Elitech RC-51H User Manual

Multi-use Temperature & Humidity Data Logger

Product Overview

This temperature and humidity data logger is mainly used in fields such as medicine, food, life science, flowers, breeding industry, ice chests, containers, shady cabinets, medical cabinets, refrigerators, laboratories, and greenhouses. The RC-51H is plug-and-play and can directly generate a data report without needing to install data management software. Data can still be read even if the battery runs out.

Structure Description

The device features a clear LCD screen for displaying readings and status indicators. Key components include:

The LCD screen displays various indicators:

The product label typically includes:

Parameter Instruction

Users can reconfigure parameters using the data management software. This process may clear original parameters and data.

Alarm Threshold: Supports 3 upper temperature limits, 2 lower temperature limits, 1 upper humidity limit, and 1 lower humidity limit.

Alarm Zone: The range of readings that are considered outside the normal operating conditions.

Alarm Type: Can be 'Single' (records the duration of a single over-limit event) or 'Cumulative' (records the total time spent over the limit).

Alarm Delay: The logger does not trigger an alarm immediately when readings enter the alarm zone; it waits for the specified delay time to elapse.

MKT (Mean Kinetic Temperature): An evaluation method for assessing the impact of temperature fluctuations on stored goods.

Operating Instructions

The data logger can be stopped by software or by pressing the stop button. Users can stop the logger by clicking the stop button in the data management software.

Logger Operation and Indicators
ActionParameter ConfigurationOperationLCD IndicatorIndicator
StartInstant-onDisconnect to USBΓECGreen indicator flashes 5 times.
Timing startDisconnect to USBSEACEGreen indicator flashes 5 times.
Manual startPress and hold for 5sΓECGreen indicator flashes 5 times.
StopManual stopPress and hold for 5sSEACERed indicator flashes 5 times.
Stop (Max Capacity)Over-Max-record-capacity (disable manual stop)Reach the Max capacityΓECRed indicator flashes 5 times.
Over-Max-record-capacity (Enable manual stop)Reach the Max capacity or press and hold the button for 5sSEACERed indicator flashes 5 times.
ViewPress and release the button. Refer to the menu and status indicator.

Menu and Status Indicator

The logger's LCD screen displays various menus and status indicators. The following tables detail these:

Menu Descriptions:

MenuDescriptionExampleMenuDescriptionExample
1Countdown of the (timing) start03:42 (HH:MM)6Average humidity value4.5
2Current temperature value2.37Maximum temperature value9.8
3Current humidity value2.38Maximum humidity value9.8
4Points of the records320009Minimum temperature value2.7
5Average temperature value4.810Minimum humidity value2.7

Combined Indicators and Other Status:

DisplayDescriptionDisplayDescription
AActual stop modeBAlarm status
CSet stop modeDTemperature alarm zone status
ETotal times exceeding temperature alarm thresholdFTotal duration exceeding temperature alarm threshold
GAlarm delay and alarm typeHAlarm threshold and temperature alarm zones
IVertical coordinate unit of data graphJAverage humidity value
KAlarm threshold lineLAlarm threshold
MRecord data curve (black=temperature, deep green=humidity)NDocument name (serial number & usage ID)
ORecord time range on current pagePRecords when date changes (date & temp/humidity)
QRecords when date does not change (time & temp/humidity)

Other status indicators include 'Null value' and 'Clear data'.

Technical Specifications

Specifications of the RC-51H Data Logger
ParameterValueParameterValue
Multi-UseYesCertificationsEN12830, CE, RoHS
Temperature Range-30°C to 70°CValidation Certificate HardcopyAutomatic PDF report
Humidity Range10%~95% RHReport GenerationAutomatic PDF report
Temperature & Humidity Accuracy±0.5°C (-20°C/+40°C); ±1.0°C (other range)
±3%RH (25°C, 20%~90%RH), ±5%RH (other range)
Temperature & Humidity Resolution0.1°C (Temperature)
0.1%RH (Humidity)
Data Storage Capacity32,000 readingsPassword ProtectionOptional on request
SoftwarePDF/ElitechLog Win or Mac (latest version)ReprogrammableWith free Elitech Win or MAC software
Connection InterfaceUSB 2.0, A-TypeAlarm ConfigurationOptional, up to 5 points, Humidity only supports upper and lower limit alarm
Shelf Life/Battery2 years¹ / ER14250 button cellDimensions131mm x 24mm x 7mm (L x D)
Recording Interval15 minutes (standard)
Startup ModeButton or software
Stop ModeButton, software or stop when full
Weight60g

