FEATURES
- Connects directly to the RV waste outlet
- Ability to dump longer distances
- Garden hose discharge port
- Ability to drain holding tanks at home
- Fresh water rinse capabilities
- Easy clean up and storage
SPECIFICATIONS
Pump: Self-Priming Flexible Impeller with Stainless Steel Wear plate.
Macerator: Stainless Steel Cutter reduces particle size to 1/8" (4 mm) maximum.
Seal: Lip Type
Ports: Inlet - 3" (75 mm) RV Connector; Outlet - 1" hose barb.
Motor: 12 Vdc Permanent Magnet Type, Fully Enclosed, with Stainless Steel Shaft Intermittent Duty Only.
Model | NMMP12-G120-12-1 |
Size | 295.5*148.2*132.7 mm |
Rated Voltage | DC12V |
Max Flow | 12 GPM |
Max lift | ≥ 10 ft |
Power cord length | 7 ft |
PRODUCT LIST
Description | Quantity |
Rv Macerator Pump | 1 |
Detachable quick connection valve with switch | 1 |
Metal hose clamp | 2 |
1 inch clear hose | 1 |
1inch+3/4inch NPT Copper joint | 1 |
7 ft Power cord | 1 |
Operating Instruction | 1 |
WARNING
The NMMP12-G120 DC waste pump is the ideal solution for emptying holding tanks on recreational vehicles and avoiding dump stations. Empties a typical 40-gallon holding tank in less than 5 minutes. Do not run for more than.
WARNING
- DO NOT RUN DRY FOR MORE THAN 30 SECONDS.
- DO NOT MOUNT PERMANENTLY TO THE RV WASTE PORT.
WIRING DIAGRAM
A diagram shows the wiring connections for the RV Macerator Pump. It illustrates the connection of the water inlet (garden hose connection) and discharge port (garden hose connection) to the pump. The wiring includes a red (+) wire and a black (-) wire connecting to an ON/OFF switch, which then connects to a car adapter. The red (+) wire from the pump connects to the switch, and the black (-) wire from the pump also connects to the switch.
DETAILED COMPOSITION
A diagram illustrates the detailed components of the RV Macerator Pump. The components are numbered and correspond to a list:
Key | Description | Key | Description |
1 | Screw | 12 | Impeller housing |
2 | Pump head gasket | 13 | Outlet Cover |
3 | Pump head | 14 | Oil seal |
4 | Pump head check valve | 15 | Seal |
5 | gasket | 16 | Motor |
6 | Resin connector | 17 | Rubber Feet |
7 | Screw Nut | 18 | Iron Plate |
8 | Blade | 19 | Screw |
9 | Round stainless steel sheet | 20 | Adjustment Cap O-ring |
10 | Impeller | 21 | Adjustment Cap |
11 | Convex stainless steel sheet |
OPERATING INSTRUCTIONS
- Remove the end cap from the drain pipe.
- Install the waste pump on the drain in any convenient position, twisting clockwise to lock.
- Be sure that the o-ring is on the pump adapter prior to installing the unit.
- Install waste/garden hose on the discharge port adapter.
- Install the rinse water hose to the on-off valve.
- Open the black water valve, and turn on the pump.
- Turn off the pump and open the gray water valve. Let gray water back flush the black water tank. Turn on the pump.
- Turn off the pump, open the rinsing valve, and backfill tanks for rinsing. Turn on the pump. Turn off the rinse water. Drain tanks.
- Close both drain valves, and turn on the rinse water (40 PSI max.) and pump. Rinse the pump and discharge hose.
- Turn off the water and pump, and disconnect the hose and pump.
- Store until next use.
- Replace the end cap on the drain pipe.
ELECTRICAL INSTRUCTIONS
- Refer to electrical drawing below. Connect the switch assembly to RV waste pump motor wires with butt connectors (connect the red motor wire to the red switch wire; and the black motor wire to the black switch wire).
- Connect the car adaptor to the power.
- Fuse Replacement: The fuse is inside the car adaptor. Use an automotive 20 amp fuse for replacement.
Wire Size Recommendations for 12 Volt System
Total Wire Length* Feet [m] | Min. Wire Size (20 Amps) | |
3% Drop | 10% Drop | |
1-10 [.^3] | #10 GA | #16 GA |
11-20 [3.3-6] | #8 GA | #14 GA |
21-30 [6.4-9.1] | #6 GA | #12 GA |
31-60 [9.1-18.2] | #4 GA | #10 GA |
*length from the power source to the motor and back to the ground.
ELECTRICAL INSTRUCTIONS
TURN OFF ALL POWER!
