XBA-QAR3 Option Switch Settings
Supported bill QAR 1, 5, 10 3bills.
XBA-QAR3 Option Switch Settings
FUNCTION | SW1 | SW2 | SW3 | SW4 | SW5 | SW6 | SW7 | SW8 |
---|---|---|---|---|---|---|---|---|
Reject QAR 1 | ON | |||||||
Accept QAR 1 | OFF | |||||||
Reject QAR 5 | ON | |||||||
Accept QAR 5 | OFF | |||||||
Reject QAR 10 | ON | |||||||
Accept QAR 10 | OFF | |||||||
Reserved | DN | |||||||
Reserved | ON | |||||||
Reserved | OFF | |||||||
Reserved | ON | |||||||
Disable Bill Reject 4 Times BA Stop By 30 Sec | OFF | |||||||
Enable Bill Reject 4 Times BA Stop By 30 Sec | ON | |||||||
Stack Banknote when Power-up | UK | |||||||
Reject Banknote when Power-up | OFF | |||||||
Reserved | DN | |||||||
Reserved | OFF |
This dip switch is located at the side of XBA.
Currency Assign Data
Interface | Bill value | ICT104U | ICT104V | Pulse | MDB |
---|---|---|---|---|---|
BV1 | QAR 1 | QAR 1 | QAR 1 | QAR 1 | QAR 1 |
BV2 | QAR 5 | QAR 5 | QAR 5 | QAR 5 | QAR 5 |
BV3 | QAR 10 | QAR 10 | QAR 10 | QAR 10 | QAR 10 |
XBA-QAR3 (Pulse/MDB/ICT104U/ICT104V)
FUNCTION | SW1 | SW2 | SW3 | SW4 | SW5 | SW6 | SW7 | SW8 |
---|---|---|---|---|---|---|---|---|
Inhibit Active HIGH | ON | |||||||
Inhibit Active LOW | OFF | |||||||
Reserved | ON | |||||||
Reserved | OFF | |||||||
Reserved | ON | |||||||
Reserved | OFF | |||||||
Reserved | ON | |||||||
Reserved | OFF | |||||||
Reserved | ON | |||||||
Reserved | OFF | |||||||
Pulse Mode | MDB Mode | ICT104V Mode | ||||||
Credit-Pulse Normal HIGH Scaling Factor (SF) = 100 Decimal Point Position (DPP) = 2 | Connect with coin changer | Connect with ICT JPSTD converter board | ON | OFF | ||||
Credit-Pulse Normal LOW Scaling Factor (SF) = 1 Decimal Point Position (DPP) = 0 | ON | OFF | ||||||
Pulse Mode | Other Mode | Pulse Mode | ||||||
1 pulse / QAR 1 & 5 | MDB Mode | OFF | OFF | |||||
2 pulses / QAR 1 & 5 | Reserved | OFF | ON | |||||
4 pulses / QAR 1 & 5 | ICT104U Mode | ON | OFF | |||||
20 pulses / QAR 1 & 5 | ICT104V Mode | ON | ON |
This dip switch is located on the CPU board, remove the CPU board cover first.
A diagram illustrates the location of the DIP Switch (labeled 1) on the CPU board, accessible after removing the cover. Another callout (labeled 2) indicates the DIP Switch located on the side of the XBA unit.
Manufacture setting
- After setting dip switch of the credit pulses, you should reset the bill acceptor again.
- Note: 1. Please reset the bill acceptor after set the dip switch.
- 2. Dip switches 1 to 5 are only used for pulse protocol.
- 3. Calibration card is needed.
- 4. Pulse Mode: When Dip 1 is OFF, One Pulse per QAR 1. When Dip 1 is ON, One Pulse per QAR 5.