UNI-T UTi165A+ Professional Thermal Imager

Brand: UNI-T

Model: UTi165A+

Preface

Thank you for purchasing the new UTi165A+ thermal imager. To ensure safe and correct use, please read this manual thoroughly, paying special attention to the safety instructions. It is recommended to keep the manual in an easily accessible place for future reference.

Limited Warranty and Liability

Uni-Trend guarantees the product against defects in material and workmanship for one year from the purchase date. This warranty excludes damage from accident, negligence, misuse, modification, contamination, or improper handling. Uni-Trend is not responsible for any special, indirect, incidental, or subsequent damage or loss caused by using the device.

Safety Instructions

Device Structure

The UTi165A+ is a handheld thermal imager. Key components include:

Display

The device features a 2.8-inch TFT LCD display with a resolution of 320 (vertical) x 240 (horizontal) pixels. The display shows the thermal image, including:

The display can show thermal images, visual light images, or a fusion of both, allowing users to select different blending ratios.

Power On/Off

To turn the device on or off, press and hold the [Power button] for approximately 3 seconds. The shutdown process takes 5-6 seconds. Avoid rapid on/off cycling to prevent damage.

Menu Introduction

The device is operated via a menu system accessible using the navigation buttons ([Up button], [Down button], [Left button], [Right button]) and the [SET button] for confirmation.

5.1 Measurement

This menu allows users to configure measurement parameters:

  1. Press the [SET button] to open the main menu.
  2. Use the [Left/Right button] to select the desired option.
  3. Press the [SET button] to enter the Measurement menu.
  4. Select from options like Center Spot (for single point measurement), HiLo Spot (for maximum and minimum temperature measurement), or ROI (Region of Interest).
  5. Press the [SET button] to enable or disable the selected measurement tool.
  6. Press the [Back button] to exit.

5.2 Palette

Users can select different color palettes to visualize thermal data:

  1. Press the [SET button] to open the main menu.
  2. Use the [Left/Right button] to select the Palette option.
  3. Press the [SET button] to enter the Palette menu.
  4. Use the [Up/Down button] to choose a desired palette (e.g., Iron, Rainbow, White Hot, Red Hot, Black Hot, Lava, Rainbow HC).
  5. Press the [SET button] to apply the selected palette.
  6. Press the [Back button] to exit.

5.3 Point Temperature

This feature allows users to measure the temperature at specific points on the thermal image:

  1. Press the [SET button] to open the main menu.
  2. Use the [Left/Right button] to select the point measurement option.
  3. Press the [SET button] to enter the Point Temperature menu.
  4. Use the [Up/Down button] to select the desired point (e.g., Point 1, Point 2, Point 3).
  5. Press the [SET button] to activate the point and display its temperature on the thermal imaging page.
  6. Use the [Left/Right/Up/Down button] to move the selected point on the image.
  7. Press the [SET button] again to confirm the point's position and read its temperature.
  8. Press the [SET button] to turn off the point.
  9. Press the [Back button] to exit.

5.4 Image Mode

Select how the thermal and visual data are displayed:

  1. Press the [SET button] to open the main menu.
  2. Use the [Left/Right button] to select the Image Mode option.
  3. Press the [SET button] to enter the Image Mode menu.
  4. Choose from Thermal (infrared image only), Digital (visual light image only), or Fusion (blended image).
  5. Press the [SET button] to apply the selected mode.
  6. Press the [Back button] to exit.

When Fusion mode is selected, users can adjust the blending ratio from 0% (pure visual light) to 100% (pure infrared) using the [Left/Right button].

Settings

Access the Settings menu by pressing the [SET button] from the main menu and navigating to the Settings option.

5.5.1 Language

To set the display language:

  1. Navigate to the Language option in the Settings menu.
  2. Press the [SET button] to enter the Language submenu.
  3. Use the [Up/Down button] to select between English and Chinese (中文).
  4. Press the [SET button] to confirm.
  5. Press the [Back button] to exit.

