Lennox LRP15HPK Elite Series Packaged Heat Pump
Product Type: Residential Packaged Unit
Series: Elite® Series
Key Specifications: Two-Stage Compressor | Variable-Speed Blower | Single-Phase | R-454B | 60Hz
Performance: SEER2 - Up to 16.0 | HSPF2 - 7.2
Capacity Range: 2 to 5 Tons
Cooling Capacity: 23,000 to 57,000 Btuh
Heating Capacity: 21,400 to 58,000 Btuh
Optional Electric Heat: 5 to 20 kW
Refrigerant Compliance: 2025 Compliant Refrigerant
Model Number Identification
The model number LRP15HPK36VP-1-A breaks down as follows:
- Brand: L = Lennox
- Product Type: RP = Residential Packaged Unit
- Unit Type: HP = Packaged Heat Pump
- Refrigerant Type: K = R-454B
- Nominal SEER2: (Indicated by '15' in model number, e.g., LRP15)
- Nominal Cooling Capacity: 24 = 2 tons, 36 = 3 tons, 48 = 4 tons, 60 = 5 tons
- Blower: V = Variable Speed Blower Motor
- Voltage: P = 208/230V-1phase-60Hz
- Major Revision Sequence: 1 = 1st Generation
- Minor Revision Sequence: A = 1st Generation
Approvals and Warranty
Approvals
- AHRI Standard 210/240-2023 Certified
- Design Certified by ETL Intertek
- ENERGY STAR® certified units
- Cooling/Heating system rated according to DOE test procedures
- Heating ratings certified by AHRI
- ETL Certified for the U.S. and Canada
- Meets UL 60335-2-40 Refrigerant Detector Requirements
- Seismic Certification for 2018 International Building Code (IBC) and 2019 California Building Code (CBC) ASCE 7 (with Optional Seismic Strapping Kit)
- UL bonded for grounding
- Optional electric heaters are ETL listed
- Factory tested before shipment
Warranty
- Compressor: Limited ten years (residential), five years (non-residential)
- All other covered components: Limited five years (residential), one year (non-residential)
Refer to Lennox.com for full warranty details.
Features
Applications
Designed for outdoor installations at ground level or rooftop for residential applications. Units are not approved for zoning applications.
Refrigeration System
- R-454B Refrigerant: Low GWP, Zero ODP, Low Toxicity/Lower Flammability (A2L). Unit is factory pre-charged.
- Indoor and Outdoor Coils: Copper tube with aluminum fin coils.
- Anti-Microbial Indoor Coil Drain Pan: Resists mold and mildew, improves indoor air quality, reduces blockages. Includes drain pan overflow switch. Fully insulated to reduce condensation.
- Outdoor Coil Fan: Weather protected, heavy-duty motor with coated steel fan blades and corrosion-resistant guard. Internally mounted, totally enclosed motor.
- Four-Way Reversing Valve: Rapid changeover between cooling and heating based on pressure differential. Factory installed.
- High Pressure Switch: Protects system from high pressure conditions; automatic reset.
- Loss of Charge Switch: Shuts off unit if suction pressure falls too low, protecting against loss of charge and freeze-up.
- Service Valves: Fully serviceable brass valves in discharge and liquid lines.
- Low GWP Refrigerant Detection System (RDS): Complies with UL 60335-2-40. Factory installed. Detects refrigerant leaks, prevents compressor/heating operation, and activates blower to mitigate concentrations.
Compressor
- Two-Stage Scroll Compressor: High volumetric efficiency, uniform suction flow, constant discharge flow, quiet operation.
- Compressor Operation: Utilizes two involute spiral scrolls to compress gas in stages, achieving modulation by venting gas. Controlled by a 24-volt DC solenoid valve for staging (full-load or ~67% capacity). Loading/unloading is done "on the fly". Low gas pulses reduce operational sound. Motor is internally protected. Mounted on resilient rubber mounts for sound dampening.
Optional Accessories (Compressor)
- Compressor Crankcase Heater: Protects against refrigerant migration during low ambient operation.
- Compressor Hard Start Kit: May be required for low voltage conditions to increase starting torque.
