Positioning
For the earliest warning, smoke alarms should be fitted in all rooms where the temperature is between 4°C (40°F) and 38°C (100°F).
WARNING: Prolonged exposure to temperatures outside these limits will reduce product life.
Smoke alarms should be sited at least 300mm from light fittings and walls. Ideally, position them as centrally as possible in the room.
Smoke alarms should be positioned no more than 600mm vertically below the highest point in the room.
When mounting on a wall, the top of the detection element must be between 150mm and 300mm below the ceiling, and at least 300mm from a wall.
Thermoptek smoke alarms are less prone to false alarms from cooking fumes, making them suitable for locations near kitchens. However, like other smoke alarms, they can be subject to nuisance alarms from steam and should not be placed near bathrooms.
IMPORTANT: Check local building and fire regulations for your property to ensure compliance.
Mobile Homes & Caravans
This smoke alarm is suitable for use in mobile homes and caravans.
Commercial & Industrial Premises
This smoke alarm is not intended for non-residential, commercial, or industrial applications, nor for any other purpose than described above.
Alarm Features
Alarm Smart Silence
Smoke alarms can react to cooking fumes or other non-emergency situations. Your alarm features 'Smart Silence' technology. In the event of a known false alarm, you can temporarily silence it by pressing the Test button. The alarm will automatically return to full sensitivity after 10 minutes.
NOTE: If the smoke level reaching the alarm is very high, the alarm silence will be overridden, and the alarm will continue to sound.
DANGER: Never ignore any alarm. If an alarm is sounding, it is warning you of a potentially hazardous situation. Do not ignore it. Ignoring the alarm may result in injury or death. If your smoke alarm activates and you are not absolutely certain of the source of smoke, get everyone out of the house immediately.
Operational Modes
Sleep Easy
Your smoke alarm will still detect smoke during the Sleep Easy mode, but you must replace the batteries within 30 days.
Low Battery
You can silence the low battery warning chirp for a maximum of 10 times. Replace the batteries in your smoke alarm immediately to ensure protection in case of fire. If the red LED flashes at a separate time from the chirp, a fault is indicated. Contact Technical Support if the unit is within warranty; otherwise, replace the alarm immediately.
WARNING: Your smoke alarm cannot be silenced if the chirp indicates a fault.
IMPORTANT: Use of a battery other than those recommended below may have a detrimental effect on the alarm. Recommended alkaline type: Energizer E91 / Duracell MN1500bB / Panasonic ProPower LR6.
Technology
Thermoptek Sensor Technology
Thermoptek technology provides a fast reaction to both slow smouldering and fast flaming fires in a single alarm. It constantly monitors temperature changes; if a rate of temperature rise is detected, the sensitivity of the alarm is increased.
Maintenance and Disposal
Maintenance
CAUTION: Do not paint the smoke alarm.
Disposal
In accordance with the WEEE Directive 2012/19/EU, waste electrical products should not be disposed of with regular household waste. The batteries should be removed before disposal of the detector, and both should be disposed of in line with local regulations.
WARNING: Do not open the alarm. Do not burn.
Warranty Information
Who is covered?
This warranty covers the original purchaser of the ST-625-INT product only.
How long does the warranty last?
This warranty remains in force for 2 years from the date of purchase.
What does this warranty cover?
This warranty covers defects in material or workmanship.
What does this warranty not cover?
This warranty does not cover damage resulting from accidents, misuse, disassembly, abuse, or lack of reasonable care of the product. It also does not cover events or conditions outside of Sprue's control, such as Acts of God (fire, severe weather, etc.). This warranty does not cover batteries, which are considered user-replaceable parts.
Customer Support
For returns, please deliver the product, along with proof of purchase, to Sprue Safety Products, Vanguard Centre, Sir William Lyons Road, Coventry, CV4 7EZ.
Full warranty details can be found online at: www.fireangel.eu
Compliance
The device carries CE marking.
It complies with EN 14604:2005 +AC:2008 for smoke alarm devices.
DOP: SADOPST-625-02