Lennox EL22XPV Elite Series Heat Pump Outdoor Units
Variable Capacity - Precise Comfort® Technology - R-410A - 60 Hz
Bulletin No. 210988
February 2023
RESIDENTIAL PRODUCT SPECIFICATIONS
Model: EL22XPV
Series: ELITE®
Key Features:
- SEER2 up to 22.0 / SEER up to 23.0
- HSPF2 up to 9.0 / HSPF up to 10.35
- Cooling Capacity: 22,800 to 55,500 Btuh (2 to 5 Tons)
- Heating Capacity: 22,200 to 58,000 Btuh
Thermostat Compatibility:
- S40 Smart Wi-Fi Communicating Thermostat (ordered separately)
- Compatible with conventional thermostats
Refrigerant: R-410A
MODEL NUMBER IDENTIFICATION
Example: EL 22 X PV - 036 - 230 A 01
- Product Tier: EL = Elite® Series
- Nominal Efficiency: (Not specified in model number)
- Refrigerant Type: X = R-410A
- Unit Type: P = Heat Pump Outdoor Unit
- Cooling/Heating Stages: V = Variable Capacity Compressor
- Nominal Cooling Capacity: 024 = 2 tons, 036 = 3 tons, 048 = 4 tons, 060 = 5 tons
- Voltage: 230 = 208/230V - 1 phase - 60Hz
- Revision Level: (Specified in model number)
- Ratings Revision Level: (Specified in model number)
FEATURE HIGHLIGHTS
- Outdoor Coil Fan: Direct drive, ECM motor, totally enclosed, ball bearings, inherently protected.
- Quantum™ Coil: Lennox designed and fabricated, enhanced aluminum alloy tube/enhanced fin coil, superior corrosion resistance, ripple-edged aluminum fins, aluminum tube construction, lanced fins for maximum fin surface exposure, fin collars grip tubing, flared shoulder tubing connections, factory tested under high pressure, accessible for cleaning.
- High Capacity Liquid Line Drier: Factory installed, traps moisture or dirt, 100% molecular-sieve, bead type, bi-flow drier.
- High Pressure Switch: Protects system from high pressure conditions, automatic reset.
- Four-Way Reversing Valve: Rapid changeover of refrigerant flow direction, operates on pressure differential.
- Variable Speed Compressor: Rotary compressor (024 and 036 models), Scroll compressor (048 and 060 models), high volumetric efficiency, uniform suction flow, constant discharge flow, quiet operation, low gas pulses, internally protected, resilient rubber mounts.
- DC Inverter Control: Converts AC to DC voltage, provides continuous compressor operation, adjusts capacity in 1% increments, Power Factor Correction (PFC) circuit, two LEDs for status, noise filter reduces EMI.
- Lennox® Communicating Control: Advanced control, communicates with Lennox® Communicating Thermostats, auto configuration, seven-segment display for alerts, low voltage protection, high/low pressure switch monitoring, five-strike lockout protection, liquid line temperature monitoring, EEPROM storage, built-in low-ambient control.
- Heavy Gauge Steel Cabinet: Pre-painted finish, louvered panels, convenient control box, corner patch plate for access, drainage holes, high-density polyethylene unit support feet, PermaGuard™ Unit Base for rust and corrosion resistance.
- SmartHinge™ Louvered Coil Protection: Steel louvered panels, hinged for easy cleaning and servicing, interlocking tabs and slots.
- Refrigerant Line Connections and Access: Sweat connection vapor and liquid lines, located on corner of unit cabinet, vapor valve can be fully shut off, liquid valve can be front seated, refrigerant line connections and field wiring inlets in one central area.
REFRIGERATION SYSTEM
- Refrigerant: R-410A, non-chlorine, ozone friendly.
- Unit Charge: Factory pre-charged. Total system charge depends on outdoor unit size, indoor unit size, and refrigerant line length. Refer to unit-mounted charging sticker.
