DAIKIN ONE+ TRANSLATION ADAPTOR
INSTALLATION INSTRUCTIONS
Manufacturer: DAIKIN MANUFACTURING COMPANY, L.P.
Address: 19001 Kermier Rd. Waller, TX 77484
Website: www.daikincomfort.com
Part Number: IOD-7134
Date: July 2020
WARNINGS
HIGH VOLTAGE
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. ⚡
PROP 65 WARNING FOR CALIFORNIA CONSUMERS
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
Safety Precautions
- Only qualified personnel can carry out the equipment installation.
- Make sure to turn off the power supply before starting the wiring work and do not turn on until the work is completed. Read the installation manual and wiring diagram of the indoor unit when carrying out the work.
- Make sure to securely connect the connectors; unsecured connections may result in improper communication and/or malfunction.
- Do not splice wires.
Items in the Packaging
Item | Description | Qty. |
---|---|---|
Translation Adaptor with power supply wire | 1 | |
P1P2 connector (removable) | 1 | |
Thermostat connector (removable) | 1 | |
Front cover | 1 | |
Adaptor mounting plate | 1 | |
Screws | 4 | |
Adhesive tape | 1 | |
Daikin One+ Thermostat | 1 | |
Thermostat terminal plate | 1 | |
Thermostat mounting plate | 1 | |
S21 wiring cable | 1 | |
Welcome documents | 1 |
Product Overview
The Daikin ONE+ Translation Adaptor is used to connect the Daikin ONE+ thermostat with Daikin VRV, SkyAir, Single-Zone, and Multi-zone systems.
Note: The Daikin ONE+ Smart Thermostat cannot be used together with other wireless or wired remote controllers. For retrofit projects, please remove any other remote controller(s) before installation.
Dimension Drawings
1. Translation Adaptor
The Translation Adaptor is a rectangular device with approximate dimensions of 6.8 inches (length) x 3.4 inches (width) x 0.8 inches (depth). It features various terminals and slots for wiring, including S21 Terminal, P1P2 Terminal, and a Power Indicator.
2. Mounting Plate
The Mounting Plate is a flat rectangular piece designed to attach the adaptor to a surface. It has two screw holes and a recess for adhesive tape.
Specification
Specification | Details |
---|---|
Model | DTST-ONE-ADA-A |
Description | Daikin ONE+ Smart Thermostat for VRV and Ductless Products |
Maximum Connections (S21) | 1 for S21 Indoor Units (1 remote controller group) (cannot use together with another wireless remote controller or wired remote controller) |
Maximum Connections (P1P2) | 16 for P1P2 Indoor Units (1 remote controller group) (cannot use together with another wireless remote controller or wired remote controller) |
Power Wire | 5.5 ft (included) |
Thermostat Wire | 125 ft (Field-supplied, 18AWG, 4-conductor non-shielded stranded wire) |
Max Wiring Length (S21 Communication Wire) | 6 ft (included) |
Max Wiring Length (P1P2 Communication Wire) | 6 ft* for the wire between the Translation Adaptor and the indoor unit terminal block (Field-supplied, 18AWG, 2-conductor non-shielded stranded wire) |
Power Supply | Translation Adaptor: 110-240 VAC; Thermostat: Obtained from the Translation Adaptor |
Dimensions (Translation Adaptor) | 6.8" x 3.4" x 0.8" |
Dimensions (Thermostat Adaptor) | 2.72" x 7.26" x 0.43" |
Weight (Thermostat) | 10.5 oz |
Weight (Thermostat Adaptor) | 18.4 oz |
Storage Temperature | 32°F to 120°F |
Operation Temperature (Thermostat) | 32°F to 120°F |
Operation Temperature (Thermostat Adaptor) | -40°F to 150°F |
Humidity | 20 to 95% RH (non-condensing) |
*P1P2 wire has a maximum wiring length of 1640 feet.
Selection of Mounting Location
The recommended mounting location and approach vary for different Daikin indoor unit types.
1. Wall-mounted unit
Applicable models: CTXS, FAQ, FTK_N, FTX_N, FTX_U, FTXG, FTXR, FTXS, FXAQ
For wall-mounted units, if the refrigerant piping is installed on the right side and the refrigerant piping chase inside the indoor unit is not occupied, it is recommended to mount the Translation Adaptor inside the indoor unit so that the Adaptor is concealed. Otherwise, the Adaptor will need to be mounted outside of the indoor unit.
- Mounting inside the indoor unit piping chase: Make use of the extra space left by the indoor unit mounting plate. Mount the backplate of the Adaptor to the wall. The extra space varies for different indoor unit models; use the largest available space for mounting. Ensure the high voltage power side of the Adaptor faces towards the indoor unit electrical box. When installed inside the piping chase, the front cover is optional. For some wall-mount units, removal of the front plate may be required to fit inside the piping chase. If the Adaptor is mounted inside the unit, there is no need to install the Adaptor cover.
