CK40HT
Horizontal | Cased | Quantum™ Coil | TXV Furnished | R-410A / R-454B RESIDENTIAL PRODUCT SPECIFICATIONS (EHB)
INDOOR COILS 1.5 to 5 Tons
NOTE - Coils are furnished with a factory installed R-410A expansion valve. As an option, a R-454B expansion valve may be substituted. See page 5.
NOTE - See R-454B Refrigerant Conversion Table on page 5 for additional components required for conversion.
Model Number Identification
The model number CK40HT-36A-01 is structured as follows:
- Unit Type: C = Indoor Coil
- Series: 40 = Quantum™ Coil
- Cabinet: H = Horizontal Cased
- Metering Device: T = Factory installed Check/Expansion Valve for R-410A refrigerant (non-bleed port)
- Refrigerant Compatibility: K = R-454B Compatible
- Revision Level: 01 = R-410A TXV installed
- Cabinet Width: A = 14-1/2 in., B = 17-1/2 in., C = 21 in., D = 24-1/2 in.
- Nominal Cooling Capacity: 18 = 1.5 tons, 24 = 2 tons, 30 = 2.5 tons, 36 = 3 tons, 42 = 3.5 tons, 48 = 4 tons, 49 = 4 tons, 51/61 = 4/5 tons, 60 = 5 tons
Note: Furnaces with the same letter designation physically match the indoor coil.
Approvals and Warranty
Approvals
- Tested with matching air conditioners and heat pump units in the Lennox Research Laboratory environmental test room in accordance with AHRI Standard 210/240-2023.
- AHRI Certified system match-ups and expanded ratings available at www.LennoxPros.com.
- Air resistance tests conducted by Lennox Laboratory air test chamber.
NOTE: Coils can be field configured for use with R-454B refrigerant during the initial installation only. Coils may not be modified after initial installation.
Warranty
- All other covered components:
- Limited five years in residential installations.
- Limited one year in non-residential installations.
NOTE: Refer to Lennox® Basic Limited Warranty at www.Lennox.com for additional details.
Features
Applications
- 1.5 to 5 ton nominal sizes.
- Lennox designed horizontal indoor coils are easily installed with most Lennox horizontal furnaces.
- Factory installed R-410A check/expansion valve.
NOTE: Coils can be field converted for use with R-454B refrigerant.
Coil Construction (Quantum™ Coil)
- Lennox designed and fabricated coil.
- Aluminum tubing, hairpins, distributor, and header tubes.
- Copper refrigerant sweat connections on both liquid and suction lines for easy brazing.
- Ripple-edged aluminum fins.
- Lanced fins provide maximum exposure of fin surface to air stream.
- Helical grooved tubing provides superior heat transfer.
- Twin coil construction assembled in an "A" configuration for large surface area.
- High pressure testing ensures leak-proof construction.
Refrigerant Line Connections
- Copper refrigerant sweat connections on both liquid and suction lines for easy brazing.
- Lines extend outside of the cabinet for ease of connection.
- See dimension drawings for locations.
Anti-Microbial Drain Pan
- Non-corrosive, UV-resistant polymer drain pan with dual FPT drain connections.
- Anti-Microbial additive resists growth of mold and mildew on the drain pan, improving indoor air quality and reducing drain line blockage.
R-410A Check and Expansion Valve
- For use with R-410A systems.
- Wide range valve with Chatleff style fitting.
- Factory installed on all models.
R-454B Refrigerant Conversion
Additional Components are required for conversion to R-454B Refrigerant:
- Refrigerant Detection System (RDS) Coil Sensor Kit
- Refrigerant Detection System (RDS) Blower Control Board Kit
- R-454B Check and Expansion Valve
Optional Accessories
Refrigerant Detection System (RDS) Coil Sensor Kit
- Complies with UL 60335-2-40 approved standard.
- Required for all systems using R-454B refrigerant.
- Consists of Refrigerant Detection System (RDS) sensor, lineset sleeves, mounting brackets, and A2L labeling.