- Discharge Temperature Switch: Shuts off unit if discharge line temperature rises above setpoint, protects compressor, automatic reset.
- Low Pressure Transducer: Shuts off unit if suction pressure falls below setting, provides loss of charge and freeze-up protection, automatic reset.
- Expansion Valve: Outdoor unit, designed and sized for heat pump system, senses suction temperature.
PRECISE COMFORT® TECHNOLOGY
The Variable Capacity Rotary Compressor and DC Inverter Control work together to reduce energy usage compared to conventional heat pumps.
- Compressor Crankcase Heater: Factory installed, protects against refrigerant migration during low ambient operation.
- Compressor Sound Dampening System: Polyethylene compressor, 2 inch thick fiberglass insulation, sealed edges.
CONTROLS
- Lennox® Communicating Control: Advanced control system for optimal comfort, performance, and efficiency. Connects to Lennox® Communicating Thermostats. Auto configuration, seven-segment display, low voltage protection, pressure switch monitoring, lockout protection, liquid line temperature monitoring, EEPROM storage, alarm code storage, built-in low-ambient control.
- Low Ambient Operation: Cooling mode down to 0°F outdoor air. Heating mode operates down to -4°F, continues until thermostat is satisfied or drops to -15°F.
- Climate IQ™ Technology: Optimizes dehumidification settings for improved home comfort. Monitors regional weather conditions.
- Lennox® Communicating Thermostat Settings: Includes Dry, Moderate, and Humid modes for cooling, and Normal and Comfort modes for heating. Climate IQ (Auto) adjusts modes based on humidity.
- Outdoor Air Temperature Sensor: Used with Lennox® Communicating Thermostats to display outdoor temperature.
OPTIONAL ACCESSORIES
- Expansion Valve Kits
- Freezestat
- Refrigerant Line Kits
- Snow Guards (available in Canada for 048, 060 models)
- Compressor Low Ambient Cut-Off Switch
- Indoor Blower Off Delay Relay
SPECIFICATIONS
General Data | Model No. | EL22XPV-024 | EL22XPV-036 | EL22XPV-048 | EL22XPV-060 | |
---|---|---|---|---|---|---|
Nominal Tonnage | 2 | 3 | 4 | 5 | ||
Connections (sweat) | Liquid line (o.d.) - in. | 3/8 | 3/8 | 3/8 | 3/8 | |
Vapor line (o.d.) - in. | 3/4 | 7/8 | 7/8 | 1-1/8 | ||
Refrigerant | R-410A charge furnished | 12 lbs. 5 oz. | 12 lbs. 7 oz. | 13 lbs. 7 oz. | 13 lbs. 2 oz. | |
Outdoor Coil | Net face area - sq. ft. | Outer coil | 21.00 | 21.00 | 27.22 | 27.22 |
Inner coil | 20.27 | 20.27 | 26.36 | 26.36 | ||
Tube diameter - in. | 5/16 | 5/16 | 5/16 | 5/16 | ||
No. of rows | 2 | 2 | 2 | 2 | ||
Fins per inch | 22 | 22 | 22 | 22 | ||
Outdoor Fan | Diameter - in. | 26 | 26 | 26 | 26 | |
No. of blades | 3 | 3 | 3 | 3 | ||
Motor hp | 1/3 | 1/3 | 1/3 | 1/3 | ||
