Lennox EL18KSLV Elite Series Heat Pump Outdoor Units
Product Type: Heat Pump Outdoor Unit
Series: Elite® Series
Key Features: Cold Climate | Variable Capacity | Side Discharge | R-454B Refrigerant | 60Hz
Efficiency Ratings: SEER2 up to 19.0, HSPF2 up to 10.0
Capacity Range: 2 to 5 Tons
Cooling Capacity: 22,200 to 55,500 Btuh
Heating Capacity: 23,600 to 56,000 Btuh
Model Number Identification
The model number provides key information about the unit's configuration:
- Product Tier: EL = Elite® Series
- Nominal SEER2: 18 = 18.0 to 18.9 SEER
- Refrigerant Type: K = R-454B
- Configuration: S = Side Discharge
- Unit Type: L = Cold Climate Heat Pump
- Cooling Stages: V = Variable Capacity Compressor
- Voltage: 230 = 208/230V-1 phase-60Hz
- Ratings Revision Level: Specifies revision of ratings.
- Nominal Cooling Capacity: 024 = 2 tons, 036 = 3 tons, 060 = 4/5 tons
Example Model Number: EL18KSLV-036-230 A 01
Approvals and Warranty
- AHRI Certified to AHRI Standard 210/240-2023
- ENERGY STAR® Cold Climate certified
- Sound rated to AHRI Standard 270-2008
- Rated according to U.S. Department of Energy (DOE) test procedures
- UL, NEC, and CEC compliant for grounding
- ETL certified (U.S. and Canada)
- ISO 9001 Registered Manufacturing Quality System
Warranty
- Compressor: 10 years (residential), 5 years (non-residential)
- All other components: 5 years (residential), 1 year (non-residential)
Refer to Lennox® Basic Limited Warranty at www.Lennox.com for additional details.
Features
Applications
- Available in 2 through 5 ton sizes.
- Sound levels as low as 54 dBA.
- Single phase power supply (208/230V).
- Side discharge air flow.
- Units are shipped completely factory assembled, internally piped, and wired.
- The EL18KSLV-060 model can be configured for 4 or 5 ton operation.
- Can be used in dual-fuel systems with compatible thermostats (sold separately).
Refrigeration System
- Refrigerant: R-454B (Low GWP, Zero ODP, Low Toxicity/Lower Flammability - A2L)
- Outdoor Coil: Aluminum fins bonded to copper tubes.
- Outdoor Fan: Direct drive fan for uniform airflow and high refrigeration capacity. Fan guard provided.
- Refrigerant Line Connections: Flare connections on unit cabinet. Fully serviceable brass service valves. Suction and liquid extension pipes furnished.
Indoor Refrigerant Detection System (RDS)
- Complies with UL 60335-2-40 standard.
- Required for all systems using R-454B refrigerant.
- Detects R-454B refrigerant, stops compressor, and operates blower to reduce concentrations for safe operation.
Compressor
- Variable Frequency Rotary Compressor: High efficiency, balanced for reduced vibration and quiet operation. Uses powerful Neodymium magnets.
- Compressor Crankcase Heater: Protects against liquid refrigerant migration during low ambient operation.
Controls
- DC Inverter Control: Adjusts capacity based on room temperature for efficient operation.
- Inverter Module Protection: Protects against electrical differences and indicates servicing needs.
- Outdoor Unit Microprocessor: Controls electronic expansion valve, compressor timed-off protection, temperature sensors, and reversing valve. Displays error codes via LEDs.
- Electronic Expansion Valve: Controls refrigerant flow for heating.
- Compressor Overcurrent Protection: Protects against high ambient temperature, locked rotor, or blocked airflow.
- Condenser High Temperature Protection: Monitors outdoor coil temperature and adjusts compressor operation to prevent overheating.
- Compressor Discharge Temperature Protection: Monitors compressor discharge line temperature and adjusts operation to prevent overheating.
- Voltage Protection: Protects against low or high voltage fluctuations.
- Terminal Strip: Facilitates easy wiring connections.
- Defrost Control: Automatically initiates defrost cycle when frost builds up on the outdoor coil. Outdoor fan is off during defrost. An indicator LED on the indoor unit panel illuminates.
- Reversing Valve: 4-way valve for quick changeover between heating and cooling modes.
Optional Accessories
E30 Smart Wi-Fi Thermostat
- Wi-Fi enabled, electronic, 7-day programmable, multi-stage, touchscreen thermostat.
- Features: 3 Heat/2 Cool, Auto-changeover, controls dehumidification/humidification, dewpoint measurement, Humiditrol® control, equipment maintenance reminders.
- 7-inch color touchscreen display shows current/set temperature, humidity, system status, and outdoor temperature (with optional sensor).
- Includes: Smooth Setback Recovery, compressor short-cycle protection (5 minutes), up to four schedules, One-Touch Away Mode, Smart Away™ (geo-fencing), Wi-Fi remote monitoring, compatibility with Apple HomeKit™, Amazon Alexa®, Google Assistant, and IFTTT.