5.5.2 Date and Time

To set the device's date and time:

  1. Select the Date and Time option in the Settings menu.
  2. Press the [SET button] to enter the submenu.
  3. Use the [Left/Right button] to select the parameter to adjust (Date or Time).
  4. Press the [SET button] to enter adjustment mode.
  5. Use the [Up/Down button] to increase or decrease the value.
  6. Press the [SET button] to save the changes and return to other parameters.
  7. Press the [Back button] to exit.

5.5.3 Temperature Unit

To set the temperature unit (°C or °F):

  1. Select the Temperature Unit option in the Settings menu.
  2. Press the [SET button] to enter the submenu.
  3. Use the [Up/Down button] to select either °C or °F.
  4. Press the [SET button] to confirm.
  5. Press the [Back button] to exit.

5.5.4 HI/LO Alert

Configure high and low temperature alerts:

  1. Select the HI/LO Alert option in the Settings menu.
  2. Press the [SET button] to enter the submenu.
  3. Use the [Up/Down button] to select the desired option (HI or LO).
  4. Adjust the temperature parameter for HI or LO alerts.
  5. Select other options to turn the alerts on or off.
  6. Press the [Back button] to exit.

5.5.5 Measurements

Adjust measurement-related settings, such as emissivity:

  1. Select the Measurements option in the Settings menu.
  2. Press the [SET button] to enter the submenu.
  3. Select Emissivity.
  4. Press the [SET button] to enter adjustment mode.
  5. Use the [Up/Down button] to increase or decrease the emissivity value.
  6. Press the [SET button] to save the current setting.
  7. Press the [Back button] to exit.

Refer to the "Common Emissivity" section for emissivity values of various materials.

5.5.6 Display Brightness

Adjust the screen brightness:

  1. Select the Display Brightness option in the Settings menu.
  2. Press the [SET button] to enter the submenu.
  3. Use the [Up/Down button] to select the desired brightness level (Low, Medium, High).
  4. Press the [SET button] to confirm.
  5. Press the [Back button] to exit.

5.5.7 Auto Power Off

Set the device to automatically power off after a period of inactivity:

  1. Select the Auto Power Off option in the Settings menu.
  2. Press the [SET button] to enter the submenu.
  3. Use the [Up/Down button] to select the desired interval (5 Minutes, 10 Minutes, 30 Minutes, or Off).
  4. Press the [SET button] to confirm.
  5. Press the [Back button] to exit.

5.5.8 USB Mode

Configure the USB connection mode:

  1. Select the USB Mode option in the Settings menu.
  2. Press the [SET button] to enter the submenu.
  3. Use the [Up/Down button] to select either USB Disk or USB Camera.
  4. Press the [SET button] to confirm.
  5. Press the [Back button] to exit.

USB Disk mode allows browsing and analyzing data on a PC. USB Camera mode enables real-time image projection on a PC.

5.5.9 Auto Save

Enable or disable automatic image saving:

  1. Select the Auto Save option in the Settings menu.
  2. Press the [SET button] to enter the submenu.
  3. Use the [Up/Down button] to select Yes or No.
  4. Press the [SET button] to confirm.
  5. Press the [Back button] to exit.

Do not remove or insert the SD card while saving images. It is recommended to save no more than 1000 pictures to maintain performance. Clean the SD card periodically.

5.5.10 System Settings

Access system-level settings:

  1. Select the System Settings option in the Settings menu.
  2. Press the [SET button] to enter the System Settings submenu.

Device Information

View details about the device:

  1. Select the Device Information option.
  2. Press the [SET button] to view model, version, capacity, and free space.
  3. Press the [Back button] to exit.

Device capacity refers to the SD card storage.