- Sensor ensures safe operation for systems equipped with R-454B refrigerant.
- Indoor sensor detects any refrigerant leaks.
- See R-454B Refrigerant Conversion Table on page 5.
Refrigerant Detection System (RDS) Blower Control Board
- Communicating Blower Control Board (Universal): Can be used universally with any Lennox® communicating furnace or any non-communicating 24 volt furnace.
- Non-Communicating Blower Control Board: Can be used with any non-communicating 24 volt furnace.
Standard Features (RDS System)
- Complies with UL 60335-2-40 approved standard.
- Required for all systems using R-454B refrigerant.
- Connects to the RDS sensor furnished with the RDS Coil Sensor Kit.
- Supports up to two RDS Sensors (factory setting).
- Used as interface between indoor unit and thermostat to control system in case of a refrigerant leak.
- Ensures safe operation for systems equipped with R-454B refrigerant.
- If a leak is detected, the refrigerant detection system will prevent compressor and heating operation until a leak is no longer detected.
- Refrigeration detection system also energizes the blower if a leak is detected to mitigate any concentrations of refrigerant from the conditioned space.
- Multi-color LED for system status and troubleshooting aid.
- Flashing LED codes for system status (Green/Blue) and diagnosing Sensor errors (Red).
- Alarm relay can trigger an external alarm if a leak is detected.
- Zone relay opens all zone dampers (if part of a zoning system) if a leak is detected.
- Power is disabled to non-communicating thermostats to prevent demand if a leak is detected.
- On system start-up, blower runs for five minutes and any thermostat demands are disabled.
- Dimensions (H x W x D): 7-7/16 x 7-7/16 x 2-1/2 (189 x 189 x 127 mm).
- See R-454B Refrigerant Conversion Table on page 5.
NOTE: Refer to the Installation Instructions for additional information.
R-454B Check and Expansion Valve
- For use with R-454B systems.
- Wide range valve with Chatleff style fitting.
- Replaces factory installed TXV, internal to cabinet.
- See Optional R-454B TXV Substitution table on page 5.
Cabinet
- Pre-painted heavy gauge steel.
- Insulated with thick fiberglass insulation.
- Flanges provided in outlet for ease of duct connection.
- Removable panels provide access to coil.
- Refrigerant lines extend outside of cabinet for easy installation.
Furnace Match-Up
- Coils exactly match corresponding furnaces with the same letter designation in model number.
- No adaptor required.
- Engaging holes furnished on cabinet for alignment with furnace.
Specifications
1.5 to 2 TON
Size | 18A | 24A | 24B |
Nominal Tonnage | 1.5 | 2 | 2 |