- Service Dashboard for online monitoring of installed thermostats.
- High Definition Color Display with Subbase, Smart Hub Controller, and wallplate.
Remote Outdoor Temperature Sensor
- Used with the E30 Smart Wi-Fi Thermostat to display outdoor temperature.
- Sensor is auto-detected when connected.
Note: Thermostat is not furnished with the unit. See Lennox Price Book or LennoxPros for selection.
Cabinet
- Constructed of heavy gauge steel.
- Tabs on unit base for secure mounting to slab.
- Condensate drain outlets furnished on unit base (drain must be field furnished).
- Pan heater prevents ice build-up during heating operation.
- Access covers for power/control wiring and service valves.
- Includes four rubber dampening pads.
Specifications
Size | Nominal Size - Tons | Ambient Temperature Range - °F (Cooling) | Ambient Temperature Range - °F (Heating) | Sound Data (low) dBA | Refrigerant | Max Line Length (ft) | Add'l Charge per ft. (oz) | Compressor Type | Refrigerant Oil Type | Refrigerant Oil Charge (oz) |
---|---|---|---|---|---|---|---|---|---|---|
024 | 2 | 5°F - 115°F | -22°F - 86°F | 54 | R-454B (3 lbs. 9 oz.) | 15 | 0.55 | (1) Variable Rotary | HAF68D1C | 30.4 |
036 | 3 | 5°F - 115°F | -22°F - 86°F | 57 | R-454B (5 lbs. 9 oz.) | 15 | 0.55 | (1) Variable Rotary | RM68EH | 29.4 |
048 | 4 | 5°F - 115°F | -22°F - 86°F | 62 | R-454B (7 lbs. 8 oz.) | 15 | 0.55 | (1) Variable Rotary | RM68EH | 47.3 |
060 | 4/5 | 5°F - 115°F | -22°F - 86°F | 62 | R-454B (7 lbs. 8 oz.) | 15 | 0.55 | (1) Variable Rotary | RM68EH | 47.3 |
Size | Connections (Liquid OD) | Connections (Suction OD) | Refrigerant Line Size - Liquid (in.) | Refrigerant Line Size - Suction (in.) | Max Line Length (ft) | Max Height Difference (ft) | Outdoor Coil Net Face Area (sq ft) | Tube Diameter (mm) | Rows | Fins | Fin Type | Tube Type |
---|---|---|---|---|---|---|---|---|---|---|---|---|
024 | 3/8 | 5/8 | 3/8 | 3/4 | 150 | 50 | 7.19 | 7 | 3 | 18 | Hydrophilic aluminum | Inner Grooved Copper Tube |
036 | 3/8 | 3/4 | 3/8 | 3/4 - same as unit connection | 150 | 50 | 9.61 | 7 | 3 | 18 | Hydrophilic aluminum | Inner Grooved Copper Tube |
048 | 3/8 | 3/4 | 3/8 | 7/8 | 100 | 50 | 16.7 | 7 | 2 | 18 | Hydrophilic aluminum | Inner Grooved Copper Tube |
060 | 3/8 | 3/4 | 3/8 | 7/8 | 100 | 50 | 16.7 | 7 | 2 | 18 | Hydrophilic aluminum | Inner Grooved Copper Tube |
Size | Outdoor Fan HP | Outdoor Fan (Number) Diameter (in.) | Blades | Total Air Volume (cfm) | Rpm | Watts | Shipping/Net Data (lbs.) |
---|---|---|---|---|---|---|---|
024 | 1/4 | (1) 22 | 3 | 3000 | 680 | 160 | 137/161 |
036 | 1/4 | (1) 25 | 3 | 3330 | 700 | 200 | 157/190 |
060 | (2) 1/4 | (2) 24 | 3 | 5970 | 750 | (2) 160 | 245/280 |
ELECTRICAL DATA | Line voltage data (Volts-Phase-Hz) | Maximum Overcurrent Protection (MOCP) amps | Minimum circuit ampacity (MCA) | Compressor Rated Load Amps | Fan Motor Rated load amps |
---|---|---|---|---|---|
208/230-1-60 | 30 | 21 | 14.5 | 1.2 | |
208/230-1-60 | 35 | 24 | 16.5 | 1.5 | |
208/230-1-60 | 60 | 37 | 26.4 | 2.4 |
Note: Extremes of operating range are plus and minus 10% of line voltage. Refrigerant charge is sufficient for 15 ft. of refrigerant lines. For longer line set requirements, refer to Installation Instructions for additional refrigerant charge.