Factory Reset

Restore the device to its factory default settings:

  1. Select the Factory Reset option.
  2. Press the [SET button] to enter.
  3. Select Yes to confirm.
  4. Press the [SET button] to execute the reset.
  5. Press the [Back button] to exit.

Do not interrupt the factory reset process.

Format SD Card

Format the inserted Micro SD card:

  1. Select the Format SD Card option.
  2. Press the [SET button] to enter.
  3. Select Yes to confirm.
  4. Press the [SET button] to format the card.
  5. Press the [Back button] to exit.

Do not remove the SD card or perform other operations during formatting to avoid errors.

Operating Instructions

6.1 Image Capture

To capture an image:

  1. Pull and release the [Trigger] to capture an image.
  2. In manual save mode, pull and release the [Trigger] again to save. Alternatively, use the [Left/Right button] to discard or save, then press [SET button] to confirm or [Back button] to return.
  3. In auto save mode, the image is saved automatically.

Images can only be saved if an SD card is installed.

6.2 Image Viewing

To view saved images:

  1. Press the [Replay button] to enter the gallery.
  2. Use the [Up/Down/Left/Right button] to select an image.
  3. Press the [SET button] to view the image in full screen.
  4. In full screen mode, press the [SET button] to access options like delete or view information. Use the [Left/Right button] to switch between images.

Do not remove or insert the SD card while viewing images.

6.3 Flashlight/Warning Light

Press and hold the [Flashlight button] for 3 seconds to turn the LED flashlight on or off. The LED light will flash if a high temperature alert is active and the measured temperature exceeds the set threshold.

Do not point the flashlight directly into the eyes of people or animals.

6.4 USB Communication and Image Projection

  1. Download and install the PC software (refer to UNI-T Documents Download Operation Guide).
  2. Connect the device to the PC using the USB cable.
  3. Set the USB mode to "USB Disk" to browse and analyze images via the PC software, or "USB Camera" for real-time image projection.
  4. Consult the PC software's Help section for detailed usage instructions.

Do not unplug the USB cable during image projection. Close the PC software before unplugging the cable.

6.5 SD Card

The device supports Micro SD cards for image storage. Regularly back up data and clean the SD card to maintain performance. Avoid repeatedly inserting or removing the SD card to prevent data corruption; do so only when the device is turned off.

6.6 Charging

Use a certified 5V/1A or 5V/2A power adapter for charging. Avoid turning off the product during charging. If a restart is necessary, unplug the Type-C cable and disconnect the power supply first.

Specifications

FeatureDetailsFeatureDetails
SensorUFPAVisual light cameraYes
Temperature range-10°C~400°CVisual light resolution640 x 480 pixels
Measurement resolution0.1°CImage blending ratio0% (pure visual light image), 25%, 50%, 75%, and 100% (pure infrared image)
Accuracy0°C above target temp: +/-2°C or +/-2%; Normal temp (25°C): +/-2°C or +/-2%PC softwareYes
Optimal measuring distance1 meterReal-time image transmissionYes (via PC software)
Response time<500msData transmissionType-C USB interface
IR resolution19,200 pixels (160 × 120)Product size (L x W x H)236mm x 75.5mm x 86mm
Pixel size12μmDisplay type2.8" TFT LCD
Color paletteIron, Rainbow, White Hot, Red Hot, Black Hot, Lava, Rainbow HCDisplay resolution320 x 240 pixels
Infrared spectral band8μm~14μmBattery3.6V/5000mAh rechargeable Li-ion battery
Field of view (FOV)56° (H) × 42° (V)Auto power off5 minutes, 10 minutes, 30 minutes, off (default: 30 minutes)
Spatial resolution (IFOV)6mradBattery life≥6 hours
Thermal sensitivity (NETD)<50mKCharging time<5 hours
Frame rate<9HzCharging voltage/current5V/2A
Temperature measurement displayCenter point temperature, high temperature tracking (default)Image storageMicro SD card
Image formatBMPTransportation/Storage environment-20°C~60°C (-4°F~140°F), <85% RH (non-condensing)
Image modeThermal, Digital (visual light image), FusionOperating environment0°C~50°C (32°F~122°F), 10%~95%RH (non-condensing)
Point temperature measurementIn addition to the center point, 3 points can be added.Operating altitude<2000m
Certifications-CE (EN 61326-1:2013, EN 61326-2-2:2013, EN 61326-2-3) -RoHSStandard accessoriesUser manual, USB cable, 32GB Micro SD card