Furnace Cabinet Matching Letter Width | A | A | B |
Coil & Furnace Cabinet Width - in. | 14-1/2 | 14-1/2 | 17-1/2 |
Connections Liquid line (OD) sweat - in. | 3/8 | 3/8 | 3/8 |
Suction line (OD) sweat - in. | 7/8 | 7/8 | 7/8 |
Condensate drain (FPT) - in. | (2) 3/4 | (2) 3/4 | (2) 3/4 |
Indoor Coil Net face area - ft.² | 3.5 | 3.5 | 4.67 |
Tube diameter - in. | 3/8 | 3/8 | 3/8 |
Rows | 2 | 3 | 2 |
Fins - in. | 19 | 13 | 19 |
Shipping Data - lbs. | 44 | 46 | 50 |
2.5 to 3 TON
Size | 30A | 30B | 36A | 36B | 36C |
Nominal Tonnage | 2.5 | 2.5 | 3 | 3 | 3 |
Furnace Cabinet Matching Letter Width | A | B | A | B | C |
Coil & Furnace Cabinet Width - in. | 14-1/2 | 17-1/2 | 14-1/2 | 17-1/2 | 21 |
Connections Liquid line (OD) sweat - in. | 3/8 | 3/8 | 3/8 | 3/8 | 3/8 |
Suction line (OD) sweat - in. | 7/8 | 7/8 | 7/8 | 7/8 | 7/8 |
Condensate drain (FPT) - in. | (2) 3/4 | (2) 3/4 | (2) 3/4 | (2) 3/4 | (2) 3/4 |
Indoor Coil Net face area - ft.² | 4.33 | 4.67 | 3.5 | 4.67 | 5.83 |
Tube diameter - in. | 3/8 | 3/8 | 3/8 | 3/8 | 3/8 |
Rows | 3 | 3 | 3 | 2 | 2 |
Fins per inch | 16 | 13 | 13 | 18 | 18 |
Shipping Data - lbs. | 56 | 54 | 48 | 49 | 56 |
3.5 to 4 TON
Size | 42B | 42C | 48B | 48C |
Nominal Tonnage | 3.5 | 3.5 | 4 | 4 |
Furnace Cabinet Matching Letter Width | B | C | B | C |
Coil & Furnace Cabinet Width - in. | 17-1/2 | 21 | 17-1/2 | 21 |
Connections Liquid line (OD) sweat - in. | 3/8 | 3/8 | 3/8 | 3/8 |
Suction line (OD) sweat - in. | 7/8 | 7/8 | 7/8 | 7/8 |
Condensate drain (FPT) - in. | (2) 3/4 | (2) 3/4 | (2) 3/4 | (2) 3/4 |
Indoor Coil Net face area - ft.² | 5.78 | 5.83 | 5.78 | 5.83 |
Tube diameter - in. | 3/8 | 3/8 | 3/8 | 3/8 |
Rows | 4 | 3 | 3 | 3 |
Fins per inch | 13 | 13 | 13 | 13 |
Shipping Data - lbs. | 67 | 67 | 61 | 60 |
4 TO 5 TON
Size | 51/61C | 60D |
Nominal Tonnage | 4 / 5 | 5 |
Furnace Cabinet Matching Letter Width | C | D |
Coil & Furnace Cabinet Width - in. | 21 | 24-1/2 |
Connections Liquid line (OD) sweat - in. | 3/8 | 3/8 |
Suction line (OD) sweat - in. | 7/8 | 7/8 |
Condensate drain (FPT) - in. | (2) 3/4 | (2) 3/4 |
Indoor Coil Net face area - ft.² | 7.22 | 7.94 |
Tube diameter - in. | 3/8 | 3/8 |
Rows | 3 | 3 |
Fins per inch | 13 | 13 |
Shipping Data - lbs. | 70 | 79 |
Air Resistance
Total Air Resistance - in. w.g.
Air Volume cfm | 18A | 24A | 24B | 30A | 30B | 36A | 36B | 36C | 42B | 42C | 48B | 48C | 51/61C | 60D | ||||||||||||||
Dry Coil | Wet Coil | Dry Coil | Wet Coil | Dry Coil | Wet Coil | Dry Coil | Wet Coil | Dry Coil | Wet Coil | Dry Coil | Wet Coil | Dry Coil | Wet Coil | Dry Coil | Wet Coil | Dry Coil | Wet Coil | Dry Coil | Wet Coil | Dry Coil | Wet Coil | Dry Coil | Wet Coil | Dry Coil | Wet Coil | |||