-REAR END CAP/MOTOR SHAFT ACCESS
Loosen the shaft knob (21), and put the D-type rotary knob mounted on one end of the rear end of the motor.
-PUMP DISASSEMBLY
Remove 4 cover screws (1). Remove cutter housing (3) and gasket (5). It is necessary to hold the motor shaft steady. Remove the hex nut (7) and cutter blades (8). Insert a screwdriver into the slot on the motor shaft (see slot access above), or slip a thin wrench (9/32"[7mm]) behind the blades onto the flat of the motor shaft. Remove hex nut (7) and cutter (8). Remove the top wear plate (9), gasket (5), impeller (10), and bottom wear plate (11). Remove the impeller housing (12) and shaft seal (14). It is not necessary to remove the slinger (15).
-PUMP ASSEMBLY
Ensure the slinger (15) is on the motor shaft. Ensure that the shaft seal (14) can be inserted into the right position of the impeller housing (12). Install the impeller housing (12) to the motor shaft. Install the bottom wear plate (11) insert to the impeller housing (11). Rotate the impeller (9) to the impeller housing (12) counterclockwise. Install the gasket (5) and top wear plate (9). Install the cutter blade (8) and align it with the motor shaft. Fixing the motor shaft with a screwdriver or a wrench(9/32H[7mm]) to tighten the hex nut (7). Installed gasket (5) and cutter housing (3) and tightened the screw (1).
DANGER
Do NOT use the pump if any part of the housing switch or probe is cracked, broken, or missing.
Always disconnect the electric supply before attempting to install, service, relocate, or perform any maintenance. If the power source is out of sight, lock and tag in the open (off) position to prevent unexpected power application. Failure to do so WILL result in fatal electrical shock!
TROUBLESHOOTING
Please turn off the power before checking the fault.
Problem | Possible Cause | Corrective Action |
The pump won't start or run | 1. Blown fuse 2. Defective motor 3. You are connected to the wrong line. | 1. If blown, replace with fuse of proper size. 2. Replace the pump. 3.Connect the circuit correctly according to the instruction circuit diagram. |
The pump operates but delivers little or no water | 1. Something stuck in the blade. 2. The hose doesn't fit the machine. | 1.Remove residue from the blades. The blade is sharp. Please be careful of cuts. 2. Use the correct hose. |
Pump is blocked | Something hard jammed the blade. | Power off, open the knob at the end of the motor in the counterclockwise direction and then rotating the bolt clockwise with a screwdriver to loosen the blade. |
*There are any minor changes to the numbers included in the user manual without prior notice.
Made In China
Related Documents
![]() | VEVOR Household Macerating Pump FL0700-C-M Installation Instructions Comprehensive installation guide for the VEVOR Household Macerating Pump, Model FL0700-C-M. Learn how to properly install, connect, and maintain this powerful and reliable sewage pump for toilets, showers, sinks, and washing machines. |
![]() | VEVOR FLO500 Sewage Pump Installation Instructions Installation instructions for the VEVOR FLO500 Sewage Pump, including specifications, accessories, functions, installation guidelines, and troubleshooting. |
![]() | VEVOR NMDP52-G55-70-12 Diaphragm Pump Instruction Manual | Installation & Troubleshooting Comprehensive instruction manual for the VEVOR NMDP52-G55-70-12 12V DC Diaphragm Pump. Covers specifications, features, applications, installation, troubleshooting, and adjustments for this 5.5 GPM, 70 PSI heavy-duty water pump. |
![]() | VEVOR FLO700 Sewage Pump Installation Instructions This guide provides essential installation instructions for the VEVOR FLO700 Sewage Pump. Learn about its specifications, features, and proper setup for residential wastewater management. Includes troubleshooting and support details. |
![]() | VEVOR FLO900 Macerator Pump User Manual and Installation Guide Comprehensive user manual for the VEVOR FLO900 Macerator Pump, detailing installation, specifications, troubleshooting, and safety guidelines for indoor use. |
![]() | VEVOR FLO500-DE Pro Macerator Pump User Manual & Technical Guide Comprehensive user manual for the VEVOR FLO500-DE Pro Macerator Pump, covering specifications, installation, operation, troubleshooting, and safety guidelines. Visit www.vevor.com/support for technical assistance. |
![]() | VEVOR FLO700 Sewage Pump Installation Instructions and Guide Comprehensive installation instructions, specifications, warnings, and troubleshooting for the VEVOR FLO700 Sewage Pump. Learn how to properly install and maintain your macerator pump for optimal performance. |
![]() | VEVOR FLO500 Sewage Pump Installation Instructions Comprehensive installation guide for the VEVOR FLO500 Sewage Pump, detailing setup, specifications, functions, warnings, and troubleshooting for effective wastewater management. |