Maintenance

Clean the outer shell of the device using a damp cloth or a mild soap solution. Avoid using abrasive cleaners, isopropyl alcohol, or solvents on the shell, lens, or display window.

Common Emissivity

The emissivity setting is crucial for accurate temperature measurements. Below are emissivity values for common materials:

MaterialEmissivityMaterialEmissivity
Wood0.85Black paper0.86
Water0.96Polycarbonate0.8
Brick0.75Concrete0.97
Stainless steel0.14Copper oxide0.78
Tape0.96Cast iron0.81
Aluminum plate0.09Rust0.8
Copper plate0.06Gypsum0.75
Black aluminum0.95Paint0.9
Human skin0.98Rubber0.95
Asphalt0.96Soil0.93
PVC0.93

This manual can be downloaded from the official website of Uni-Trend (refer to UNI-T Documents Download Operation Guide).

Manufacturer Information

UNI-TREND TECHNOLOGY (CHINA) CO., LTD.
No. 6, Gong Ye Bei 1st Road,
Songshan Lake National High-Tech Industrial Development Zone,
Dongguan City, Guangdong Province, China
Made in China

Models: UTi165A, UTi165B, UTi165B Professional Thermal Imager, UTi165B, Professional Thermal Imager, Thermal Imager, Imager

File Info : application/pdf, 13 Pages, 5.77MB

PDF preview unavailable. Download the PDF instead.

uti165a manual 9159

References

Corel PDF Engine Version 14.0.0.701

Related Documents

Preview UNI-T UTi85A Professional Thermal Imager User Manual
User manual for the UNI-T UTi85A Professional Thermal Imager, detailing its features, operation, safety guidelines, specifications, and maintenance.
Preview UNI-T UTi165K Professional Thermal Imager User Manual
Comprehensive user manual for the UNI-T UTi165K Professional Thermal Imager, detailing its features, operation, safety guidelines, specifications, and maintenance. Includes instructions on image capture, viewing, settings, and connectivity.
Preview UNI-T UTi260E Professional Thermal Imager User Manual
Comprehensive user manual for the UNI-T UTi260E Professional Thermal Imager, detailing its features, specifications, operation, safety guidelines, and maintenance procedures.
Preview UNI-T UTi720E/UTi730E Professional Thermal Imager User Manual
Comprehensive user manual for the UNI-T UTi720E and UTi730E Professional Thermal Imagers, detailing features, operation, system setup, maintenance, and safety precautions.
Preview UTi260B Professional Thermal Imager User Manual
This user manual provides comprehensive instructions for operating the UTi260B Professional Thermal Imager, covering specifications, features, measurement functions, settings, and safety guidelines.
Preview UNI-T UTi85A Professional Thermal Imager User Manual
User manual for the UNI-T UTi85A Professional Thermal Imager, detailing its features, operation, specifications, and maintenance.
Preview UNI-T UTi720A Professional Thermal Imager User Manual - Operation and Specifications
Comprehensive user manual for the UNI-T UTi720A Professional Thermal Imager. Covers specifications, product structure, operation, settings, measurements, maintenance, and warnings. Learn how to use your thermal imager effectively.
Preview UNI-T UTi165K Professional Thermal Imager User Manual
Comprehensive user manual for the UNI-T UTi165K Professional Thermal Imager, detailing safety, operation, specifications, and maintenance for effective thermal imaging.