- Mounting outside of the indoor unit: If the refrigerant piping is left-side installed and the piping chase is occupied by the refrigerant piping, the Translation Adaptor needs to be mounted outside the indoor unit. Select a location that provides access to the indoor unit electrical box, minimizing the view of the Adaptor and wiring cables.
2. Ducted and Air Handler Unit
Applicable models: CDXS, CXTQ, FBQ, FDMQ, FDXS, FTQ, FXDQ, FXMQ, FXSQ, FXTQ
For the ducted indoor unit, the Translation Adaptor can be mounted to the side or on top of the indoor unit using the adhesive tape. The translator box can also be mounted to a nearby sturdy surface. Select a location that provides access to the indoor unit electrical box.
3. Ceiling Cassette Units
Applicable models: FCQ, FFQ, FXEQ, FXFQ, FXZQ
For the ceiling cassette indoor unit, the Translation Adaptor can be mounted on top or the side of the indoor unit using the adhesive tape. The translator box can also be mounted on a surface above the ceiling using the provided screws. Select a location that provides access to the indoor unit electrical box.
4. Ceiling Suspended Units
Applicable models: FHQ, FXHQ, FXUQ
For the ceiling suspended indoor units, the Translation Adaptor can be mounted on top of the indoor unit by the adhesive tape (for FXUQ). The Adaptor can also be mounted above the ceiling. Select a location that provides access to the indoor unit electrical box.
5. Floor-mounted and Floor Standing Units
Applicable models: FVXS, FXLQ, FXMQ, FXNQ
For floor-mounted and floor standing units, the translator box shall be mounted by the side of the indoor unit. Select a location that minimizes the view of the Adaptor and the wiring, while providing access to the indoor unit electrical box.
Mounting
The Translation Adaptor provides two mounting approaches. For wall-mounted units, the front cover is optional if the adaptor is mounted inside the piping chase.
1. Mount with two screws
Screws (provided) are used to mount the Adaptor to the available wall surface. Do not use screws to mount the Adaptor directly to the indoor unit. Use the two screws to mount the backplate onto the selected surface.
Diagram Description: Shows the mounting plate being attached to a wall with two screws, followed by the adaptor being attached to the mounting plate, and optionally the front cover.
2. Mount with double-sided adhesive tape
Double-sided adhesive tape is used to mount the translator box onto the indoor unit directly. The mounting plate has a recess to place the adhesive tape to minimize the gap between the mounting plate and the mounting surface. Use the text “APPLY OPTIONAL ADHESIVE STRIP HERE” to identify the back side of the mounting plate.
To ensure excellent durability performance of the adhesive tape, follow these steps:
- Make sure the mounting surface is clean. It is suggested to use a 50:50 mixture of isopropyl alcohol and water to clean the surface to remove any dust or oils. If the surface is not properly cleaned, the adhesive will not create a chemical adhesive bond.
- For flat surfaces, use the adhesive tape provided in the package. Apply firm pressure for 30 seconds to develop better adhesive contact and improve adhesive chemical bond strength.
- For non-flat surface applications, the installer may need to use thicker adhesive tape, such as 3M Super Strength Molding Tape 03609, to provide more contact compliance on curved surfaces.
Diagram Description: Shows the mounting plate with adhesive tape applied to its recess, then attached to a surface, followed by the adaptor being attached to the mounting plate, and optionally the front cover.
Wiring
1. Overview
The translator box is connected between the indoor unit and the Daikin ONE+ Thermostat. It obtains power from the indoor unit power termination or an external power source.
For S21 Indoor Units
Diagram Description: Illustrates the wiring for S21 indoor units. It shows the Thermostat terminal plate connecting to the Translation Adaptor, which then connects via S21 connector to the Indoor unit/Interface Adaptor. Power is supplied from the Indoor unit power supply terminal (110-230VAC).
For P1P2 Indoor Units
Diagram Description: Illustrates the wiring for P1P2 indoor units. It shows the Thermostat terminal plate connecting to the Translation Adaptor, which then connects via P1P2 terminal to the Indoor unit terminal block. Power is supplied from the Indoor unit power supply terminal (110-230VAC).
Wiring Requirements
Wire Name | Type | Connected to | Max Length |
---|---|---|---|
High-Voltage Power Line | 3-wire, Included in the package | Indoor unit power terminal or external power source | 5 ½ ft |
Thermostat Wire | Field-supplied, 18 AWG, 4-conductor non-shielded stranded wire | Daikin ONE+ Thermostat | 125 ft |
S21 Communication Wire | 5-conductor wire with connectors, included in the package | S21 Terminal on the indoor unit PCB or S21 Terminal on the Interface adaptor | 6 ft |
P1P2 Communication Wire | Field-supplied, 18 AWG, 2-conductor non-shielded stranded wire | P1P2 Terminal on the indoor unit | 6 ft* |
*P1P2 wire has a maximum wiring length of 1640 feet.
