XBA-RUB8 Bill Acceptor Configuration and Settings
XBA Option Switch Settings (Pulse/MDB/ICT104U/ICT104V)
Supported bill denominations: RUB 10, 50, 100, 200, 500, 1000, 2000, 5000.
FUNCTION | SW1 | SW2 | SW3 | SW4 | SW5 | SW6 | SW7 | SW8 |
---|---|---|---|---|---|---|---|---|
Inhibit Active HIGH | ON | |||||||
Inhibit Active LOW | OFF | |||||||
• Reject RUB 10 (Note.2) | ON | |||||||
Accept RUB 10 (Note.2) | OFF | |||||||
• Reject RUB 50 & 100 & 200 | ON | |||||||
Accept RUB 50 & 100 & 200 | OFF | |||||||
• Reject RUB 500 & 1000 | ON | |||||||
Accept RUB 500 & 1000 | OFF | |||||||
• Reject RUB 2000 | ON | |||||||
Accept RUB 2000 | OFF | |||||||
• Reject RUB 5000 | ON | |||||||
Accept RUB 5000 | OFF | |||||||
Disable Bill Reject 4 Times BA Stop By 30 Sec | ON | |||||||
Enable Bill Reject 4 Times BA Stop By 30 Sec | OFF | |||||||
Stack Banknote when Power-up | ON | |||||||
Reject Banknote when Power-up | OFF | |||||||
Reserved | ON | |||||||
Reserved | OFF |
This dip switch is located at the side of XBA.
Diagram: Visual representation of the side of the XBA unit, highlighting the location of the DIP Switch.
Currency Assign Data
Interface | Bill value | MDB | ICT104U | ICT104V | Pulse |
---|---|---|---|---|---|
SW1 Dip1 | BV1 | RUB 10 | RUB 10 | RUB 10 | RUB 50 |
BV2 | RUB 50 | RUB 50 | RUB 50 | RUB 100 | |
BV3 | RUB 100 | RUB 100 | RUB 100 | RUB 500 | |
BV4 | RUB 500 | RUB 500 | RUB 500 | RUB 1000 | |
BV5 | RUB 1000 | RUB 1000 | RUB 1000 | RUB 5000 | |
BV6 | RUB 5000 | RUB 5000 | RUB 5000 | RUB 200 | |
BV7 | RUB 200 | RUB 200 | RUB 200 | RUB 2000 | |
BV8 | RUB 2000 | RUB 2000 | RUB 2000 | RUB 2000 |
XBA-RUB8 (Pulse/MDB/ICT104U/ICT104V) - Additional Settings
FUNCTION | SW1 | SW2 | SW3 | SW4 | SW5 | SW6 | SW7 | SW8 |
---|---|---|---|---|---|---|---|---|
Inhibit Active HIGH | ON | |||||||
Inhibit Active LOW | OFF | |||||||
Reserved | ON | |||||||
Reserved | OFF | |||||||
Reserved | ON | |||||||
Reserved | OFF | |||||||
Reserved | ON | |||||||
Reserved | OFF | |||||||
Pulse Mode | MDB Mode | ICT104V Mode | ||||||
Credit-Pulse Normal LOW | Scaling Factor (SF) = 100 Decimal Point Position (DPP) = 2 |
Connect with coin changer | ||||||
Credit-Pulse Normal HIGH | Scaling Factor (SF) = 1 Decimal Point Position (DPP) = 0 |
Connect with ICT JPSTD converter board |
||||||
Pulse Mode | Other Mode | ICT104V Mode | ||||||
VDB Mode | ON | |||||||
Reserved | OFF | |||||||
ICT104U Mode | ON | |||||||
ICT104V Mode | OFF | |||||||
Pulse Mode | Other Mode | ICT104V Mode | ||||||
VDB Mode | OFF OFF | |||||||
Reserved | OFF ON | |||||||
ICT104U Mode | ON OFF | |||||||
ICT104V Mode | ON ON |
This dip switch is located on the CPU board; remove the CPU board cover first.
Diagram: Visual representation of the CPU board with a callout pointing to the DIP Switch (labeled as (1)).
Operational Notes
• Manufacturer setting
After setting the dip switch for credit pulses, you should reset the bill acceptor again.
Note:
- Calibration card is needed.
- Pulse Mode: When Dip 1 is OFF, One Pulse per RUB 10.
- Pulse Mode: When Dip 1 is ON, One Pulse per RUB 50.