Dear user,

Thank you for selecting the brand new UNI-T E Series Infrared Thermal Imaging Device. In order to use this product correctly, please read the full text of this manual carefully before using, especially the part about "Safety Precautions".

If you have read the full text of this manual, it is recommended to keep this manual properly with the accessories of the thermal imaging device or in a place where you can refer to it at any time for future use.

Limited warranty and limited liability

Our company guarantees that the product is free from defects in material and workmanship for one year from the date you purchase it. For the warranty, it does not cover the damage caused by accident, negligence, misuse, modification, contamination or abnormal operation or handling etc. The Distributor shall not be entitled to give any other guarantee in the name of the Company. If you need warranty service during the warranty period, please contact the authorized service center nearby to obtain the product returning authorization information; and then send the product to the service center with the product problem description.

This guarantee is the only compensation you can get. Otherwise, the Company does not provide any warranty, express or implied, like the implied warranty for the particular purpose. Meanwhile, the Company shall not be liable for any special, indirect, incidental or consequential damage or loss arising out of any cause or conjecture whatsoever. For some states or countries do not allow limitations on implied warranties and incidental or consequential damages, the above limitations and requirements may not apply to you.

1. Performance indicators

UTi720E:

ModeLow temperature scale (-20℃~ 150℃)
High temperature scale (0℃~ 550℃ (manual selecting scale)
Thermal imaging pixel256*192 (49152)
IFOV3.8mrad
Focal length3.2mm
Sensitivity<50mK @25℃
Frame frequency<25Hz
Precision-10℃~550℃, room temperature of 25°C, and ±2°C/±2% to take the maximum value
Temperature measurement scale-20°C ~ 550°C (-4°F~1022°F)

UTi730E:

ModeAutomatic gain
Thermal imaging pixel320*240 (76800)
IFOV3mrad
Focal length4.0mm
Sensitivity<65mK @25°C
Frame frequency9Hz
Precision-10℃~400°C, room temperature of 25°C, and ±2°C/±2% to take the maximum value
Temperature measurement scale-40°C~400°C (-40°F~752°F)

UTi720E/UTi730E:

SensorUn-cooled vanadium oxide
Display resolution640*480
Emissivity0.95 (default) 0.01~1.00
Visible light pixel2 million
Thermal imaging pixel size12μm
SwatchesIron red, rainbow, black heat, white heat, red heat, lava, and high contrast rainbow
Infrared spectral bandwidth8~14μm
Field of viewHFOV 56°

2. Structure

The device has various components labeled with numbers. The following table describes each part:

No.DescriptionNo.Description
1The USB Type-C interface11Photo browsing button
2Upper casing12Back key
3Lower casing13Right key
4SD card slot14SET key
5Interface protection cover15Down key
6LCD display16Bracket fixed screw hole
7Start key17Infrared thermal image window
8Lighting key18Lamp
9Left key19Visible light camera window
10Up key20Photo trigger key

3. Display instructions

The display resolution is 640x480. The screen shows various indicators and tools:

No.DescriptionNo.Description
1Marking tool8Automatic tracking of the minimum point
2Image mode9Color temperature bar
3Swatches switch10Upper limit of swatch scale
4Temperature measuring tool11Electric quantity (battery indicator)
5Vitta tool12Temperature of the measurement central point
6System setup13Automatic tracking of the maximum point
7Lower limit of swatch scale14Temperature measurement central point

4. Power on-off

To turn on the device, long press the "Power button" for 5 seconds. If the device has not been used for a long time or the measurement environment has changed, it may take up to 30 minutes for it to be ready for temperature measurement.

To turn off the device, long press the "Power button" for 5 seconds. A low power reminder will appear when the battery is low. The device needs to be turned off to charge. If the device remains in low power mode, it will automatically shut down.

5. Instruction of configuration menu

The device features a main menu and sub-menus for configuration. To access the main menu, press the "SET key" on the home page. Use the "Left/right key" to select sub-menus and the "SET key" to enter them. Use "Left/right key" to select sub-menu settings, and "SET key" to confirm. Press the "Back key" to return to the previous level and save settings, or press it again to return to the home page.

