XBA-OMR5 Option Switch Settings
Supported bill: OMR 0.1, 0.5, 1, 5, 10 5bills.
XBA-OMR5 Option Switch Settings
FUNCTION | SW1 | SW2 | SW3 | SW4 | SW5 | SW6 | SW7 | SW8 |
---|---|---|---|---|---|---|---|---|
Reject OMR 0.1 | ON | |||||||
Accept OMR 0.1 | OFF | |||||||
Reject OMR 0.5 | ON | |||||||
Accept OMR 0.5 | OFF | |||||||
Reject OMR 1 | ON | |||||||
Accept OMR 1 | OFF | |||||||
Reject OMR 5 | ON | |||||||
Accept OMR 5 | OFF | |||||||
Reject OMR 10 | ON | |||||||
Accept OMR 10 | OFF | |||||||
Disable Bill Reject 4 Times BA Stop By 30 Sec | ON | |||||||
Enable Bill Reject 4 Times BA Stop By 30 Sec | OFF | |||||||
Stack Banknote when Power-up | ON | |||||||
Reject Banknote when Power-up | OFF | |||||||
Reserved | ON | |||||||
Reserved | OFF |
XBA-OMR5 (Pulse/MDB/ICT104U/ICT104V) Interface Settings
FUNCTION | SW1 | SW2 | SW3 | SW4 | SW5 | SW6 | SW7 | SW8 |
---|---|---|---|---|---|---|---|---|
Inhibit Active HIGH | ON | |||||||
Inhibit Active LOW | OFF | |||||||
Reserved | ON | |||||||
Reserved | OFF | |||||||
Reserved | ON | |||||||
Reserved | OFF | |||||||
Pulse Mode | ON | |||||||
Credit-Pulse Normal HIGH | ON | |||||||
Credit-Pulse Normal LOW | OFF | |||||||
Pulse Mode | ON | |||||||
Other Mode | OFF | |||||||
1 pulse / OMR 0.1 | MDB Mode | OFF | OFF | |||||
5 pulses / OMR 0.1 | Reserved | OFF | ON | |||||
10 pulses / OMR 0.1 | ICT104U Mode | ON | OFF | |||||
25 pulses / OMR 0.1 | ICT104V Mode | ON | ON |
ICT104V Mode Specific Settings:
- Connect with coin changer: SW7 is ON
- Connect with ICT JPSTD converter board: SW8 is ON
Dip Switch Location
This dip switch is located at the side of XBA.
Illustration showing the side of the XBA bill acceptor. A circular callout highlights a bank of DIP switches, labeled (2).
This dip switch is located on the CPU board, remove the CPU board cover first.
Illustration showing the internal components of the bill acceptor. An arrow indicates removing the CPU board cover. A close-up view of the CPU board shows a DIP switch labeled (1).
Currency Assign Data
Bill value | Interface ICT104U | MDB | ICT104V | Pulse |
---|---|---|---|---|
BV1 | OMR 0.1 | OMR 0.1 | OMR 0.1 | OMR 0.1 |
BV2 | OMR 0.5 | OMR 0.5 | OMR 0.5 | OMR 0.5 |
BV3 | OMR 1 | OMR 1 | OMR 1 | OMR 1 |
BV4 | OMR 5 | OMR 5 | OMR 5 | OMR 5 |
BV5 | OMR 10 | OMR 10 | OMR 10 | OMR 10 |
Manufacturing Settings and Notes
* Manufacture setting
After setting dip switch of the credit pulses, you should reset the bill acceptor again.
Note:
- Please reset the bill acceptor after set the dip switch.
- Dip switches 1 to 5 are only used for pulse protocol.