Important Safety Information

⚠️ WARNING: HIGH VOLTAGE

Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death.

⚠️ PROP 65 WARNING FOR CALIFORNIA CONSUMERS

Cancer and Reproductive Harm - www.P65Warnings.ca.gov

Safety Precautions

  1. Only qualified personnel can carry out the equipment installation.
  2. Ensure power supply is turned off before starting wiring work and do not turn it on until completion. Refer to the indoor unit installation manual and wiring diagram.
  3. Securely connect all connectors; unsecured connections may lead to improper communication or malfunction.
  4. Do not splice wires.

Items in the Packaging

ItemQuantity
Translation Adaptor with power supply wire1
P1P2 connector (removable)1
Thermostat connector (removable)1
Front cover1
Adaptor mounting plate1
Screws4
Adhesive tape1
Daikin One+ Thermostat1
Thermostat terminal plate1
Thermostat mounting plate1
S21 wiring cable1
Welcome documents1

Product Overview

The Daikin One+ Translation Adaptor connects the Daikin One+ thermostat to Daikin VRV, SkyAir, Single-Zone, and Multi-zone systems. The Daikin One+ Smart Thermostat is not compatible with other wireless or wired remote controllers. For retrofit projects, remove any existing remote controllers before installation.

Dimension Drawings

1. Translation Adaptor

Dimensions: Approximately 213.34mm (width) x 184.49mm (height) x 32.86mm (depth).

2. Mounting Plate

Dimensions: Approximately 180.05mm (width) x 137.00mm (height).

Specification

ModelDTST-ONE-ADA-A
DescriptionDaikin One+ Smart Thermostat for VRV and Ductless Products
Maximum Connections1 S21 Indoor Unit (cannot use with other wireless/wired remote controllers)
16 P1P2 Indoor Units (1 remote controller group) (cannot use with other wireless/wired remote controllers)
Power Wire5.5 ft (included)
Thermostat Wire125 ft (Field-supplied, 18AWG, 4-conductor non-shielded wire)
Max Wiring LengthS21 Communication Wire: 5.5 ft (included)
P1P2 Communication Wire: 6 ft* (Field-supplied, 18AWG, 2-conductor non-shielded stranded wire)
Power SupplyObtained from the Translation Adaptor (110-240 VAC)
DimensionsThermostat: 6.8" x 3.4" x 0.8"
Thermostat Adaptor: 2.72" x 7.26" x 0.43"
WeightThermostat: 10.5 oz
Thermostat Adaptor: 18.4 oz
Storage Temperature32°F to 120°F
Operation TemperatureThermostat: 32°F to 120°F
Thermostat Adaptor: -40°F to 150°F
Humidity20 to 95% RH (non-condensing)

*P1P2 wire has a maximum wiring length of 1640 feet.

Selection of Mounting Location

The recommended mounting location and approach vary for different Daikin indoor unit types.

1. Wall-mounted unit

Applicable models: CTXS, FAQ, FTK_N, FTX_N, FTX_U, FTXG, FTXR, FTXS, FXAQ.

For wall-mounted units, if refrigerant piping is on the right side and the piping chase is not occupied, mount the adaptor inside the indoor unit for concealment. Otherwise, mount it outside.

Mounting outside of the indoor unit: If refrigerant piping is left-side installed and occupies the chase, mount the adaptor outside. Select a location providing access to the indoor unit electrical box while minimizing visibility of the adaptor and wiring.

2. Ducted and Air Handler Unit

Applicable models: CDXS, CXTQ, FBQ, FDMQ, FDXS, FTQ, FXDQ, FXMQ, FXSQ, FXTQ.

Mount the adaptor to the side or top of the indoor unit using adhesive tape, or to a nearby sturdy surface. Ensure access to the indoor unit electrical box.

3. Ceiling Cassette Units

Applicable models: FCQ, FFQ, FXEQ, FXFQ, FXZQ.

Mount the adaptor on top or side of the indoor unit using adhesive tape, or above the ceiling using screws. Ensure access to the indoor unit electrical box.

4. Ceiling suspended Units

Applicable models: FHQ, FXHQ, FXUQ.

Mount the adaptor on top of the indoor unit using adhesive tape (for FXUQ), or above the ceiling. Ensure access to the indoor unit electrical box.

5. Floor-mounted and Floor Standing Units

Applicable models: FVXS, FXLQ, FXMQ, FXNQ.

