ICT LX7-A Bill Acceptor
Installation Guide
1. Introduction
The LX7-A is a bill acceptor featuring a water drainage path to offer maximum protection against water and humidity.
1-1. Overview
The LX7-A is a bill acceptor featuring a water drainage path to offer maximum protection against water and humidity.
1-2. Features
- Four-way bill insertion acceptance.
- Safe lock removable and 200 or 600 bills box capacity.
- Selective lock between plastic knob and tubular lock.
2. Specifications
General
- Acceptance Rate: 96% or greater (Note: The acceptance rate excludes notes that are dirty, wet, broken or wrinkled.)
- Interface: Pulse, V2.2, NISR, ccTalk, RS232 A0, ICT Protocol <RS232>
- Transaction Speed: Approx. 3 seconds to stack
- Bill Insertion: Four-way acceptable
Electrical
- Power Source: 12V DC, 117V AC
- Power Consumption (12V DC): Standby: 0.3A, 4W; Operation: 0.8A, 10W; Maximum: 2.5A, 30W
- Power Consumption (117V AC): Standby: 63mA, 7W; Operation: 0.12A, 13.5W; Maximum: 0.27A, 30W
Operation Environment
- Operation Temperature: -15°C to 60°C
- Storage Temperature: -30°C to 70°C
- Humidity: 30% to 85% RH (no condensation)
Mechanical
- Bill Accepted Width: 62-72mm
- Bill Capacity: Approx. 200, Approx. 600 bills
- Lock Type: Plastic Knob, Tubular lock (Customize)
- Weight: Approx. 1.25kg
- Outline Dimension: Refer to page 5 for Bezel, page 6 for Plastic knob, and page 7 for Tubular lock.
3. Packing List
- Main: Bill Acceptor
- Accessory: Harness (Refer to 5-1), LX7-A Installation Guide, LX7-A DIP Switch Setting Guide, A Pair of keys (For tubular lock only)
4. Dimension
Double Open-end Standard Bezel
Part Number: 3ZMB-FAC37000
[Diagram showing dimensions for Double Open-end Standard Bezel]
Double Open-end Metal Bezel
Part Number: 3ZMB-FAC66000
[Diagram showing dimensions for Double Open-end Metal Bezel]
Plastic Knob
[Diagram showing dimensions for Plastic Knob version]
Tubular lock
[Diagram showing dimensions for Tubular lock version]
5. Installation
Note: When LX7-A is installed in down stacker direction, please remove the rubber stopper. [Warning symbol] Installation: Indoor use only!!
5-1. Harness Application
Interface | Used Voltage | Usage | Harness | Page |
---|---|---|---|---|
Pulse | 12V DC | Power & *Data Comm. | WEL-RM036 | 9 |
Pulse | 12V DC | Extension Wire | CU-R961-1 | 10 |
Pulse | 117V AC | Power & *Data Comm. | WEL-RM035 | 10 |
Pulse | 117V AC | Extension Wire | WEL-RM012 | 11 |
ICT Protocol V2.2 | 12V DC | *Data Comm. | WEL-RV706-1 or 2-BA-RV706 | 11 |
ICT Protocol V2.2 | 12V DC | Power | WEL-RM036 | 9 |
ICT Protocol V2.2 | 12V DC | Extension Wire | CU-R961-1 | 10 |
NISR | 117V AC | Power & *Data Comm. | 2-BA-RM037 | 12 |
RS232 A0 | 12V DC | *Data Comm. | WEL-RV706-1 or 2-BA-RV706 | 11 |
RS232 A0 | 12V DC | Power | WEL-RM036 | 9 |
RS232 A0 | 12V DC | Extension Wire | CU-R961-1 | 10 |
ccTalk | 12V DC | Power & *Data Comm. | WEL-RM039 | 13 |
*Data Comm.: Data Communication
5-1-1. I/O Circuit
Pulse Interface
[Diagram illustrating the I/O circuit for Pulse Interface, showing Credit O/P and Inhibit I/P connections between Bill Acceptor and Customer Side.]