The main menu allows access to various functions, and sub-menus provide specific settings for options like Camera mode, Units, Parameters, Alarm, QR CODE, Language, Date and time, Wi-Fi, USB mode, Brightness, Automatic Shutdown, Factory reset, and About.

6. Marking tool

To use temperature tracking or display functions (center point, high/low temperature), press the "SET key" to open the main menu. Select "Marking tool" using the "Left/right key" and press "SET key" to enter its sub-menu. Use the "Left/right key" to select options like "Center point". When the center point cursor appears (indicated by crosshairs), the function is active. Pressing "SET key" again will deactivate it.

7. Image mode

From the main menu, select "Image mode" using the "Left/right key" and press "SET key" to access image mode options. You can switch between different modes like "Thermal imaging", "Fusion", and "Picture in picture". In "Fusion mode", the fusion ratio can be adjusted using the "Left/right key", and fusion distance with the "Up/down key". In "Picture in picture mode", the position and size can be adjusted via "Move" or "Stretch" options using the "Left/right key". The "QR code" option allows manual entry or scanning of QR codes.

8. Swatches switching

In the main menu, select "Swatches Switch" using the "Left/right key". Choose from seven available swatches: white hot, red hot, iron red, black hot, high rainbow, lava, and rainbow.

9. Temperature measuring tool

From the main menu, select "Temperature measuring tool" using the "Left/right key". You can select analysis object types such as point, line, rectangle, and circle measurements. These can be added to the home page. The tool allows clearing all functions or using preset tools. Pressing "SET key" adds measurement objects. A sub-menu "Select the target" appears, offering functions like select, move, stretch (for point measurements), compare (for point measurements), and delete. Temperature information is displayed on the left. For line measurements, a temperature curve is shown in the lower left corner.

After clearing functions, you can save current analysis objects as preset tools by selecting "Save Tool" and pressing "OK". If no objects are present, selecting "Read Tool" will load previously saved presets.

Note: The device supports a maximum of five point measurement objects, one line object, and three rectangular/circular objects, for a total of six analysis objects. Exceeding this limit will display an "Out number" message.

10. Vitta tool

Access "Vitta Tool" from the main menu using the "Left/right key". Six isothermal modes are available: Auto isothermal, Proportional isothermal, Down isothermal, Up isothermal, Interval isothermal, and Manual isothermal.

11. Photo view and edit

Press the "Photo view key" from the main page to enter the multimedia view. Use "Up/Down key" to select photos/videos or folders, then press "SET key" to enter. Use "Up/Down/Left/Right key" to select a picture, press "SET key" to view it, and "Left/right key" to switch between pictures.

Pressing "SET key" opens the picture interface sub-menu. Use "Left/right key" to select photo information. For UTi720E, this includes shooting time, modification time, emissivity, infrared resolution, ambient temperature, humidity, reflection distance, and QR code. For UTi730E, it includes shooting time, modification time, emissivity, infrared resolution, QR code, and remarks. You can also modify remarks, perform state editing (re-editing marking tools, image modes, etc.), manage QR codes (add, delete, classify), and delete photos.

Note: After editing, press "SET key" to open the status editing sub-menu. Use "Up key" to select "Recovery" and "SET key" to restore the picture to its initial state. Pressing "Back key" prompts "Exit or Not". Selecting "Exit" closes the page. Selecting "Save" prompts "Cover or not?". "Cover" saves changes to the original image, while "New" saves a new copy. After adding a QR code, pressing "Back key" prompts "Save and exit". Cancelling will not save the QR code. QR codes added here are not saved to the existing QR code category; modifications should be done in Settings.

12. Digital amplification & fusion ratio adjustment

Press the "Up key" on the home page to enlarge the screen. The magnification factor (1X, 2X, 4X) is displayed in the upper right corner. Use "Left/right key" to adjust the fusion degree from 0% to 100%.

