VEVOR Sewage Pump Installation Instructions
Model: FLO500
VEVOR Tough Tools, Half Price. For Technical Support and E-Warranty Certificate, visit www.vevor.com/support.
This is the original instruction. Please read all manual instructions carefully before operating. VEVOR reserves the right to interpret its user manual. The appearance of the product is subject to the product received. VEVOR will not provide further notice for any technology or software updates on the product.
The FLO500 has been developed with utmost care and tested in the factory. It is possible that test water remains in the appliance.
Accessories
The following accessories are included:
- A-B: Check valve with plastic elbow (1)
- C: Hose Clamp (32-50mm) (4)
- D: Rubber ring to connect the Intelflo toilet and Intelflo pump (1)
- E: Plastic hose (3)
- F: Activated Carbon (1)
- G: Hose Clamp (90-110mm) (1)
- H: Hose Clamp (110-120mm) (1)
- J: Lid (1)
- K: Plug (It Mounted On The Pump) (2)
Specifications
The water temperature should be a minimum of 1°C to prevent freezing, and a maximum water temperature of 90°C.
Parameter | Value | Parameter | Value |
---|---|---|---|
Input Power Rating | 500W | Max Vertical Lift | 8M |
Input Voltage | 220-240V, 50HZ | Max Temperature | 90 °C |
Flow Rated | 110L/MIN | Noise Level | 45 dBA |
Max Horizontal Lift | 80M | Degree of Protection | IPX4 |
How the Unit Functions
The macerator is a tank that is gravity-fed from a toilet, washing machine, shower, etc. It has a built-in pressure switch that detects incoming waste and starts a pump with cutting blades. This process reduces the effluent to a pumpable fluid, which is then pumped through small-diameter pipes into the drains. A non-return valve is fitted as standard, enabling the unit to pump up to 8 meters vertically.
Installation
Electrics
The unit must be installed according to current electrical regulations, with a fused spur mounted outside the room, fused at 3 amps. It is advised that this is done by a registered electrician.
Connection
The unit is designed for a horizontal toilet with an outlet 18 cm from the floor (standard European). All other inlets must be gravity-fed into the unit. The outlet comes standard with a 32 mm connection, but a 22 mm connection can be used with a reducer. It is important that the pipe run uses radius bends and avoids 90-degree (right-angle) elbows to prevent blockages.
Visual Description: Two diagrams are shown. The first shows a correct installation with a green checkmark, indicating a curved pipe bend. The second shows an incorrect installation with a red cross, indicating a sharp 90-degree elbow.
If the water outlet is discharged horizontally, the water pipe must have a 1% inclination.
If the sewage is discharged upwards, the horizontal pipe should not exceed 1 ft (30 cm).
Inlet
The unit can be used with one input, such as a toilet, shower, or sink, or multiple inputs simultaneously. Blanking covers are provided for unused inlets.
Warnings
-
Electrical Installation:
The connection must be carried out by a qualified technician, adhering to electrical installation rules (NEN 1010). If the power cord is damaged, it must be replaced by the manufacturer or supplier to avoid danger. The appliance connection is Class 1. Connect the appliance to a socket with a protective conductor connection.
-
Thermal Protection:
This appliance is equipped with thermal protection that switches off the power supply for 2 hours after overheating. Power on the electrical connection only when the appliance is fully installed. In case of prolonged absence (e.g., vacation), close the water supply to the appliance. Do not expose the appliance to temperatures below 0°C or above 50°C.
-
If the indications are not followed, it could cause personal security risks.
-
Wrong Use:
Use only for human excrement and soluble toilet paper. Equipment damage due to improper use is not covered by the warranty. Examples of damage from improper use include grinding cotton wool, tampons, sanitary napkins, panty liners, food, condoms, towels, hair, rinsing liquids, and solvents or oils.
Trouble Shootings
Some malfunctions of the grinder are not serious and can be corrected by the user. Refer to the table below for diagnosis and solutions. For other malfunctions, contact the supplier or a qualified professional.
Malfunctions | Possible Causes | Solutions |
---|---|---|
The appliance occasionally starts to work | The connected pipelines are leaking The check valve is leaking |
Check the installation in front of the appliance Clean or replace the check valve |
The motor is running properly, but the water runs slowly away. | The aerator in the lid is blocked | Clean the aerator |
The engine is running properly but non-stop or runs for a long time | The height or length of the drain is too large, or too many bends are used (power failure) The pump is blocked |
Check the installation Turn off the power, disassemble the pump and unblock |
The motor is not switched on | The power supply is not switched on The plug is defective The trouble with the motor or sensor |
Switch the on power supply (repeat) Repair the plug Remove the lid, flush clean, and dry the sensor (hair dryer) |
The motor rattles with a noise | There's a strange object in the motor | Remove the lid, clean it and remove the object |
The motor is buzzing and does not rotate | The condensator is broken or has trouble with the motor There's a strange object in the motor |
Get in contact with a qualified specialist or the supplier Remove the lid, clean it and remove the object |
Company Information
Importer: WAITCHX
Address: 250 bis boulevard Saint-Germain 75007 Paris
Importer: FREE MOOD LTD
Address: 2 Holywell Lane, London, England, EC2A 3ET
Manufacturer: Ningbo YUNSUN Electromechanical Co., Ltd
Address: Building 3 No.7 Hongshen Road Hongtang Industrial Zone A, Jiangbei District 315033 Zhejiang P.R. China
Made In China
European Representatives:
UK REP: EUREP UK LTD
Address: UNIT 2264, 100 OCK STREET, ABINGDON, OXFORDSHIRE ENGLAND OX14 5DH
EC REP: EUREP GmbH
Address: Unterlettenweg 1a, 85051 Ingolstadt, Germany