200 | 0.02 | 0.02 | --- | --- | 0.04 | 0.05 | 0.03 | 0.04 | 0.04 | 0.05 | 0.02 | 0.02 | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | ||
400 | 0.05 | 0.06 | 0.04 | 0.05 | 0.05 | 0.06 | 0.05 | 0.06 | 0.05 | 0.06 | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | ||
600 | 0.09 | 0.11 | 0.09 | 0.11 | 0.07 | 0.09 | 0.09 | 0.10 | 0.09 | 0.11 | 0.05 | 0.06 | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | ||
800 | 0.15 | 0.17 | 0.15 | 0.19 | 0.09 | 0.11 | 0.15 | 0.17 | 0.15 | 0.17 | 0.09 | 0.11 | 0.15 | 0.18 | 0.08 | 0.10 | 0.06 | 0.08 | 0.10 | 0.10 | 0.06 | 0.06 | --- | --- | --- | --- | ||
1000 | 0.22 | 0.25 | 0.23 | 0.29 | 0.15 | 0.17 | 0.24 | 0.27 | 0.22 | 0.27 | 0.14 | 0.16 | 0.22 | 0.27 | 0.11 | 0.16 | 0.10 | 0.13 | 0.14 | 0.18 | 0.09 | 0.10 | 0.14 | 0.16 | --- | --- | ||
1200 | 0.32 | 0.40 | 0.21 | 0.23 | 0.34 | 0.38 | 0.30 | 0.39 | 0.32 | 0.40 | 0.19 | 0.23 | 0.30 | 0.39 | 0.16 | 0.21 | 0.15 | 0.18 | 0.20 | 0.25 | 0.15 | 0.16 | 0.19 | 0.23 | 0.15 | 0.16 | ||
1400 | 0.43 | 0.50 | 0.28 | 0.30 | 0.45 | 0.51 | 0.41 | 0.48 | 0.43 | 0.50 | 0.26 | 0.30 | 0.41 | 0.48 | 0.21 | 0.27 | 0.19 | 0.23 | 0.26 | 0.31 | 0.18 | 0.21 | 0.25 | 0.29 | 0.20 | 0.23 | ||
1600 | --- | --- | --- | --- | --- | --- | 0.53 | 0.63 | 0.53 | 0.63 | 0.27 | 0.35 | --- | --- | 0.24 | 0.31 | 0.34 | 0.36 | 0.26 | 0.28 | 0.30 | 0.38 | 0.27 | 0.30 | 0.25 | 0.29 | ||
1800 | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | 0.42 | 0.47 | 0.31 | 0.38 | 0.38 | 0.42 | 0.33 | 0.39 | 0.31 | 0.36 | ||
2000 | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | 0.39 | 0.49 | 0.40 | 0.44 | ||
2200 | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | 0.48 | 0.54 | ||
2400 | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |
Dimensions - Furnace/Coil Combined Dimensions
The following table details the combined dimensions for furnace and coil configurations.
Coil Size | A | B | ||
in. | mm | in. | mm | |
18A | 26-1/2 | 673 | 59-1/2 | 1511 |
24A | 26-1/2 | 673 | 59-1/2 | 1511 |
24B | 26-1/2 | 673 | 59-1/2 | 1511 |
30A | 31-1/2 | 800 | 64-1/2 | 1638 |
30B | 26-1/2 | 673 | 59-1/2 | 1511 |
36A | 26-1/2 | 673 | 59-1/2 | 1511 |
36B | 26-1/2 | 673 | 59-1/2 | 1511 |
36C | 26-1/2 | 673 | 59-1/2 | 1511 |
42B | 31-1/2 | 800 | 64-1/2 | 1638 |
42C | 26-1/2 | 673 | 59-1/2 | 1511 |
48B | 31-1/2 | 800 | 64-1/2 | 1638 |
48C | 26-1/2 | 673 | 59-1/2 | 1511 |
51/61C | 31-1/2 | 800 | 59-1/2 | 1511 |
60D | 31-1/2 | 800 | 64-1/2 | 1638 |
Dimensions
Diagrams show the physical layout and connection points. Key dimensions are provided in the table below.
- Note 1: Optional right-hand airflow requires a field fabricated 6 in. (152 mm) spacer in-between the furnace and coil.
