This temperature and humidity data logger is mainly used in fields such as medicine, food, life science, flowers, breeding industry, ice chests, containers, shady cabinets, medical cabinets, refrigerators, laboratories, and greenhouses. The RC-51H is plug-and-play and can directly generate a data report without needing to install data management software. Data can still be read even if the battery runs out.
The device features a clear LCD screen for displaying readings and status indicators. Key components include:
The LCD screen displays various indicators:
The product label typically includes:
Users can reconfigure parameters using the data management software. This process may clear original parameters and data.
Alarm Threshold: Supports 3 upper temperature limits, 2 lower temperature limits, 1 upper humidity limit, and 1 lower humidity limit.
Alarm Zone: The range of readings that are considered outside the normal operating conditions.
Alarm Type: Can be 'Single' (records the duration of a single over-limit event) or 'Cumulative' (records the total time spent over the limit).
Alarm Delay: The logger does not trigger an alarm immediately when readings enter the alarm zone; it waits for the specified delay time to elapse.
MKT (Mean Kinetic Temperature): An evaluation method for assessing the impact of temperature fluctuations on stored goods.
The data logger can be stopped by software or by pressing the stop button. Users can stop the logger by clicking the stop button in the data management software.
Action | Parameter Configuration | Operation | LCD Indicator | Indicator |
---|---|---|---|---|
Start | Instant-on | Disconnect to USB | ΓEC | Green indicator flashes 5 times. |
Timing start | Disconnect to USB | SEACE | Green indicator flashes 5 times. | |
Manual start | Press and hold for 5s | ΓEC | Green indicator flashes 5 times. | |
Stop | Manual stop | Press and hold for 5s | SEACE | Red indicator flashes 5 times. |
Stop (Max Capacity) | Over-Max-record-capacity (disable manual stop) | Reach the Max capacity | ΓEC | Red indicator flashes 5 times. |
Over-Max-record-capacity (Enable manual stop) | Reach the Max capacity or press and hold the button for 5s | SEACE | Red indicator flashes 5 times. | |
View | Press and release the button. Refer to the menu and status indicator. |
The logger's LCD screen displays various menus and status indicators. The following tables detail these:
Menu | Description | Example | Menu | Description | Example |
---|---|---|---|---|---|
1 | Countdown of the (timing) start | 03:42 (HH:MM) | 6 | Average humidity value | 4.5 |
2 | Current temperature value | 2.3 | 7 | Maximum temperature value | 9.8 |
3 | Current humidity value | 2.3 | 8 | Maximum humidity value | 9.8 |
4 | Points of the records | 32000 | 9 | Minimum temperature value | 2.7 |
5 | Average temperature value | 4.8 | 10 | Minimum humidity value | 2.7 |
Display | Description | Display | Description |
---|---|---|---|
A | Actual stop mode | B | Alarm status |
C | Set stop mode | D | Temperature alarm zone status |
E | Total times exceeding temperature alarm threshold | F | Total duration exceeding temperature alarm threshold |
G | Alarm delay and alarm type | H | Alarm threshold and temperature alarm zones |
I | Vertical coordinate unit of data graph | J | Average humidity value |
K | Alarm threshold line | L | Alarm threshold |
M | Record data curve (black=temperature, deep green=humidity) | N | Document name (serial number & usage ID) |
O | Record time range on current page | P | Records when date changes (date & temp/humidity) |
Q | Records when date does not change (time & temp/humidity) |
Other status indicators include 'Null value' and 'Clear data'.