Mount the translator box by the side of the indoor unit. Select a location that minimizes the view of the adaptor and wiring, while providing access to the indoor unit electrical box.

Mounting

The Translation Adaptor offers two mounting approaches.

1. Mount with two screws

Use the provided screws to mount the adaptor's backplate to a suitable wall surface. Do not mount the adaptor directly to the indoor unit.

[Diagram description: Shows mounting plate, screws, and adaptor being assembled.]

2. Mount with double-sided adhesive tape

Use the provided double-sided adhesive tape to mount the translator box directly onto the indoor unit. The mounting plate has a recess for the tape. Text "APPLY OPTIONAL ADHESIVE STRIP HERE" indicates the tape placement area.

To ensure durable adhesive performance:

[Diagram description: Shows mounting plate with adhesive tape, and adaptor being attached.]

Wiring

1. Overview

The translator box connects the indoor unit and the Daikin One+ Thermostat, powered by the indoor unit or an external source.

For S21 Indoor Units

[Diagram description: Shows wiring from the thermostat terminal plate to the translation adaptor, and then to the S21 connector on the indoor unit or interface adaptor.]

For P1P2 Indoor Units

[Diagram description: Shows wiring from the thermostat terminal plate to the translation adaptor, and then to the P1P2 terminal block on the indoor unit.]

Wiring Requirement Table

Wire NameTypeConnected toMax Length
High-Voltage Power Line3-wire, included in the packageIndoor unit power terminal or external power source5 1/2 ft
Thermostat WireField-supplied, 18 AWG, 4-conductor non-shielded wireDaikin One+ Thermostat125 ft
S21 Communication Wire5-conductor wire with connectors, included in the packageS21 Terminal on the indoor unit PCB or S21 Terminal on the Interface adaptor5.5 ft
P1P2 Communication WireField-supplied, 18 AWG, 2-conductor non-shielded stranded wireP1P2 Terminal on the indoor unit6 ft*

*Max P1P2 wire length is 1640 ft.

Communication Terminal Usage

Only one communication terminal (S21 or P1P2) can be used per indoor unit. Never use both simultaneously.

Indoor Unit Model to Communication Terminal Mapping

Indoor Unit ModelCommunication Terminal
CDXS, CTXS, FDXS, FTK_N, FTX_N, FTX_U, FTXG, FTXR, FTXS, FVXSS21 Terminal
CXTQ, FAQ, FBQ, FDMQ, FTQ, FCQ, FHQ, FFQ, FXAQ, FXDQ, FXEQ, FXFQ, FXHQ, FXLQ, FXMQ, FXNQ, FXSQ, FXTQ, FXUQ, FXZQP1P2 Terminal

2. Thermostat Wiring

The Daikin One+ Smart Thermostat receives power directly from the adaptor. Wire the thermostat wire first, followed by the S21 or P1P2 communication wire. Connect the thermostat terminals (D1, D2, C, R) on the adaptor to the corresponding terminals (1, 2, C, R) on the Daikin One+ Thermostat terminal plate using 18AWG 4-conductor non-shielded wire. Ensure correct termination combinations as shown in the diagram.

[Diagram description: Shows the connection of thermostat wires (D1, D2, C, R) from the adaptor's thermostat terminal to the corresponding terminals on the Daikin One+ Thermostat terminal plate.]

3. S21 Communication Wiring

The S21 communication cable is for S21 indoor units (Single and Multi-splits). Use the provided cable, anchors, and S21/P1P2 wiring slot to route the cable towards the high voltage side of the adaptor.

The S21 wiring cable connects to the S21 connector on the indoor unit PCB or the Interface Adaptor, depending on the indoor unit model. Refer to the indoor unit installation manual for S21 connector location.

Some units may require an Interface Adaptor. The following table lists models requiring an adaptor and its part number.

Indoor Unit Models Requiring Interface Adaptor

Indoor Unit ModelsRequired Interface Adaptor
FTX09NMVJU, FTX12NMVJU, FTK09NMVJU, FTK12NMVJU, FTX15NMVJU, FTX18NMVJU, FTX24NMVJU, FTK18NMVJU, FTK24NMVJUKRP067A41E
KRP980B2E

4. P1P2 Communication Wiring

The P1P2 communication terminal is for P1P2 indoor units only. Use 18-2-non-shielded stranded wire to connect the P1P2 terminal on the adaptor to the P1P2 terminal of the indoor unit. Do not use the S21 terminal if the P1P2 terminal is used.

