Daikin Submittal Data Sheet
KRP067A41E/KRP980B1/KRP980B2E Adaptor for Wired Controller
Project Information
Project Name: [Not Specified]
Location: [Not Specified]
Engineer: [Not Specified]
Submitted to: [Not Specified]
Submitted by: [Not Specified]
Reference: [Not Specified]
Approval: [Not Specified]
Date: [Not Specified]
Construction: [Not Specified]
Unit #: [Not Specified]
Drawing #: [Not Specified]
Model Compatibility
Part Number | Compatible Indoor Unit Models |
---|---|
KRP067A41E | FTX09NMVJU, FTX12NMVJU, FTK09NMVJU, FTK12NMVJU, FTXN09NMVJU, FTXN12NMVJU, FTKN09NMVJU, FTKN12NMVJU |
KRP980B1 | FTXN_KEVJU |
KRP980B2E | FTX18NMVJU, FTX24NMVJU, FTK18NMVJU, FTK24NMVJU, FTXN18NMVJU, FTXN24NMVJU, FTKN18NMVJU, FTKN24NMVJU |
Specifications
Model | KRP067A41E/KRP980B1/KRP980B2E |
Description | Adaptor for Wired Controllers |
Maximum Connections | 1 indoor unit |
Dimensions | 4.25 x 1.88 x 1.30 inches |
Mounting | Inside the indoor unit |
Product Image
A small, rectangular electronic adapter with various connectors and labels, including 'AR2427H EX672-3 REV:', 'SPACER', '5602 SPACER', and 'S21'.
Features
- Provides a S21 interface for compatible indoor units lacking a built-in S21 connector.
- Connects the compatible indoor unit with one of the following controller/adaptors:
- BRC944B2 - Wired Remote Controller
- KRP928BB2S - RA Interface Adaptor for DIII-Net
- KRP413AB1S - Wiring Adaptor for Timer Clock / Remote Controller
- BRP072A43 - Wireless LAN Connect Adaptor (includes an Adaptor for Wired Controller already)
Note: An additional cable (BRCW901A08/ DACA-BRCW901P10/ DACA-BRCW901P25) is required if both BRC944B2 and KRP928BB2S are connected. The Wired Remote Controller Kit BRC944B2-A08 includes both BRCW901A08 and the BRCW901A08.
Wiring Diagrams
Diagram 1: Connection to One Controller/Adaptor
This diagram illustrates the adaptor's connection within the indoor unit. The 'Adaptor for Wired Controller' is shown connected to the 'S21' port on the 'PCB of indoor unit'. The adaptor also features an 'Option' port, which can be connected to one of the following: BRC944B2, KRP928BB2S, BRP072A43, or KRP413AB1S. The entire setup is located 'Inside indoor unit'.
Diagram 2: Connection to BRC944B2 and KRP928BB2S Together
This diagram details the combined connection of the KRP928BB2S and BRC944B2 units. The KRP928BB2S unit, featuring switches SW1, SW2, SW3, and LED1, is connected to the 'Adaptor for Wired Controller' via the 'S21' port. The adaptor is then connected to the 'PCB of indoor unit'. The BRC944B2 unit is shown connected to the 'Adaptor for Wired Controller' as well. Both components are situated 'Inside indoor unit'. The diagram also shows various terminals and connections on the KRP928BB2S, including S1, S5, S6, S8, S16, S19, F1, F2, and a test terminal. The BRC944B2 unit is depicted with its own set of terminals.
Note: An additional cable (BRCW901A08/DACA-BRCW901P10/DACA-BRCW901P25) is needed if both BRC944B2 and KRP928BB2S are connected. The Wired Remote Controller Kit BRC944B2-A08 includes both BRCW901A08 and the BRCW901A08.
Documentation
Documentation available on www.daikincity.com and/or www.daikinac.com:
- Submittal
- Installation Manual