Ecotap DC60 Charging Station Specifications
Ecotap B.V., a brand of Legrand
General Features
Reference Number | 80060008 / 80080035 / 80080328 / 80080135 / 80082435 / 80080235 / 80082011 / 80082335 |
Accessory | 331007 |
Dimensions (H x W x D) | 1440 mm x 610 mm x 350 mm |
Enclosure Material | Steel 2.2 mm |
Standard Color | Body: Ral 9016 / Shield: Ral 9016 |
Steel Treatment | Anti-corrosion (KTL) and powder coating |
Weight (kg) | 235 kg |
Number of Charging Points | 1 for 80060008 / 80080035 / 80080328 / 80080135 2 for 80082435 / 80080235 / 80082011 / 80082335 |
Cable | CCS2 |
Electrical Characteristics
AC Input Voltage | 3 x 400VAC + N ± 10% |
AC Input Current and Power (line) | 90A at 60 kW DC output power |
AC Input Frequency (fn) | 50Hz |
DC Output Power Range | 1 - 60 kW |
DC Output Voltage | 200 - 1000 Vdc |
DC Output Current Range | 1xCCS: 0 - 200A 2xCCS: 0 - 100A (2xCCS use), 0 - 200A (1xCCS use) |
DC Output Voltage Stabilized Accuracy | ≤ ±0.5% |
DC Output Current Stabilized Accuracy | ≤ ±1% |
Efficiency | > 95% @full load |
THDi (Total Harmonic Distortion) | < 5% (load 50% to 100%) |
Power Factor | > 0.99 (load 100%); > 0.98 (load 50% to 100%) |
Mains Type | TN-C, TN-S, TN-C-S or TT |
Impulse Voltage (Uimp) | 4kV |
Insulation Voltage (Ui) | 230V single-phase 500V three-phase |
Integrated Safety System | Fuse 125A gG + Each PSU MCB 63A Curve C & RCD 63A Type B |
Conditional Short-Circuit Current | 6000A IEC/EN 60898-1 10kA IEC/EN 60947-2 |
Admissible Thermal Current during Short Circuit | 16 000 A²s |
Integrated Surge Protection | Not included |
Stand-by Consumption (W) | < 40W |
Connection to Mains | Phases, Earth, cable lug terminals M8 |
Tightening Torque | 22-36 N.m for M8 |
Load Type | Mode 4 charging terminal |
Vehicle Connection Mode 4 Cable Connection | Use of extension and adapter prohibited. 8m straight 200A CCS2 |
AC Meter | Not included |
DC Meter | 80060008 / 80080035 / 80082435 / 80080235: Not included 80080328 / 80080135 / 80082011 / 80082335: included |
Backoffice Protocol | OCPP 1.6 Json |
Positioning | GPS |
Ethernet Connectivity | RJ45 connection |
Payment Terminal | Can be integrated in all models. List of available payment terminals: - Apollo Payment Terminal - Worldline VALINA Payment Terminal - PAX IM30 Payment Terminal |
Environment
Operating Temperature | -25°C / +50°C |
Storage Temperature | -25°C / +80°C |
Relative Humidity | 0 to 90% without condensation |
Corrosion Class | C4 according to IEC 9223 and IEC 12944 3C3/4C3 according to IEC 60721-3 |
Protection | IP 54 (IEC 60529), IK 10 (EN 62262) whether connected or not |
Vandalism Resistance | IK 10 |
Noise Level | < 72 dB at 1m at 20° C, at full charge |
Product Standards | IEC 61851-1, IEC TS 61439-7 (AEVCS), IEC 61851-23, IEC 62477-1, IEC 61439-1 |
DC Standard Protocol (vehicle communication) | CCS2: IEC 61851-23 / DIN SPEC 70121 CHAdeMO: CHAdeMO 1.2 |
Installation | Indoor or outdoor, restricted access area, intended for use by ordinary persons (DBO), cabinet installation (wall mounting), pollution degree 3, TN-C, TN-S, TN-C-S or TT compatible earthing system. In case of an IT earthing system, this can be locally modified by adding an isolation transformer. |
Electrical Safety | Class 1 IEC 61140 |
Metrological Approval | No |
Electromagnetic Compatibility
European Standards | Low Voltage Directive 2014 / 35EU / EMC Directive: 2014 / 30 / EU |
Radio Technology Type | GSM 2G/3G/4G, GPRS, RFID |
Suitable Charging Cards | Mifare, Ntag and iCODE SLI cards |