Size | A | B | C | D | E | F | G | H | ||||||||
in. | mm | in. | mm | in. | mm | in. | mm | in. | mm | in. | mm | in. | mm | in. | mm | |
18A | 26-1/2 | 673 | 14-1/2 | 368 | 13 | 330 | 13-3/8 | 340 | 3-1/4 | 83 | 1-3/4 | 44 | 3-3/8 | 86 | 4-3/8 | 111 |
24A | 26-1/2 | 673 | 14-1/2 | 368 | 13 | 330 | 13-3/8 | 340 | 3-1/4 | 83 | 1-3/4 | 44 | 3-3/8 | 86 | 4-3/8 | 111 |
24B | 26-1/2 | 673 | 17-1/2 | 444 | 16 | 406 | 16-3/8 | 416 | 3-1/4 | 83 | 1-3/4 | 44 | 3-3/8 | 86 | 4-3/8 | 111 |
30A | 31-1/2 | 800 | 14-1/2 | 368 | 13 | 330 | 13-3/8 | 340 | 3-1/4 | 83 | 1-3/4 | 44 | 3-3/8 | 86 | 4-3/8 | 111 |
30B | 26-1/2 | 673 | 17-1/2 | 444 | 16 | 406 | 16-3/8 | 416 | 3-1/4 | 83 | 1-3/4 | 44 | 3-3/8 | 86 | 4-3/8 | 111 |
36A | 26-1/2 | 673 | 14-1/2 | 368 | 13 | 330 | 13-3/8 | 340 | 3-1/4 | 83 | 1-3/4 | 44 | 3-3/8 | 86 | 4-3/8 | 111 |
36B | 26-1/2 | 673 | 17-1/2 | 444 | 16 | 406 | 16-3/8 | 416 | 3-1/4 | 83 | 1-3/4 | 44 | 3-3/8 | 86 | 4-3/8 | 111 |
36C | 26-1/2 | 673 | 21 | 533 | 19-1/2 | 495 | 19-7/8 | 505 | 3-1/4 | 83 | 1-3/4 | 44 | 3-3/8 | 86 | 4-3/8 | 111 |
42B | 31-1/2 | 800 | 17-1/2 | 444 | 16 | 406 | 16-3/8 | 416 | 3-1/4 | 83 | 1-3/4 | 44 | 3-3/8 | 86 | 4-3/8 | 111 |
42C | 26-1/2 | 673 | 21 | 533 | 19-1/2 | 495 | 19-7/8 | 505 | 3-1/4 | 83 | 1-3/4 | 44 | 3-3/8 | 86 | 4-3/8 | 111 |
48B | 31-1/2 | 800 | 17-1/2 | 444 | 16 | 406 | 16-3/8 | 416 | 3-1/4 | 83 | 1-3/4 | 44 | 3-3/8 | 86 | 4-3/8 | 111 |
48C | 26-1/2 | 673 | 21 | 533 | 19-1/2 | 495 | 19-7/8 | 505 | 3-1/4 | 83 | 1-3/4 | 44 | 3-3/8 | 86 | 4-3/8 | 111 |
51/61C | 31-1/2 | 800 | 21 | 533 | 19-1/2 | 495 | 19-7/8 | 505 | 3-1/4 | 83 | 1-3/4 | 44 | 3-3/8 | 86 | 4-3/8 | 111 |
60D | 31-1/2 | 800 | 24-1/2 | 622 | 23 | 584 | 23-3/8 | 594 | 3-1/4 | 83 | 1-3/4 | 44 | 3-1/4 | 83 | 4-3/8 | 111 |
R-454B Refrigerant Conversion - Order Separately
Description | Order No. | |
Refrigerant Detection System (RDS) Coil Sensor Kit | 26Z69 | |
Refrigerant Detection System (RDS) Blower Control Board | Any Lennox® Communicating Furnace or any Non-Communicating 24V Furnace (Universal) | 27A03 |
Any Non-Communicating 24V Furnace | 27A02 |
NOTE - Communicating Blower Control Board and Sensor can be used universally with Lennox® communicating furnace or any non-communicating 24 volt furnace. Non-Communicating Blower Control Board and Sensor can be used with any non-communicating 24 volt furnace.
NOTE - Order R-454B Expansion Valve separately.
Optional R-454B TXV Substitution
NOTE: R-454B Coil Conversion Kit (26Z69) is required for TXV substitution and must be ordered separately.
Size | Order Number |
18 | 26Z70 |
24 | 26Z70 |
30 | 26Z70 |
36 | 26Z70 |
42 | 26Z71 |
48 | 26Z71 |
51/61 | 26Z71 |
60 | 26Z72 |