ICT LX7-A Bill Acceptor

Installation Guide

1. Introduction

The LX7-A is a bill acceptor featuring a water drainage path to offer maximum protection against water and humidity.

1-1. Overview

The LX7-A is a bill acceptor featuring a water drainage path to offer maximum protection against water and humidity.

1-2. Features

2. Specifications

General

Electrical

Operation Environment

Mechanical

3. Packing List

4. Dimension

Double Open-end Standard Bezel

Part Number: 3ZMB-FAC37000

[Diagram showing dimensions for Double Open-end Standard Bezel]

Double Open-end Metal Bezel

Part Number: 3ZMB-FAC66000

[Diagram showing dimensions for Double Open-end Metal Bezel]

Plastic Knob

[Diagram showing dimensions for Plastic Knob version]

Tubular lock

[Diagram showing dimensions for Tubular lock version]

5. Installation

Note: When LX7-A is installed in down stacker direction, please remove the rubber stopper. [Warning symbol] Installation: Indoor use only!!

5-1. Harness Application

Interface Used Voltage Usage Harness Page
Pulse 12V DC Power & *Data Comm. WEL-RM036 9
Pulse 12V DC Extension Wire CU-R961-1 10
Pulse 117V AC Power & *Data Comm. WEL-RM035 10
Pulse 117V AC Extension Wire WEL-RM012 11
ICT Protocol V2.2 12V DC *Data Comm. WEL-RV706-1 or 2-BA-RV706 11
ICT Protocol V2.2 12V DC Power WEL-RM036 9
ICT Protocol V2.2 12V DC Extension Wire CU-R961-1 10
NISR 117V AC Power & *Data Comm. 2-BA-RM037 12
RS232 A0 12V DC *Data Comm. WEL-RV706-1 or 2-BA-RV706 11
RS232 A0 12V DC Power WEL-RM036 9
RS232 A0 12V DC Extension Wire CU-R961-1 10
ccTalk 12V DC Power & *Data Comm. WEL-RM039 13

*Data Comm.: Data Communication

5-1-1. I/O Circuit

Pulse Interface

[Diagram illustrating the I/O circuit for Pulse Interface, showing Credit O/P and Inhibit I/P connections between Bill Acceptor and Customer Side.]

ICT Protocol<RS232> & V2.2 Interface

[Diagram illustrating the I/O circuit for ICT Protocol<RS232> & V2.2 Interface, showing TXD and RXD connections.]

ccTalk Interface

[Diagram illustrating the I/O circuit for ccTalk Interface, showing TXD and RXD connections to the Money-Control System.]

NISR Interface

[Diagram illustrating the I/O circuit for NISR Interface, showing Interrupt, OUT_DATA, OUT_SERVICE, ACCEPT_EN, and IN_SEND connections.]

5-2. DIP Switch Setting

There are two serial DIP switches on the side of the LX7-A (as 5-2 FIG.01). DIP switch settings can be varied according to different currencies used by customers. There is also a serial DIP switch on the base of the unit for inside interface settings (as 5-2 FIG.02). Please refer to the “LX7-A DIP Switch Setting Guide” in the package for more details.

[Diagram showing DIP switch locations on the LX7-A unit.]

5-3. Software Download and Upgrade

To download and upgrade the software for the LX7-A, the programmer (FP-004) is needed. Please contact ICT to purchase FP-004 and refer to the FP-004 user guide for software download and upgrade information. Please turn on the Bill Acceptor after connecting.

[Diagram showing the connection setup for software download and upgrade, including LX7-A, WEL-RF302, WEL-RF303, FP-004, and PC.]

6. Maintenance

To ensure the bill acceptor operates smoothly, clean the internal parts every two weeks to every two months.

To clean the internal parts:

  1. Press the buttons on the sides of the bill path and pull the unit out. [Diagram showing how to release the unit.]
  2. Use a soft, dry cloth or towel to clean the bill path and sensors. [Diagram showing cleaning of sensors.]

Maintenance Notice: (Any improper maintenance will invalidate the warranty.)

7. Troubleshooting

7-1. Bezel LED Errors

[Diagram of the Bezel LED on the LX7-A unit.]