- Compressor Timed-Off Control: Prevents short-cycling by allowing pressure equalization before restart (5-minute delay).
- Low Ambient Kit (40°F): Cycles outdoor fan to allow compressor operation in cooling mode at lower temperatures without icing. Requires crankcase heater and freezestat.
Supply Air Blower
- Direct Drive Blower: Statically and dynamically balanced.
- ECM Variable Speed Blower Motor: Multi-speed operation via ECM motor for consistent air volume across static pressure range. Controlled by blower control; speed is adjustable via jumper pins. Motor is resiliently mounted.
Indoor Air Quality (Option)
- Healthy Climate® PCO Accessory: Uses photocatalytic oxidation (PCO) technology to reduce airborne VOCs, odors. Mounted internally. Kit includes PCO cartridge, UVA lamp, etc. Cannot be used with Internal Filter Rack Kit.
- Internal Filter Rack Kits: Available for 1-inch thick filters. Filters not furnished. Cannot be used with PCO Accessory. Maximum filter efficiency MERV 11.
Electric Heat (Option)
- Field installable internal to unit cabinet.
- Available in 5-20 kW sizes.
- Helix wound nichrome heating elements for instant heat transfer.
- Cutoff limit control for over-temperature protection. Factory assembled.
Optional Accessories (Electric Heat)
- Single Point Power Supply Kits: Control box for single power supply connection to multi-circuit electric heat. Side power entry only.
Controls
- Refrigerant Detection System (RDS) Control: Monitors leak sensor, provides status via LED, includes test/reset button.
- Electronic Blower Control: Two stages (HEAT/COOL) with four air volume selections via jumper pins. ADJUST jumper for fine-tuning speed. Cooling Airflow Ramp Up feature improves moisture removal. Reduced Airflow Operation available for humidity control. Interface for thermostat with humidity control or humidistat.
- Defrost Control: Standard feature providing demand defrost based on coil sensing. Includes anti-short cycle protection and diagnostic LEDs.
- 24 Volt Transformer: 40VA transformer furnished and factory installed.
- Indoor Blower Off Delay Relay: Delays blower-off time during cooling cycle.
Cabinet
- Conditioned areas insulated with foil-faced insulation to minimize heat loss and reduce sound. Powder paint finish for durability. Easy service access.
- Steel louvered panels protect coils.
- Full perimeter heavy-gauge galvanized steel base rail with rigging holes and forklift slots.
- Raised edges around duct and power entry openings for water protection.
Airflow Choice
Units shipped with air openings sealed. Downflow or horizontal duct covers are removable.
Electrical Inlets and Service Valves
Standard field wiring inlets centrally located. Gauge ports inside the cabinet.
Optional Accessories (Cabinet/Installation)
- Base Rail Opening Closure Kit: Covers base rail openings.
- Bottom Gas Entry Kit: Allows gas piping through base pan.
- Bottom Power Entry Kit: Allows field wiring through base pan.
- Rectangular to Round Duct Adaptor Kits: For downflow or horizontal applications.
- Clip Curb (Full Perimeter): Interlocking tabs, no tools required, gasketed. Available in 8, 14, 18, 24 inch heights.
- Adjustable Pitch Roof Curb (Full Perimeter): For sloped roofs, adjustable from 2/12 to 6/12 pitch. Gasketed.
- All Curbs: IBC 2018 compliant, CBC 2019 compliant, seismic rated, high wind rating, 800 lbs max load.
- Strapping Kit - Seismic: Heavy-gauge galvanized steel brackets and hardware.
