VEVOR Shower Pump Installation Instructions

Model: FLO300

For technical support and e-warranty, visit: www.vevor.com/support

Product Overview

This document provides installation instructions for the VEVOR FLO300 Shower Pump. It is designed to pump wastewater from showers, sinks, and other sanitary units where gravity drainage is not feasible.

Contact Information: For product questions or technical support, please contact: ✉️ CustomerService@vevor.com

Important Note: Please read all instructions carefully before operating. VEVOR reserves the right to interpret the user manual. Product appearance is subject to the received item. Updates may occur without prior notice.

Kindly Reminder

The FLO300 has been developed with utmost care and tested at the factory. It is possible that residual test water may remain in the appliance upon receipt.

Installation Requirements

This appliance must be earthed.

If the supply cord is damaged, it must be replaced by a qualified person. The cable type is SJT 18AWGx3C. The IP rating of this appliance is IPX4.

The unit is gravity fed from sources like washing machines, showers, etc. It features a built-in pressure switch that detects incoming waste and activates the pump.

The standard outlet connection is 1-1/4" (32 mm), but a 1" (28 mm) connection can be used with a reducer. When connecting pipework, ensure smooth curves to avoid blockages. Avoid 90-degree bends; opt for 45-degree bends instead.

A diagram illustrates the pump's connection to a shower and sink, showing 1-1/2" drains feeding into the pump and a 1" or 1-1/4" discharge pipe.

Specifications

ParameterValueParameterValue
Input Power Rating0.4 HPMax Vertical Lift23 FT
Input Voltage110-120V, 60HZMax Temperature90°C
Flow Rated1600 GPHNoise Level45 dBA
Max Horizontal Lift230 FTDegree of ProtectionIPX4

Water temperature should be a minimum of 1°C to prevent freezing and a maximum of 90°C.

Installation Guidance

Accessories List

Step-by-Step Installation

  1. Install the check valve at the outlet. Tighten with snap hoop (accessory D). Remove the choke plug from the product, install the rubber tube (accessory B), and tighten with snap hoop (accessory C). Outlet pipe can be 3/4", 1", or 1-1/4". Inlet pipes are 1-1/2".
  2. The product has two water inlets on the other side, covered with choke plugs. When installing, ensure the arrow on the choke plug points downwards, then pull the plug out. Install the snap hoop etc. Unused water inlets should be covered with choke plugs, with the arrow direction turned away.
  3. Notes and Installation Diagram: For wastewater from showers and baths, ensure the siphon slope is at least 1% (0.4 inches per 40 inches) for gravity flow to the unit. If connecting other sanitary units to the disposal line, install check valves in appropriate waste pipes to prevent backflow. The slope of horizontal components must be at least 1%. Note: Discharge pipe length to the first elbow should be a minimum of 1.6.
    Installation diagrams demonstrate correct practices including proper inlet/outlet slopes (avoiding horizontal connections), correct pipe bends (preferring 45-degree over 90-degree), secure connections with check valves, and a minimum 6-inch clearance for installations near windows.
  4. Underground Installation: If installing underground, follow this method.
    An underground installation diagram shows the pump connected to pipes, emphasizing a 3% downward slope for the wastewater inlet and a minimum 5-inch clearance.

Trouble Shootings

Some malfunctions are minor and can be corrected by the user. Refer to the table below for diagnosis and solutions. For other issues, contact the supplier or a qualified professional.

MalfunctionsPossible CausesSolutions
The appliance occasionally starts to workThe connected pipelines are leaking
The check valve is leaking
Check the installation in front of the appliance
Clean or replace the check valve
The motor is running properly, but the water runs slowly away.The aerator in the lid is blockedClean the aerator
The engine is running properly but non-stop or runs for a long timeThe height or length of the drain is too large, or too many bends are used (power failure)Check the installation
The pump is blockedTurn off the power, disassemble the pump and unblock
The motor is not switched onThe power supply is not switched on
The plug is defective
Switch the power supply on (repeat)
Repair the plug
The motor rattles with a noiseThe trouble with the motor or sensorRemove the lid, flush clean, and dry the sensor (hair dryer)
The motor is buzzing and does not rotateThere's a strange object in the motorRemove the lid, clean it and remove the object
The condensator is broken or has trouble with the motorGet in contact with a qualified specialist or the supplier
There's a strange object in the motorRemove the lid, clean it and remove the object

Manufacturer Information

Manufacturer: Ningbo YUNSUN Electromechanical Co., Ltd

Address: Building 3 No.7 Hongshen Road Hongtang Industrial Zone A, Jiangbei District 315033 Zhejiang P.R. China

Made In: China

Models: PS300, PS300 Macerator Pump, Macerator Pump, Pump, FLO300

File Info : application/pdf, 12 Pages, 536.91KB

PDF preview unavailable. Download the PDF instead.

PS300说明书(美规) 1679619563343

References

WPS 文字

Related Documents

Preview VEVOR Household Macerating Pump FL0700-C-M Installation Instructions
Comprehensive installation guide for the VEVOR Household Macerating Pump, Model FL0700-C-M. Learn how to properly install, connect, and maintain this powerful and reliable sewage pump for toilets, showers, sinks, and washing machines.
Preview VEVOR FLO300 Shower Pump Installation Instructions
Comprehensive installation guide for the VEVOR FLO300 Shower Pump, detailing requirements, specifications, guidance, and troubleshooting.
Preview VEVOR FLO700 Sewage Pump Installation Instructions and Guide
Comprehensive installation instructions, specifications, warnings, and troubleshooting for the VEVOR FLO700 Sewage Pump. Learn how to properly install and maintain your macerator pump for optimal performance.
Preview VEVOR FLO700 Sewage Pump: Installation Instructions & Guide
Comprehensive installation manual for the VEVOR FLO700 Sewage Pump. Learn how to properly set up your macerator pump with detailed steps, specifications, troubleshooting advice, and safety warnings.
Preview VEVOR FLO700 Sewage Pump Installation Instructions
This guide provides essential installation instructions for the VEVOR FLO700 Sewage Pump. Learn about its specifications, features, and proper setup for residential wastewater management. Includes troubleshooting and support details.
Preview VEVOR FLO900 Macerator Pump User Manual and Installation Guide
Comprehensive user manual for the VEVOR FLO900 Macerator Pump, detailing installation, specifications, troubleshooting, and safety guidelines for indoor use.
Preview VEVOR FLO500 Sewage Pump Installation Instructions
Installation instructions for the VEVOR FLO500 Sewage Pump, including specifications, accessories, functions, installation guidelines, and troubleshooting.
Preview VEVOR RV Macerator Pump Operating Instructions
Comprehensive operating instructions for the VEVOR RV Macerator Pump, Model NMMP12-G120-12-1. Includes features, specifications, product list, wiring diagram, detailed composition, operating instructions, electrical instructions, and troubleshooting.