13. System setup

Press "SET key" to enter the sub-menu. Use "Up/Down key" to select settings like Camera mode, Units, Parameters, Alarm, QR CODE, Language, Date and time, Wi-Fi, USB mode, Brightness, Automatic Shutdown, Factory reset, and About. Press "SET key" to enter the secondary setting page. Press "Back key" to return to the previous menu level, and again to return to the main menu.

13.1 Camera mode

In the Settings menu, select "Camera mode" and press "SET key". Use "Up/Down key" to choose between "Photo" and "Auto photo". For automatic photo taking, set the interval (10s-1000s optional).

13.2 Units

In the Settings menu, select "Units" and press "SET key". Use "Up/Down key" to select temperature or distance. For temperature, select units (°C, K, °F). Distance units cannot be changed.

13.3 Parameters

UTi720E: In the Settings menu, select "Parameter" and press "SET key". Use "Up/Down key" to select emissivity, ambient temperature, reflected temperature, relative humidity, object distance, or temperature scale. Press "SET key" to select a parameter and "Up/Down key" to change its value. For object distance, press "SET key" to enter a sub-menu for modification.

Low temperature scale: -20℃~150℃
High temperature scale: 0~550℃

Note: Switching temperature scales takes about 20 seconds. Wait for stability before proceeding.

UTi730E: In the Settings menu, select "Parameter" and press "SET key". Use "Up/Down key" to select emissivity or object distance, then press "SET key" to change. Use "Up/Down key" to select values. For object distance, press "SET key" to enter a sub-menu for modification.

Default Values: Emissivity 0.95, Ambient temperature 25°C, Reflected temperature 25°C, Relative humidity 55%RH, Object distance 0.25m.

Note: Emissivity and reflected temperature are critical. Use default values if unsure.

13.4 Alarm

In the Settings menu, select "Alarm" and press "SET key". Choose between high temperature alarm, low temperature alarm, or LED alarm using "Up/Down key". For high/low temperature alarms, set the alarm value using "Up/Down key" and "SET key".

UTi720E: -20°C-550°C (optional)
UTi730E: -40℃~400℃ (optional)

When the measured temperature exceeds the high temperature alarm value, a red positive triangle appears. When it falls below the low temperature alarm value, a green inverted triangle appears.

13.5 QR CODE

In the Settings menu, select "QR CODE" and press "SET key". Use "Up/Down key" to select QR Codes and "SET key" to enter the page for changing QR CODE name/code.

13.6 Language

In the Settings menu, select "Language" and use "Up/Down key" to choose English, French, German, Spanish, or Russian.

13.7 Date and time

In the Settings menu, select "Date and Time" and press "SET key". Use "Up/Down key" to change the time system, date, or time. For date changes, use "Left/Right key" to select year/month/day and "Up/Down key" to select the specific date.

13.8 Wi-Fi

In the Settings menu, select "Wi-Fi" and press "SET key". Press "SET key" again to open the hotspot. Use "Down key" to select the Hotspot ID and password, then set them up using "SET key".

13.9 USB mode

In the Settings menu, select "USB mode" and press "SET key". Use "Up/Down key" to choose between "USB storage" and "USB Projection", then press "SET key" to select.

13.10 Brightness

In the Settings menu, select "Brightness" and use "Up/Down key" to adjust the intensity from 1 to 100.

13.11 Automatic Shutdown

In the Settings menu, select "Automatic Shutdown" and use "Up/Down key" to choose an interval: Off, 5, 10, 20, 30, 45, 60, or 90 minutes.

13.12 Factory reset

In the Settings menu, select "Factory reset" and press "SET key". A prompt "Shutdown and factory reset" will appear. Selecting "Yes" will shut down the device, and it will restore factory settings upon the next manual startup.

13.13 Formatting

In the Settings menu, select "Formatting" and press "SET key". If an SD card is present, a "format SD card" message will appear. Selecting "Yes" formats the card. If no SD card is detected, "Unknown" will be displayed.

13.14 About

In the Settings menu, select "About" and press "SET key" to enter "Product Information". Here you can view the product model, infrared resolution, hardware version, system version, SN, SD capacity, and other related product details.