Specifications
Size (Tons) | Nominal Tonnage | Cooling Capacity (Btuh) | SEER2 | HSPF2 | Total Unit Watts (Cooling) | Heating Capacity (Btuh) | Total Unit Watts (Heating) | Sound Rating (dBA) | Refrigerant Charge |
---|---|---|---|---|---|---|---|---|---|
24 (2 Ton) | 2 | 23,000 | 16.0 | 7.2 | 1875 | 21,400 | 1800 | 71 | 4 lbs. 8 oz. |
36 (3 Ton) | 3 | 34,200 | 15.2 | 7.2 | 3025 | 33,200 | 2960 | 71 | 6 lbs. 13 oz. |
48 (4 Ton) | 4 | 45,000 | 15.2 | 7.2 | 3910 | 45,500 | 3930 | 74 | 8 lbs. 15 oz. |
60 (5 Ton) | 5 | 57,000 | 15.2 | 7.2 | 4950 | 58,000 | 5030 | 74 | 9 lbs. 4 oz. |
Compressor Details
Size | Net Face Area (ft²) | Tube Diameter (in.) | Rows | Fins (in.) | Blower HP | Blower Diameter (in.) | Blower Blades |
---|---|---|---|---|---|---|---|
24 | 16.3 | 5/16 | 1 | 22 | 1/2 | 22 | 3 |
36 | 15.5 | 5/16 | 2 | 22 | 1/2 | 22 | 3 |
48 | 18.6 | 5/16 | 2 | 22 | 1/2 | 24 | 3 |
60 | 18.6 | 5/16 | 2 | 22 | 3/4 | 24 | 3 |
Electrical Data
Size (Tons) | Max Overcurrent Protection (MOCP) Amps | Min Circuit Ampacity (MCA) | Compressor Rated Load Amps | Outdoor Coil Fan Motor Full Load Amps | Indoor Blower Motor Full Load Amps |
---|---|---|---|---|---|
24 (2 Ton) | 25 | 17.1 | 10.2 | 2.3 | 2.0 |
36 (3 Ton) | 40 | 25.1 | 15.3 | 2.3 | 3.7 |
48 (4 Ton) | 50 | 31.7 | 19.5 | 3.6 | 3.8 |
60 (5 Ton) | 60 | 39.7 | 25.2 | 3.6 | 4.6 |
Dimensions and Weights
Size (Tons) | Net Weight (lbs) | Shipping Weight (lbs) | Height (in.) | Width (in.) | Depth (in.) |
---|---|---|---|---|---|
24 (2 Ton) | 411 | 421 | 47-5/8 | 47-5/8 | 40-7/8 |
36 (3 Ton) | 446 | 456 | 47-5/8 | 47-5/8 | 40-7/8 |
48 (4 Ton) | 526 | 536 | 55-1/4 | 56-1/8 | 44-7/8 |
60 (5 Ton) | 541 | 551 | 55-1/4 | 56-1/8 | 44-7/8 |
Note: Detailed dimensions for various components and installation clearances are available in the full document.
Cooling and Heating Ratings Summary
Comprehensive cooling and heating performance data is provided in tables, detailing capacities (Btuh) and efficiencies (SEER2, HSPF2, COP) across various outdoor and indoor air temperatures and volumes (cfm). These tables are extensive and specific to each tonnage size (2, 3, 4, and 5 tons). For precise values, refer to the original document.
Example Heating Ratings (Btuh):
Model | 0/0 °F | 17/15 °F | 47/43 °F | 62/56 °F |
---|---|---|---|---|
LRP15HPK24 | 6,800 | 12,000 | 22,000 | 27,000 |
LRP15HPK36 | 13,600 | 19,900 | 34,100 | 41,200 |
LRP15HPK48 | 19,100 | 28,300 | 48,100 | 58,000 |
LRP15HPK60 | 22,500 | 36,800 | 61,100 | 73,300 |
Note: Values based on 0.50 in. w.g. external static pressure.
Optional Accessories
A variety of optional accessories are available to enhance functionality, including:
- Controls: E30 Smart Wi-Fi Thermostat, Remote Outdoor Temperature Sensor.
- Cooling System: Compressor Crankcase Heater, Hard Start Kit, Timed-Off Control, Low Ambient Kit.
- Cabinet: Base Rail Opening Closure Kit, Rectangular to Round Duct Adaptor Kits.
- Electrical: Bottom Power Entry Kit.
- Electric Heat: Various kW sizes (5-20 kW), Single Point Power Supply Kits.
- Indoor Air Quality: Healthy Climate® PCO Accessory, Internal Filter Rack Kits.
- Roof Curbs: Clip Curbs (various heights), Adjustable Pitch Roof Curbs (Welded/Clip), Seismic Strapping Kits.
Revisions
Description of Change: Removed Hurricane Strapping Kits from Optional Accessories.