ICT Protocol<RS232> & V2.2 Interface
[Diagram illustrating the I/O circuit for ICT Protocol<RS232> & V2.2 Interface, showing TXD and RXD connections.]
ccTalk Interface
[Diagram illustrating the I/O circuit for ccTalk Interface, showing TXD and RXD connections to the Money-Control System.]
NISR Interface
[Diagram illustrating the I/O circuit for NISR Interface, showing Interrupt, OUT_DATA, OUT_SERVICE, ACCEPT_EN, and IN_SEND connections.]
5-2. DIP Switch Setting
There are two serial DIP switches on the side of the LX7-A (as 5-2 FIG.01). DIP switch settings can be varied according to different currencies used by customers. There is also a serial DIP switch on the base of the unit for inside interface settings (as 5-2 FIG.02). Please refer to the “LX7-A DIP Switch Setting Guide” in the package for more details.
[Diagram showing DIP switch locations on the LX7-A unit.]
5-3. Software Download and Upgrade
To download and upgrade the software for the LX7-A, the programmer (FP-004) is needed. Please contact ICT to purchase FP-004 and refer to the FP-004 user guide for software download and upgrade information. Please turn on the Bill Acceptor after connecting.
[Diagram showing the connection setup for software download and upgrade, including LX7-A, WEL-RF302, WEL-RF303, FP-004, and PC.]
6. Maintenance
To ensure the bill acceptor operates smoothly, clean the internal parts every two weeks to every two months.
To clean the internal parts:
- Press the buttons on the sides of the bill path and pull the unit out. [Diagram showing how to release the unit.]
- Use a soft, dry cloth or towel to clean the bill path and sensors. [Diagram showing cleaning of sensors.]
Maintenance Notice: (Any improper maintenance will invalidate the warranty.)
- Recommended: Mild, non-abrasive, soap water.
- DO NOT USE: Organic solvent, Alcohol, Volatile liquid.
7. Troubleshooting
7-1. Bezel LED Errors
[Diagram of the Bezel LED on the LX7-A unit.]
LED Flashes (Red/Green) | Status | Corrective Actions |
---|---|---|
1 | White Card Calibration | Please calibrate with ICT white calibration card. |
1 | Bill jammed. | Remove the bill box by sliding the top button and the bill path, and then remove the jammed bill. |
2 | Disable. | Inspect the right DIP switch setting. |
3 | Recognition sensor module error. | Inspect the foreign objects on sensor or bill path and clean. |
3+2 | Hook sensor error. | Inspect the foreign objects on security hook and clean. |
3+4 | Out sensor error. | Inspect the foreign objects on sensor or bill path and clean. |
4 | Anti-string sensor error or a stringing attempt has detected. | Inspect the foreign objects on sensor or bill path and clean. |
5 | Bill box has been removed. | Replace the bill box. |
6 | Stacker error or stacker full. | Empty the bill box. |
7 | Motor error. | Inspect the foreign objects on bill path and clean. |
7-2. Back LED Errors
LED Flashes (Green) | Status | Corrective Actions |
---|---|---|
1 | White Card Calibration | Please calibrate with ICT white calibration card. |
1 | Bill jammed. | Remove the bill box by sliding the top button and the bill path, and then remove the jammed bill. |
2 | Disable. | Inspect the right DIP switch setting. |
3 | Recognition sensor module error. | Inspect the foreign objects on sensor or bill path and clean. |
3+2 | Hook sensor error. | Inspect the foreign objects on security hook and clean. |
3+4 | Out sensor error. | Inspect the foreign objects on sensor or bill path and clean. |
4 | Anti-string sensor error or a stringing attempt has detected. | Inspect the foreign objects on sensor or bill path and clean. |
5 | Bill box has been removed. | Replace the bill box. |
6 | Stacker error or stacker full. | Empty the bill box. |
7 | Motor error. | Inspect the foreign objects on bill path and clean. |
[Diagram showing Tubular lock and Plastic Knob lock mechanisms and how to operate them.]
! If the error cannot be solved after corrective actions or it recurs, please contact ICT for technical support.