14. SD Card

The device supports microSD cards for storing images. To prevent performance issues from excessive image data, periodically back up and clear the card. To avoid data abnormalities from hot swapping, do not remove or insert the SD card repeatedly. It is recommended to do so when the device is powered off. Removing the card while viewing or operating an image will display a "SD card is lost" message.

15. Maintain

Clean the device housing with a damp cloth or mild soapy solution. Do not use grinders, isopropyl alcohol, or solvents to clean the lens or window.

16. Safety precautions

To ensure accurate measurement results, please read the instructions carefully. Use the product according to the instructions to avoid voiding the warranty. Do not use the instrument in flammable, explosive, humid, or corrosive environments. Do not use a damaged or modified instrument, as this can lead to incorrect results. Obtain actual temperature readings by referring to the radiation coefficient information; otherwise, measurements may be inaccurate.

Avoid aiming the lens at strong light sources like the sun to prevent damage to the lens or thermal imaging detector. Do not use the product in extreme hot, cold, dusty, or high-humidity environments. Refer to the product parameter table for specific temperature and humidity requirements.

The system supports USB charging. For improved efficiency, it is recommended to remove the battery pack and charge it separately.

17. FCC Compliance statement

This device complies with Part 15 of the FCC Rules. Operation is subject to two conditions: (1) the device must not cause harmful interference, and (2) it must accept any interference received, including interference that may cause undesired operation.

18. Common emissivity table

MaterialEmissivityMaterialEmissivity
Wood0.85Black paper0.86
Water0.96Poly carbonate0.8
Brick0.75Concrete0.97
Stainless steel0.14Copper oxide0.78
Adhesive tape0.96Cast iron0.81
Aluminium plate0.09Rust0.8
Copper plate0.06Gypsum0.75
Black aluminium0.95Oil paint0.9
Human skin0.98Rubber0.95
Asphalt0.96Soil0.93
PVC plastics0.93
Models: UTi730E, Thermal Imaging, UTi730E Thermal Imaging, Imaging

PDF preview unavailable. Download the PDF instead.

UTi730EUTi720E-User-Manual-English Microsoft Word 2013 Microsoft Word 2013

Related Documents

Preview UNI-T UTi720E/UTi730E Professional Thermal Imager User Manual
User manual for the UNI-T UTi720E and UTi730E Professional Thermal Imager, covering features, operation, specifications, and safety precautions.
Preview UNI-T UTi165A+ Thermal Imager User Manual - Operation and Specifications
This user manual provides comprehensive instructions for operating the UNI-T UTi165A+ Professional Thermal Imager. It covers safety precautions, device structure, display functions, menu navigation, settings, image capture and viewing, specifications, maintenance, and common emissivity values.
Preview UNI-T UTi85A Professional Thermal Imager User Manual
User manual for the UNI-T UTi85A Professional Thermal Imager, detailing its features, operation, safety guidelines, specifications, and maintenance.
Preview UTi260B Professional Thermal Imager User Manual
This user manual provides comprehensive instructions for operating the UTi260B Professional Thermal Imager, covering specifications, features, measurement functions, settings, and safety guidelines.
Preview UNI-T UTi85A Professional Thermal Imager User Manual
User manual for the UNI-T UTi85A Professional Thermal Imager, detailing its features, operation, specifications, and maintenance.
Preview UNI-T UTi260E Professional Thermal Imager User Manual
Comprehensive user manual for the UNI-T UTi260E Professional Thermal Imager, detailing its features, specifications, operation, safety guidelines, and maintenance procedures.
Preview UNI-T UTi165K Professional Thermal Imager User Manual
Comprehensive user manual for the UNI-T UTi165K Professional Thermal Imager, detailing its features, operation, safety guidelines, specifications, and maintenance. Includes instructions on image capture, viewing, settings, and connectivity.
Preview UNI-T UTi320E Professional Thermal Imager User Manual - Features, Specifications, and Operation
This user manual provides comprehensive instructions for operating the UNI-T UTi320E Professional Thermal Imager, covering technical specifications, features, maintenance, and safety guidelines.