Cfm | 2580 | 3650 | 3860 | 4550 | ||
Rpm | 720 | 765 | 805 | 970 | ||
Watts | 69 | 155 | 169 | 263 | ||
Shipping Data - lbs. 1 package | 250 | 250 | 358 | 360 | ||
ELECTRICAL DATA | Line voltage data - 60 Hz | 208/230V-1ph | 208/230V-1ph | 208/230V-1ph | 208/230V-1ph | |
Maximum Overcurrent Protection (MOCP) amps | 20 | 30 | 40 | 50 | ||
Minimum Circuit Ampacity (MCA) | 13.4 | 19.9 | 24.6 | 33.5 | ||
Compressor | Input amps | 8.6 | 13.9 | 17.6 | 24.7 | |
Outdoor Fan Motor | Full load amps | 2.6 | 2.6 | 2.6 | 2.6 | |
CONTROLS | S40 Smart Wi-Fi Thermostat | 22V24 | • | • | • | • |
E30 Smart Wi-Fi Thermostat | 20A65 | • | • | • | • | |
Discharge Air Temperature Sensor | 88K38 | • | • | • | • |
OPTIONAL ACCESSORIES - ORDER SEPARATELY
Accessory | Model No. | EL22XPV-024 | EL22XPV-036 | EL22XPV-048 | EL22XPV-060 | |
---|---|---|---|---|---|---|
Freezestat | 3/8 in. tubing | 93G35 | • | • | • | • |
Indoor Blower Off Delay Relay | 58M81 | • | • | • | • | |
Refrigerant Line Sets (Liq. x Suc. OD x Insulation Thickness - Length) | 3/8 x 3/4 x 3/8 - 20 ft. | 89J56 | • | |||
3/8 x 3/4 x 3/8 - 30 ft. | 89J57 | • | • | |||
3/8 x 3/4 x 3/8 - 40 ft. | 89J58 | • | ||||
3/8 x 3/4 x 3/8 - 50 ft. | 89J59 | • | • | |||
3/8 x 7/8 x 3/8 - 30 ft. | 89J60 | • | ||||
3/8 x 7/8 x 3/8 - 40 ft. | 89J61 | • | • | |||
3/8 x 7/8 x 3/8 - 50 ft. | 89J62 | • | ||||
3/8 x 1-1/8 x 3/8 - 30 ft. | X0570 | • | ||||
3/8 x 1-1/8 x 3/8 - 50 ft. | 73P91 | • | ||||
Snow Guard | 28-1/2 x 27-1/2 in. | X8781 | • | |||
35-1/2 x 31 in. (Canada Only) | X8780 | • | • | • |
NOTE: Refrigerant charge is sufficient for 15 ft. of refrigerant lines. For longer line sets, refer to installation instructions.
SOUND DATA
Octave Band Sound Power Levels dBA, re 10⁻¹² Watts
Unit Model | 125 | 250 | 500 | 1000 | 2000 | 4000 | 8000 | Sound Rating Number (dBA) | Estimated Sound Pressure Level at Distance From Unit (dBA at distance in ft.) | ||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 5 | 10 | 15 | 50 | |||||||||
024 Min. | 51 | 54.5 | 56.5 | 54 | 50 | 49 | 52 | 62 | 55 | 50 | 44 | 41 | 30 |
024 Max. | 54 | 63.5 | 63 | 65 | 61.5 | 61 | 56.5 | 70 | 63 | 58 | 52 | 49 | 38 |
036 Min. | 51.5 | 52.5 | 54 | 55.5 | 50.5 | 48.5 | 51.5 | 61 | 54 | 49 | 43 | 40 | 29 |
036 Max. | 55 | 62.5 | 67.5 | 67.5 | 65.5 | 65 | 59.5 | 73 | 66 | 61 | 55 | 52 | 41 |
048 Min. | 53 | 56 | 60.5 | 57.5 | 54 | 47 | 39 | 69 | 62 | 57 | 51 | 48 | 37 |
048 Max. | 54.5 | 60 | 65.5 | 66 | 62 | 62 | 62 | 71 | 66 | 61 | 55 | 52 | 41 |
060 Min. | 52 | 54.5 | 58.5 | 55.5 | 52 | 48.5 | 50 | 63 | 56 | 51 | 45 | 42 | 31 |
060 Max. | 58 | 69.5 | 70.5 | 70.5 | 67 | 61.5 | 55.5 | 76 | 61 | 57 | 51 | 48 | 37 |
NOTE: Sound rating number is the overall A-Weighted Sound Power Level (LWA).