Parameter | Value | Parameter | Value |
---|---|---|---|
Multi-Use | Yes | Certifications | EN12830, CE, RoHS |
Temperature Range | -30°C to 70°C | Validation Certificate Hardcopy | Automatic PDF report |
Humidity Range | 10%~95% RH | Report Generation | Automatic PDF report |
Temperature & Humidity Accuracy | ±0.5°C (-20°C/+40°C); ±1.0°C (other range) ±3%RH (25°C, 20%~90%RH), ±5%RH (other range) | Temperature & Humidity Resolution | 0.1°C (Temperature) 0.1%RH (Humidity) |
Data Storage Capacity | 32,000 readings | Password Protection | Optional on request |
Software | PDF/ElitechLog Win or Mac (latest version) | Reprogrammable | With free Elitech Win or MAC software |
Connection Interface | USB 2.0, A-Type | Alarm Configuration | Optional, up to 5 points, Humidity only supports upper and lower limit alarm |
Shelf Life/Battery | 2 years¹ / ER14250 button cell | Dimensions | 131mm x 24mm x 7mm (L x D) |
Recording Interval | 15 minutes (standard) | ||
Startup Mode | Button or software | ||
Stop Mode | Button, software or stop when full | ||
Weight | 60g |
¹ Depending on optimal storage conditions (±15°C to +23°C / 45% to 75% RH)
After the data logger is connected to a computer's USB port, it automatically generates a PDF data report. During report creation, the red and green indicators flash alternately, and the LCD screen shows the progress. Once creation is complete, both indicators light up simultaneously, allowing users to view the report. This process typically takes no more than 4 minutes.
Steps to view data:
The generated report will be a PDF file (e.g., XXX.pdf).
Elitech Technology, Inc.
1551 McCarthy Blvd, Suite 112, Milpitas, CA 95035 USA
Tel: (+1)408-844-4070
Sales: sales@elitechus.com
Support: support@elitechus.com
Website: www.elitechus.com
Software Download: elitechus.com/download/software
Elitech (UK) Limited
2 Chandlers Mews, London, E14 8LA UK
Tel: (+44)203-645-1002
Sales: sales@elitech.uk.com
Support: service@elitech.uk.com
Website: www.elitech.uk.com
Software Download: elitechonline.co.uk/software
Version: V1.0
![]() |
Elitech RC-51H User Manual: Temperature & Humidity Data Logger Guide Comprehensive user manual for the Elitech RC-51H multi-use temperature and humidity data logger. Learn about its features, operation, technical specifications, and how to use it for monitoring and recording environmental data. |
![]() |
Elitech RC-4HC Temperature and Humidity Data Logger Specifications Comprehensive specifications and features for the Elitech RC-4HC PDF temperature and humidity data logger, detailing its capabilities for cold chain monitoring, industrial applications, and data export. |
![]() |
Elitech RC-51H Multi-use Temperature & Humidity Data Logger User Manual User manual for the Elitech RC-51H multi-use temperature and humidity data logger. Covers product overview, structure, parameter settings, operating instructions, technical specifications, indicator status, menu functions, battery replacement, and report details. |
![]() |
Elitech RC-51H User Manual: Temperature & Humidity Data Logger Comprehensive user manual for the Elitech RC-51H multi-use temperature and humidity data logger. Covers product overview, structure, parameters, operating instructions, technical specifications, report generation, and battery replacement. |
![]() |
Elitech RC-61/GSP-6 User Manual: Temperature and Humidity Data Logger This user manual provides comprehensive guidance for the Elitech RC-61/GSP-6 temperature and humidity data logger, covering its features, specifications, operation, and important usage notes for cold chain monitoring applications. |
![]() |
Elitech RC-4 Series Temperature and Humidity Data Loggers - User Manual Comprehensive user manual for Elitech RC-4 and RC-4HC series temperature and humidity data loggers. Covers specifications, operation, setup, and troubleshooting for cold chain monitoring. |
![]() |
Elitech RC-51H User Manual: Temperature and Humidity Data Logger Comprehensive user manual for the Elitech RC-51H, a multi-use temperature and humidity data logger. Learn about its features, specifications, operating instructions, and data reporting. |
![]() |
Elitech RC-51 Multi-use Temperature Data Logger: Specifications & User Guide Comprehensive technical specifications, usage instructions, and overview for the Elitech RC-51 multi-use temperature data logger, designed for monitoring food, pharmaceuticals, and chemicals in storage and transportation. |