Installation Location Requirements
- Level, water-resistant surface.
- Ambient conditions:
- Maximum humidity: 80%
- Ambient temperature: 10–35 °C
Important Notes
- Connections required on site must be carried out by a qualified professional before JURA's service technician can commission the appliance.
- Ensure connections on site are as close as possible to the appliance's installation location (refer to connection hose lengths).
- The instructions in the operating manual for your fully automatic coffee machine must be followed unconditionally (chapter 'Setting up the appliance').
Dimensions
Front View: The appliance has a width of 373 mm. The overall height is 470 mm.
Side View: The appliance has a depth of 464 mm. The overall height is 470 mm. Specific vertical measurements from the base are 58.4 mm and 119.6 mm. A component height range is indicated as 63–150 mm. A depth measurement is 201 mm.
Overview: Site Requirements and Installation Instructions
This section details site requirements for a fixed water connection, compliant with DVGW W540 standards.
- Network connection point is shown.
- A shut-off valve is required "on site".
- A metal hose (1.5 m) connects to the appliance.
- A waste water hose is also shown.
- A fine filter is recommended before the water connection.
- The connection to the drain pipe should be an "Open, pressureless connection between waste water hose and drain pipe".
- The drain itself is depicted as a "Drain with water trap", also required "on site".
For a detailed installation guide for the fixed water connection, please visit: jura.com/support-X10c.
Appliance Rear View
The rear of the appliance features a G3/8" (plastic) connection.
Measurement points indicated include:
- 18 mm, 76 mm, 22 mm, 84 mm, 204 mm, 243 mm.
Connection points are labeled:
- 1 Drip water hose connection
- 3 Water connection
Placement of Hole in Worktop for Coffee Grounds Ejection
This section outlines the requirements for creating an opening in the worktop for the coffee grounds ejection chute.
- Placement dimensions for the hole are indicated as 193 mm and 180 mm.
- 2 Placement of fitting for coffee grounds ejection is shown.
- The required hole diameter is a minimum of 70 mm.