Communication Terminal Usage
Only one communication terminal (S21 or P1P2) shall be used per indoor unit. Never use both simultaneously.
Indoor Unit Model | Communication Terminal |
---|---|
CDXS, CTXS, FDXS, FTK_N, FTX_N, FTX_U, FTXG, FTXR, FTXS, FVXS | S21 Terminal |
CXTQ, FAQ, FBQ, FDMQ, FTQ, FCQ, FHQ, FFQ, FXAQ, FXDQ, FXEQ, FXFQ, FXHQ, FXLQ, FXMQ, FXNQ, FXSQ, FXTQ, FXUQ, FXZQ | P1P2 Terminal |
2. Thermostat Wiring
The Daikin ONE+ Smart Thermostat obtains power directly from the adaptor. It is recommended to wire the thermostat wire first, followed by the S21 or P1P2 communication wire. Connect the thermostat terminals (D1, D2, C, R) on the adaptor to the corresponding terminals (1, 2, C, R) on the Daikin ONE+ Thermostat terminal plate using 18AWG 4-conductor non-shielded stranded wire. Ensure termination combinations match the diagram.
Diagram Description: Shows the Thermostat Terminal Plate connecting to the Translation Adaptor's Thermostat Terminal via a Thermostat Wire. The diagram highlights the 'Removable for Easy Installation' feature and labels the terminals on both the adaptor and the plate.
3. S21 Communication Wiring
The S21 Communication terminal is used for S21 indoor units (Single and Multi-splits) only. The included S21 wiring cable uses 2 anchors and the S21/P1P2 wiring slot to route the cable towards the high voltage side of the Adaptor.
The S21 wiring cable connects to the S21 connector on the indoor unit PCB or the S21 connector on the Interface Adaptor, depending on the indoor unit model. Refer to the indoor unit installation manual for locating the S21 connector.
Some single-zone and multi-zone indoor units may not have an S21 connector on the PCB. For these units, an Interface Adaptor must be ordered separately.
Indoor Unit Models | Required Interface Adaptor |
---|---|
FTX09NMVJU, FTX12NMVJU, FTK09NMVJU, FTK12NMVJU, FTX15NMVJU, FTX18NMVJU, FTX24NMVJU, FTK18NMVJU, FTK24NMVJU | KRP067A41E |
KRP980B2E |
Diagram Description: Shows the S21 wiring cable connecting from the S21 Terminal on the adaptor to an S21 Connector on the indoor unit. The diagram also indicates that S21 and Power lights should be on.
4. P1P2 Communication Wiring
The P1P2 Communication terminal is used for P1P2 indoor units only. Use 18-2-non-shielded stranded wire to connect the P1P2 terminal on the Adaptor to the P1P2 terminal of the applicable indoor unit. Do not use the S21 terminal if the P1P2 terminal is used.
Diagram Description: Shows the P1P2 Terminal on the adaptor connecting to the P1P2 Terminal on the indoor unit via a P1P2 wire. The diagram indicates that P1P2 and Power lights should be on.
5. Power Supply
The P1P2 Communication terminal is used for P1P2 indoor units only. Use 18-2-non-shielded stranded wire to connect the P1P2 terminal on the Adaptor to the P1P2 terminal of the applicable indoor unit. Do not use the S21 terminal if P1P2 terminal is used.
Obtain power from indoor unit:
Diagram Description: Shows the Thermostat Terminal Plate connecting to the Translation Adaptor via Thermostat Wire and High-Voltage Power Line. The adaptor also has S21/P1P2 Wiring Slot and Power Indicator. The power line connects to the Indoor Unit Supply Terminal (L1, L2, G).
Obtain power from external power supply:
Diagram Description: Shows the Translation Adaptor connecting via a power cord to an External Power Receptacle.
6. Check Power Indicators
Once wiring and installation are complete, turn on power to the indoor unit. Use the power indicator on the Adaptor to confirm successful wiring. The 'Power' LED indicates power connection. If the indoor unit has S21 termination, the 'S21' LED will be on; if it has P1P2 termination, the 'P1P2' LED will be on. After verifying power and communication, use the rubber grommet to cover the LEDs to prevent light bleeding through the indoor unit.
Diagram Description: Shows LED light status for S21 units with PWR, S21, D1, D2, P1, P2 labels. Also shows LED light status for P1P2 units with PWR, S21, P1, P2 labels.
For some wall-mounted units, the front cover shall be removed to fit inside the piping chase. For other units, put the front cover back onto the translator box and press down until it snaps into place.
CUSTOMER FEEDBACK
Daikin is very interested in all product comments. Please fill out the feedback form on the following link: https://daikincomfort.com/contact-us
You can also scan the QR code on the right to be directed to the feedback page.