¹ Depending on optimal storage conditions (±15°C to +23°C / 45% to 75% RH)

Viewing Data

After the data logger is connected to a computer's USB port, it automatically generates a PDF data report. During report creation, the red and green indicators flash alternately, and the LCD screen shows the progress. Once creation is complete, both indicators light up simultaneously, allowing users to view the report. This process typically takes no more than 4 minutes.

Steps to view data:

  1. Rotate the transparent cap in the direction of the arrow and remove it.
  2. Insert the data logger into the computer's USB port to view the data report.

The generated report will be a PDF file (e.g., XXX.pdf).

What's Included

Manufacturer Information

Elitech Technology, Inc.
1551 McCarthy Blvd, Suite 112, Milpitas, CA 95035 USA
Tel: (+1)408-844-4070
Sales: sales@elitechus.com
Support: support@elitechus.com
Website: www.elitechus.com
Software Download: elitechus.com/download/software

Elitech (UK) Limited
2 Chandlers Mews, London, E14 8LA UK
Tel: (+44)203-645-1002
Sales: sales@elitech.uk.com
Support: service@elitech.uk.com
Website: www.elitech.uk.com
Software Download: elitechonline.co.uk/software

Version: V1.0

PDF preview unavailable. Download the PDF instead.

C1JpOARYFPS PDFium PDFium

Related Documents

Preview Elitech RC-51H User Manual: Temperature & Humidity Data Logger Guide
Comprehensive user manual for the Elitech RC-51H multi-use temperature and humidity data logger. Learn about its features, operation, technical specifications, and how to use it for monitoring and recording environmental data.
Preview Elitech RC-4HC Temperature and Humidity Data Logger Specifications
Comprehensive specifications and features for the Elitech RC-4HC PDF temperature and humidity data logger, detailing its capabilities for cold chain monitoring, industrial applications, and data export.
Preview Elitech RC-51H Multi-use Temperature & Humidity Data Logger User Manual
User manual for the Elitech RC-51H multi-use temperature and humidity data logger. Covers product overview, structure, parameter settings, operating instructions, technical specifications, indicator status, menu functions, battery replacement, and report details.
Preview Elitech RC-51H User Manual: Temperature & Humidity Data Logger
Comprehensive user manual for the Elitech RC-51H multi-use temperature and humidity data logger. Covers product overview, structure, parameters, operating instructions, technical specifications, report generation, and battery replacement.
Preview Elitech RC-61/GSP-6 User Manual: Temperature and Humidity Data Logger
This user manual provides comprehensive guidance for the Elitech RC-61/GSP-6 temperature and humidity data logger, covering its features, specifications, operation, and important usage notes for cold chain monitoring applications.
Preview Elitech RC-4 Series Temperature and Humidity Data Loggers - User Manual
Comprehensive user manual for Elitech RC-4 and RC-4HC series temperature and humidity data loggers. Covers specifications, operation, setup, and troubleshooting for cold chain monitoring.
Preview Elitech RC-51H User Manual: Temperature and Humidity Data Logger
Comprehensive user manual for the Elitech RC-51H, a multi-use temperature and humidity data logger. Learn about its features, specifications, operating instructions, and data reporting.
Preview Elitech RC-51 Multi-use Temperature Data Logger: Specifications & User Guide
Comprehensive technical specifications, usage instructions, and overview for the Elitech RC-51 multi-use temperature data logger, designed for monitoring food, pharmaceuticals, and chemicals in storage and transportation.