LED Flashes (Red/Green) Status Corrective Actions
1 White Card Calibration Please calibrate with ICT white calibration card.
1 Bill jammed. Remove the bill box by sliding the top button and the bill path, and then remove the jammed bill.
2 Disable. Inspect the right DIP switch setting.
3 Recognition sensor module error. Inspect the foreign objects on sensor or bill path and clean.
3+2 Hook sensor error. Inspect the foreign objects on security hook and clean.
3+4 Out sensor error. Inspect the foreign objects on sensor or bill path and clean.
4 Anti-string sensor error or a stringing attempt has detected. Inspect the foreign objects on sensor or bill path and clean.
5 Bill box has been removed. Replace the bill box.
6 Stacker error or stacker full. Empty the bill box.
7 Motor error. Inspect the foreign objects on bill path and clean.

7-2. Back LED Errors

LED Flashes (Green) Status Corrective Actions
1 White Card Calibration Please calibrate with ICT white calibration card.
1 Bill jammed. Remove the bill box by sliding the top button and the bill path, and then remove the jammed bill.
2 Disable. Inspect the right DIP switch setting.
3 Recognition sensor module error. Inspect the foreign objects on sensor or bill path and clean.
3+2 Hook sensor error. Inspect the foreign objects on security hook and clean.
3+4 Out sensor error. Inspect the foreign objects on sensor or bill path and clean.
4 Anti-string sensor error or a stringing attempt has detected. Inspect the foreign objects on sensor or bill path and clean.
5 Bill box has been removed. Replace the bill box.
6 Stacker error or stacker full. Empty the bill box.
7 Motor error. Inspect the foreign objects on bill path and clean.

[Diagram showing Tubular lock and Plastic Knob lock mechanisms and how to operate them.]

! If the error cannot be solved after corrective actions or it recurs, please contact ICT for technical support.

Models: H6843F-R, H6843G-R, LX7-A, LX7-A Bill Acceptor, Bill Acceptor, Acceptor

PDF preview unavailable. Download the PDF instead.

LX7-A Installation Guide EN Corel PDF Engine Version 23.1.0.389 CorelDRAW 2021

Related Documents

Preview ICT XBA-mini Bill Acceptor Installation Guide
Comprehensive installation guide for the ICT XBA-mini Bill Acceptor, detailing setup, specifications, maintenance, and troubleshooting for optimal performance.
Preview ICT BRV Series Bill Recycler Installation Guide
Installation guide for the ICT BRV Series Bill Recycler, detailing specifications, dimensions, installation procedures, maintenance, and troubleshooting.
Preview ICT PA7/PV7 Bill Acceptor Installation Guide
This guide provides detailed instructions for the installation of the ICT PA7/PV7 Bill Acceptor, covering specifications, harness applications, DIP switch settings, maintenance, and troubleshooting.
Preview XBA-OMR5 Bill Acceptor Option Switch Settings and Configuration
Comprehensive guide to XBA-OMR5 bill acceptor settings, covering option switch configurations for Pulse, MDB, ICT104U, and ICT104V interfaces, along with currency assignment data and operational notes.
Preview XBA-PHP6 Bill Acceptor DIP Switch Settings and Configuration Guide
Comprehensive guide to XBA-PHP6 bill acceptor DIP switch settings for Pulse, MDB, ICT002U, ICT104U, and ICT104V modes. Includes detailed tables for function settings, currency assignment, and manufacturing configurations.
Preview ICT UCA Series Coin Acceptor Installation Guide
Detailed installation guide for the ICT UCA Series Coin Acceptor, covering product specifications, dimensions, wiring harness applications, I/O circuit diagrams, DIP switch settings, maintenance procedures, and troubleshooting solutions.
Preview XBA-QAR3 Bill Acceptor: Option Switch Settings and Configuration Guide
Comprehensive guide to configuring the XBA-QAR3 bill acceptor by International Currency Technologies Corporation (ICT), detailing option switch settings for Pulse, MDB, ICT104U, and ICT104V modes, along with currency assignment data and operational notes.
Preview XBA-KWD4 Bill Acceptor Option Switch Settings and Configuration
Detailed guide to the XBA-KWD4 bill acceptor's option switch settings, covering supported currencies, pulse/MDB/ICT104U/ICT104V modes, and currency assignment data. Includes switch configurations for various functions and operational modes.