VEVOR Shower Pump Installation Instructions
Model: FLO300
For technical support and e-warranty, visit: www.vevor.com/support
Product Overview
This document provides installation instructions for the VEVOR FLO300 Shower Pump. It is designed to pump wastewater from showers, sinks, and other sanitary units where gravity drainage is not feasible.
Contact Information: For product questions or technical support, please contact: ✉️ CustomerService@vevor.com
Important Note: Please read all instructions carefully before operating. VEVOR reserves the right to interpret the user manual. Product appearance is subject to the received item. Updates may occur without prior notice.
Kindly Reminder
The FLO300 has been developed with utmost care and tested at the factory. It is possible that residual test water may remain in the appliance upon receipt.
Installation Requirements
This appliance must be earthed.
If the supply cord is damaged, it must be replaced by a qualified person. The cable type is SJT 18AWGx3C. The IP rating of this appliance is IPX4.
The unit is gravity fed from sources like washing machines, showers, etc. It features a built-in pressure switch that detects incoming waste and activates the pump.
The standard outlet connection is 1-1/4" (32 mm), but a 1" (28 mm) connection can be used with a reducer. When connecting pipework, ensure smooth curves to avoid blockages. Avoid 90-degree bends; opt for 45-degree bends instead.
Specifications
Parameter | Value | Parameter | Value |
---|---|---|---|
Input Power Rating | 0.4 HP | Max Vertical Lift | 23 FT |
Input Voltage | 110-120V, 60HZ | Max Temperature | 90°C |
Flow Rated | 1600 GPH | Noise Level | 45 dBA |
Max Horizontal Lift | 230 FT | Degree of Protection | IPX4 |
Water temperature should be a minimum of 1°C to prevent freezing and a maximum of 90°C.
Installation Guidance
Accessories List
- A: Check Valve (X1)
- B: Rubber Tube (X3)
- C: Snap hoop (32mm-50mm) (X3)
- D: Snap hoop (20mm-32mm) (X1)
Step-by-Step Installation
- Install the check valve at the outlet. Tighten with snap hoop (accessory D). Remove the choke plug from the product, install the rubber tube (accessory B), and tighten with snap hoop (accessory C). Outlet pipe can be 3/4", 1", or 1-1/4". Inlet pipes are 1-1/2".
- The product has two water inlets on the other side, covered with choke plugs. When installing, ensure the arrow on the choke plug points downwards, then pull the plug out. Install the snap hoop etc. Unused water inlets should be covered with choke plugs, with the arrow direction turned away.
- Notes and Installation Diagram: For wastewater from showers and baths, ensure the siphon slope is at least 1% (0.4 inches per 40 inches) for gravity flow to the unit. If connecting other sanitary units to the disposal line, install check valves in appropriate waste pipes to prevent backflow. The slope of horizontal components must be at least 1%. Note: Discharge pipe length to the first elbow should be a minimum of 1.6. Installation diagrams demonstrate correct practices including proper inlet/outlet slopes (avoiding horizontal connections), correct pipe bends (preferring 45-degree over 90-degree), secure connections with check valves, and a minimum 6-inch clearance for installations near windows.
- Underground Installation: If installing underground, follow this method. An underground installation diagram shows the pump connected to pipes, emphasizing a 3% downward slope for the wastewater inlet and a minimum 5-inch clearance.
Trouble Shootings
Some malfunctions are minor and can be corrected by the user. Refer to the table below for diagnosis and solutions. For other issues, contact the supplier or a qualified professional.
Malfunctions | Possible Causes | Solutions |
---|---|---|
The appliance occasionally starts to work | The connected pipelines are leaking The check valve is leaking | Check the installation in front of the appliance Clean or replace the check valve |
The motor is running properly, but the water runs slowly away. | The aerator in the lid is blocked | Clean the aerator |
The engine is running properly but non-stop or runs for a long time | The height or length of the drain is too large, or too many bends are used (power failure) | Check the installation |
The pump is blocked | Turn off the power, disassemble the pump and unblock | |
The motor is not switched on | The power supply is not switched on The plug is defective | Switch the power supply on (repeat) Repair the plug |
The motor rattles with a noise | The trouble with the motor or sensor | Remove the lid, flush clean, and dry the sensor (hair dryer) |
The motor is buzzing and does not rotate | There's a strange object in the motor | Remove the lid, clean it and remove the object |
The condensator is broken or has trouble with the motor | Get in contact with a qualified specialist or the supplier | |
There's a strange object in the motor | Remove the lid, clean it and remove the object |
Manufacturer Information
Manufacturer: Ningbo YUNSUN Electromechanical Co., Ltd
Address: Building 3 No.7 Hongshen Road Hongtang Industrial Zone A, Jiangbei District 315033 Zhejiang P.R. China