[Diagram description: Shows the P1P2 communication wire connecting the P1P2 terminal on the adaptor to the P1P2 terminal on the indoor unit.]

5. Power Supply

The P1P2 Communication terminal is used for P1P2 indoor units only. Use 18-2-non-shielded stranded wire to connect the P1P2 terminal on the Adaptor to the P1P2 terminal of the applicable indoor unit. Do not use the S21 terminal if P1P2 terminal is used.

Power can be obtained from the indoor unit or an external power supply.

[Diagram description: Illustrates obtaining power from the indoor unit, showing wiring from the thermostat terminal plate to the translation adaptor, and then to the indoor unit supply terminal (L1, L2, G).]

[Diagram description: Shows an external power supply cord connecting to the translation adaptor.]

6. Check Power Indicators

After wiring and installation are complete, turn on power to the indoor unit. Verify successful wiring using the adaptor's power indicator LEDs.

Once power and communication are verified, use the rubber grommet to cover the LEDs to prevent light bleed-through into the indoor unit.

[Diagram description: Shows the status LEDs on the adaptor for S21 units, labeled PWR, S21, and P1P2.]

[Diagram description: Shows the status LEDs on the adaptor for P1P2 units, labeled PWR, S21, and P1P2.]

For some wall-mounted units, the front cover may need to be removed to fit inside the piping chase. For other units, reattach the front cover by pressing it down until it snaps into place.

Customer Feedback

Daikin values customer feedback. Please fill out the feedback form at https://daikincomfort.com/contact-us. A QR code is also provided for direct access to the feedback page.

[Note: QR code is excluded as per instructions.]

Daikin's commitment to quality may result in specification changes without notice.

© 2020 DAIKIN MANUFACTURING COMPANY, L.P.

19001 Kermier Rd. Waller, TX 77484

www.daikincomfort.com

PDF preview unavailable. Download the PDF instead.

Daikin One Install Manual Adobe PDF Library 15.0 Adobe InDesign 15.1 (Windows)

Related Documents

Preview Daikin One+ Translation Adaptor Installation Instructions
Comprehensive installation guide for the Daikin One+ Translation Adaptor, detailing product overview, specifications, mounting procedures, wiring instructions, and troubleshooting for Daikin HVAC systems.
Preview Daikin ONE+ Translation Adaptor Installation Instructions
This document provides comprehensive installation instructions for the Daikin ONE+ Translation Adaptor, detailing product overview, specifications, safety precautions, mounting procedures for various Daikin indoor units, detailed wiring diagrams for S21 and P1P2 systems, and power indicator checks.
Preview Daikin One+ Smart Thermostat DTST-ONE-ADA-A Submittal Data Sheet
Technical specifications and compatibility information for the Daikin One+ Smart Thermostat (DTST-ONE-ADA-A), designed for VRV, SkyAir, Single-Zone, and Multi-Zone HVAC systems.
Preview Daikin Spring 2024 Single and Multi-Zone System Consumer Rebate Program
Information on the Daikin Spring 2024 consumer rebate program for single and multi-zone HVAC systems, including eligible models and rebate amounts.
Preview Daikin One+ Smart Thermostat for Single & Multi-Zone Systems
Explore the features, compatibility, wiring, and future development of the Daikin One+ Smart Thermostat (DTST-ONE-ADA-A), designed for single and multi-zone HVAC systems, offering advanced control, energy management, and seamless integration.
Preview Daikin AZAI6WSPDKC DKN Plus Interface Submittal Data Sheet
Technical specifications, compatibility, features, system diagrams, and wiring information for the Daikin AZAI6WSPDKC DKN Plus Interface, enabling integration with third-party thermostats and BMS/HAS.
Preview Daikin AZAI6WSPDKC DKN Plus Interface Submittal Data Sheet
Technical specifications, features, compatibility, and system diagrams for the Daikin AZAI6WSPDKC DKN Plus Interface, enabling integration with various HVAC indoor units, smart thermostats, and building management systems.
Preview Daikin Thermostat Limited Warranty Information
Comprehensive warranty details for Daikin thermostats, including models DTST-ONE-ADA-A, DTST-ONE-ADA-B, DTST-LTE-LA-A, DTST-TOU-A, and DTST-TOU-ADA-A. Covers owner-occupied residences, non-owner-occupied residences, and commercial installations, outlining coverage, exclusions, registration, and dispute resolution.