Dimensions
EL18KSLV-024 (2 Ton)
Front View: Width: 40-1/4 in. (1022 mm), Height: 36-3/8 in. (924 mm)
Side View: Width: 15-3/4 in. (400 mm), Height: 30 in. (762 mm)
Bottom View: Width: 26 in. (660 mm), Height: 15-13/16 in. (401 mm)
EL18KSLV-036 (3 Ton)
Front View: Width: 43-1/8 in. (1095 mm), Height: 41-1/2 in. (1054 mm)
Side View: Width: 17 in. (432 mm), Height: 33-1/8 in. (841 mm)
Bottom View: Width: 29-1/2 in. (749 mm), Height: 18-1/8 in. (460 mm)
EL18KSLV-060 (4/5 Ton)
Front View: Width: 41-5/8 in. (2057 mm), Height: 56-3/8 in. (1432 mm)
Side View: Width: 17 in. (432 mm), Height: 56-3/8 in. (1432 mm)
Bottom View: Width: 29-1/2 in. (749 mm), Height: 18-1/8 in. (460 mm)
Installation Clearances
Proper clearances are essential for optimal performance and serviceability. Refer to the diagrams for specific requirements.
Single Unit Installation Clearances
- Back: Minimum 4 in. (102 mm)
- Front: Minimum 14 in. (356 mm)
- Back and Side: Minimum 6 in. (152 mm) on back, Minimum 12 in. (305 mm) on side.
- Front and Back: Minimum 6 in. (152 mm) on back, Minimum 20 in. (508 mm) on front.
- Top (With Barriers): Minimum 6 in. (152 mm) clearance required if barriers are present.
- Back and Side (With Barriers): Minimum 40 in. (1016 mm) clearance required if barriers are present.
Note: Top and two sides of the unit must be exposed to open space. Any barriers on one side of the front or back must be lower than unit height.
Minimum Clearances Summary
- Control Box (Service): 30 in. (762 mm)
- Discharge Air: 14 in. (356 mm)
- Space Between Units: 4 in. (102 mm)
- Space From Wall: 4 in. (102 mm)
Note: Maximum soffit overhang is 36 inches (914 mm). At least one side should be unobstructed by a wall or other barrier.
TXV Substitution - R-454B
This table provides a guide for replacing the factory-installed R-454B TXV if the indoor unit (coil/air handler) is larger or smaller than the outdoor unit.
Outdoor Unit Size | Tons | Indoor Unit Size | Tons | Indoor TXV Furnished | Indoor TXV Replacement |
---|---|---|---|---|---|
024 | 2 | 42 | 3.5 | 26Z71 | 26Z70 |
024 | 2 | 48 | 4 | 26Z71 | 26Z70 |
024 | 2 | 49 | 4 | 26Z71 | 26Z70 |
024 | 2 | 50/60 | 4/5 | 26Z71 | 26Z70 |
024 | 2 | 51/61 | 4/5 | 26Z71 | 26Z70 |
024 | 2 | 60 | 5 | 26Z72 | 26Z70 |
036 | 3 | 42 | 3.5 | 26Z71 | 26Z70 |
036 | 3 | 48 | 4 | 26Z71 | 26Z70 |
036 | 3 | 49 | 4 | 26Z71 | 26Z70 |
036 | 3 | 50/60 | 4/5 | 26Z71 | 26Z70 |
036 | 3 | 51/61 | 4/5 | 26Z71 | 26Z70 |
036 | 3 | 60 | 5 | 26Z72 | 26Z70 |
048 | 4 | 30/36 | 2.5/3 | 26Z70 | 26Z71 |
048 | 4 | 36 | 3 | 26Z70 | 26Z71 |
048 | 4 | 60 | 5 | 26Z72 | 26Z71 |
060 | 5 | 50/60 | 4/5 | 26Z71 | 26Z72 |
060 | 5 | 51/61 | 4/5 | 26Z71 | 26Z72 |
TXV Ranges:
- 26Z70: 1.5 to 3 ton systems - Use on 3 ton (036) and lower systems.
- 26Z71: 3.5-4 ton systems - Use on 4 ton (048) and down to 3.5 ton (042) systems.
- 26Z72: 5 ton systems - Use on 5 ton (060) systems only.
AHRI Standard 210/240-2023
Standard ratings for cooling or heating capacities are net values, including the effects of circulating-fan heat, but not including supplementary electric heat. Power input used for calculating efficiency is the Total Power.
For units without indoor air-circulating fans, ratings are adjusted by subtracting 1,505 Btu/h per 1,000 SCFM for cooling and adding the same amount for heating (for non-mobile-home, non-Space Constrained units). Total Power for both heating and cooling is increased by 441 W per 1,000 SCFM of indoor air circulated.
Certifications and Contact Information
- AHRI Certified
- HRAI Member Company
- ETL Listed (Intertek)
Visit Lennox: www.Lennox.com
For Technical Information: www.LennoxPros.com
Contact: 1-800-9-LENNOX
Note: Specifications, ratings, and dimensions are subject to change without notice. Improper installation, adjustment, alteration, service, or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency.
©2024 Lennox Industries, Inc.