutdown, Factory reset, and About. Press "SET key" to enter sub-menus for adjustments.

13.1 Camera mode

Select "Camera mode" from the Settings menu. Choose between "Single Shot" and "Time-lapse" (with adjustable interval).

13.2 Units

Select "Units" from the Settings menu. Adjust temperature units (°C, K, °F). Distance units cannot be changed.

13.3 Parameters

Select "Parameter" from the Settings menu. Adjust emissivity, ambient temperature, reflected temperature, relative humidity, object distance, and temperature scale.

  • UTi720E: Low temperature scale: -20°C~150°C, High temperature scale: 0~550°C.
  • UTi730E: Object distance parameter adjustment is available.

13.4 Alarm

Select "Alarm" from the Settings menu. Configure high temperature alarm, low temperature alarm, and LED alarm. Set alarm values using "Up/Down key". When temperature exceeds the set high alarm value, a red triangle appears. When below the low alarm value, a green triangle appears.

13.5 QR CODE

Select "QR CODE" from the Settings menu. Manage QR codes, including changing names, resetting, and classifying pictures by QR code.

13.6 Language

Select "Language" from the Settings menu. Choose from English, French, German, Spanish, or Russian.

13.7 Date and time

Select "Date and Time" from the Settings menu. Adjust time format, date, and time using "Up/Down" and "Left/Right keys".

13.8 Wi-Fi

Select "Wi-Fi" from the Settings menu. Enable the hotspot, and set the Hotspot ID and password.

13.9 USB mode

Select "USB mode" from the Settings menu. Choose between "USB storage" and "USB Projection".

13.10 Brightness

Select "Brightness" from the Settings menu. Adjust screen brightness from 1 to 100.

13.11 Automatic Shutdown

Select "Automatic Shutdown" from the Settings menu. Choose from Off, 5, 10, 20, 30, 45, 60, or 90 minutes.

13.12 Factory reset

Select "Factory reset" from the Settings menu. Confirm to reset the device to factory settings. The device will shut down and restore settings upon manual restart.

13.13 Formatting

Select "Formatting" from the Settings menu. If an SD card is present, confirm to format it. If no SD card is detected, an "Unknown" message will appear.

13.14 About

Select "About" from the Settings menu to view product information, including model, thermal resolution, hardware version, system version, SN, and SD capacity.

14. SD Card

The device supports microSD cards for image storage. Periodically copy backup data and clear the card to maintain operating speed. Avoid hot-swapping the SD card. If removed during viewing, a "SD card is lost" message will appear.

15. Maintain

Clean the housing with a damp cloth or mild soapy solution. Do not use grinders, isopropyl alcohol, or solvents on the lens/window.

16. Safety precautions

Read instructions carefully for accurate measurements. Do not use the device in flammable, explosive, humid, or corrosive environments. Do not use if damaged. Obtain actual temperature by referring to radiation coefficient information; otherwise, measurements may be inaccurate.

Avoid aiming the lens at bright light sources like the sun to prevent damage to the lens or detector. Do not use in extreme temperatures, dust, or high humidity. Refer to the product parameter table for specific environmental requirements.

The system supports USB charging. For improved efficiency, remove and charge the battery pack separately.

17. FCC Compliance statement

This device complies with Part 15 of the FCC Rules. Operation is subject to two conditions: no harmful interference, and acceptance of any received interference. Unauthorized modifications may void the user's authority to operate the equipment.

This equipment has been tested and found to comply with the limits for a Class A digital device. These limits are designed to provide reasonable protection against harmful interference in a commercial environment. If operated in a residential area, it may cause interference, requiring the user to correct it at their own expense.

18. Common emissivity table

A table listing common materials and their corresponding emissivity values is provided for reference.

  • Wood: 0.85
  • Water: 0.96
  • Brick: 0.75
  • Stainless steel: 0.14
  • Tape: 0.96
  • Aluminum plate: 0.09
  • Copper plate: 0.06
  • Black aluminum: 0.95
  • Human skin: 0.98
  • Asphalt: 0.96
  • PVC: 0.93
  • Black paper: 0.86
  • Polycarbonate: 0.8
  • Concrete: 0.97
  • Copper oxide: 0.78
  • Cast iron: 0.81
  • Rust: 0.8
  • Gypsum: 0.75
  • Paint: 0.9
  • Rubber: 0.95
  • Soil: 0.93

For more information, visit www.uni-trend.com.

Models: UTi720E, UTi730E, UTi720E Professional Thermal Imager, UTi720E, Professional Thermal Imager, Thermal Imager, Imager

File Info : application/pdf, 12 Pages, 12.17MB

PDF preview unavailable. Download the PDF instead.

UTi720EUTi730E-User-Manual

References

CorelDRAW Corel PDF Engine Version 14.0.0.701

Related Documents

Preview UNI-T UTi720E/UTi730E Professional Thermal Imager User Manual
Comprehensive user manual for the UNI-T UTi720E and UTi730E Professional Thermal Imagers, detailing features, operation, system setup, maintenance, and safety precautions.
Preview UNI-T UTi85A Professional Thermal Imager User Manual
User manual for the UNI-T UTi85A Professional Thermal Imager, detailing its features, operation, safety guidelines, specifications, and maintenance.
Preview UNI-T UTi165A+ Thermal Imager User Manual - Operation and Specifications
This user manual provides comprehensive instructions for operating the UNI-T UTi165A+ Professional Thermal Imager. It covers safety precautions, device structure, display functions, menu navigation, settings, image capture and viewing, specifications, maintenance, and common emissivity values.
Preview UNI-T UTi260E Professional Thermal Imager User Manual
Comprehensive user manual for the UNI-T UTi260E Professional Thermal Imager, detailing its features, specifications, operation, safety guidelines, and maintenance procedures.
Preview UTi260B Professional Thermal Imager User Manual
This user manual provides comprehensive instructions for operating the UTi260B Professional Thermal Imager, covering specifications, features, measurement functions, settings, and safety guidelines.
Preview UNI-T UTi85A Professional Thermal Imager User Manual
User manual for the UNI-T UTi85A Professional Thermal Imager, detailing its features, operation, specifications, and maintenance.
Preview UNI-T UTi165K Professional Thermal Imager User Manual
Comprehensive user manual for the UNI-T UTi165K Professional Thermal Imager, detailing its features, operation, safety guidelines, specifications, and maintenance. Includes instructions on image capture, viewing, settings, and connectivity.
Preview UNI-T UTi32 Thermal Imager User Manual
User manual for the UNI-T UTi32 Thermal Imager, covering technical specifications, product structure, operation, settings, and safety instructions.