FIELD WIRING
Wiring configurations vary based on the thermostat type:
- A - Two Wire Power
- B - Two or Three Wire Power (size to heater capacity)
- C - Lennox® Communicating Thermostat: Four Wire, 18AWG (RSBus)
- C - Conventional Thermostat: Eight Wire Low Voltage, 18AWG or Ten Wire Low Voltage, 18AWG with Optional Outdoor Thermostat
- D - Lennox® Communicating Thermostat: Four Wire, 18 to 22AWG (RSGBus) standard thermostat cable.
- D - Conventional Thermostat: Twelve Wire Low Voltage, 18AWG or Fourteen Wire Low Voltage, 18AWG with Optional Outdoor Thermostat
NOTE: All wiring must conform to NEC or CEC and local electrical codes. Field wiring is not furnished.
INSTALLATION CLEARANCES
Specific clearances are required for proper operation and servicing:
- Service clearance of 30 in. (762 mm) on the side adjacent to the control box.
- Clearance to one of the other three sides must be 36 in. (914 mm).
- Clearance to one of the remaining two sides may be 12 in. (305 mm).
- The final side may be 6 in. (152 mm).
- A clearance of 24 in. (610 mm) between two units.
- 48 in. (1219 mm) clearance required on top of the unit.
DIMENSIONS - UNIT
Top View: Shows suction and liquid line connections.
Side View: Shows discharge air, liquid line connection, electrical inlets, and suction line connection.
End View: Shows overall dimensions.
Base Section (Large Base): Dimensions provided for the base.
Model No. | A (Height) in. | A (Height) mm |
---|---|---|
EL22XPV-024 | 39 | 991 |
EL22XPV-036 | 39 | 991 |
EL22XPV-048 | 45 | 1143 |
EL22XPV-060 | 45 | 1143 |
TXV USAGE
Table for C35, CH23 and CR33 Field Installed TXV Match-Ups.
Model No. | Order No. |
---|---|
EL22XPV-024 | 12J18 |
EL22XPV-036 | 12J19 |
EL22XPV-048 | 12J20 |
EL22XPV-060 | 12J20 |
NOTE: CX35 and CHX35 coils and Lennox air handlers are shipped with a factory installed TXV. If a change out is required, refer to the TXV SUBSTITUTION table. The correct TXV must be ordered separately and field installed.
TXV SUBSTITUTION
Guide for replacing the factory installed TXV if the indoor unit is larger or smaller than the outdoor unit.
Outdoor Unit Size Tons | Indoor Unit Size | Indoor Unit Tons | TXV Furnished | TXV Replacement |
---|---|---|---|---|
024 2 | 42 | 3.5 | 12J20 | 12J18 |
024 2 | 48 | 4 | 12J20 | 12J18 |
024 2 | 49 | 4 | 12J20 | 12J18 |
024 2 | 50/60 | 5 | 12J20 | 12J18 |
024 2 | 51/61 | 5 | 12J20 | 12J18 |
024 2 | 60 | 5 | 12J20 | 12J18 |
036 3 | 24 | 2 | 12J18 | 12J19 |
036 3 | 30 | 2.5 | 12J18 | 12J19 |
048 4 | 30/36 | 2.5/3 | 12J19 | 12J20 |
048 4 | 36 | 3 | 12J19 | 12J20 |
TXV Ranges:
- 12J18: 1.5 to 2.5 ton systems - Use on 2.5 ton (030) and lower systems.
- 12J19: 3 ton systems - Use down to 2 ton (024) systems.
- 12J20: 3.5 to 5 ton systems - Use down to 3 ton (036) systems.
AHRI STANDARD 210/240-2023
Standard Ratings are for cooling or heating capacities, including effects of circulating-fan heat, but not supplementary electric heat. Power input is used for calculating efficiency.
For units without indoor fans, ratings are adjusted by subtracting/adding 1,505 Btu/h per 1,000 SCFM.