Lennox Submittal Data: MMDD018S6-1P (CNG18LDD) Medium Static Ducted Unit
Powered by SAMSUNG
General Information
The system provides high heating capacity at -4°F (-20°C), with heating operation down to -13°F (-25°C).
- The outdoor unit features a standard base pan heater for optimal defrost cycle water drainage.
- The indoor unit includes an integral condensate pump with a maximum 29" lift from the bottom of the unit. It has a check valve and float switch that disables the indoor unit in case of condensate overflow.
- Comfort humidity control is achieved through an integral humidity sensor, optimizing indoor unit coil temperature based on dew point for enhanced dehumidification and occupant comfort.
- A built-in Wi-Fi adapter is standard for control and monitoring via the Samsung SmartThings app.
- Features auto-restart after power loss.
- Includes soft-start compressor to minimize current inrush.
- The outdoor unit supplies 208/230V power to the indoor unit via a 14 AWG x 3 interconnect power cable.
Construction
- Outdoor unit: Galvanized steel with a durable, baked-on powder coated finish.
- Indoor unit: Insulated, galvanized steel.
- All heat exchangers utilize mechanically bonded aluminum fin to copper tube construction.
- The outdoor unit supplies power to the indoor unit via 14 AWG x 3 power wire.
Refrigerant System
- Utilizes low-GWP R-32 refrigerant.
- Refrigerant flow is controlled by an electronic expansion valve located at the outdoor unit.
- Includes an R32 alarm output plug on both the indoor and outdoor units for notification of R32 leak detection when the optional refrigerant leak detector is installed and configured (requires leak detector and VSTAT10P-1 accessory).
Indoor Fan
- Offers three fan speeds and an auto setting.
Controls
- Control wiring uses 2 x 16 AWG wire.
- No additional interface modules or adapters are required for connection to Samsung central control options.
- The unit can be operated via a wireless or wired remote control with a DDC type signal.
- Supports dual set temperature when connected to supported controllers.
- Wired or wireless controllers must be purchased separately.
External Heat Control
- External heat control functionality allows configuration of fan operation during auxiliary heat, defrost, and emergency heat modes (requires VSTAT10P-1 accessory).
- Configuration settings include: outside ambient external heat lockout, outside ambient compressor lockout, and time delay options (requires VSTAT10P-1 accessory).
- Emergency heat functionality enables the system to continue controlling the external heat source even if system errors prevent the heat pump from operating (requires VSTAT10P-1 accessory).
Convenience
- Outdoor unit includes a snow accumulation prevention option to prevent snow drifting against an idle outdoor unit.
- Night-time Quiet Mode reduces operational sound during evening hours, with automatic or manual activation.
- Emergency Temperature Output (ETO) function: signals an external source (e.g., backup system, building management system, alert device) if the indoor unit is in an error status or if room temperature exceeds a configurable level.
- The system can be configured for heating/cooling, cooling only, or heating only via outdoor unit option settings.
- Maximum Current Control is configurable from 50% to 100% via the outdoor unit, wired controller, or central control.
Specifications
Model | US Code: CNG18LDD | Model Number: MMDD018S6-1P |
Performance | Nominal Capacity: Cooling (Btu/h): 17,500 Heating (Btu/h): 20,000 |
Voltage: 1/208-230/60 Hz |
Power | Operating Current (max.): Cooling (A): 1.06 Heating (A): 1.06 |
Type: BLDC (1) With Sirocco Fan (2) |
Evaporator Fan | Consumption: Watts: 84 External Static Pressure: Standard ("WC): 0.10 Min. / Max. ("WC): 0.01 / 0.24 |
|
Airflow | Air Volume (L/M/H/Turbo): Cooling (CFM): 353 / 459 / 601 Heating (CFM): 353 / 459 / 601 |
|
Refrigerant | Type: R-32 A2L Leak Detection: Optional Accessory |
|
Pipe Connections | Indoor & Outdoor: High side: 1/4 Low side: 1/2 |
|
Dimensions | Condensate Connection: 1 1/4 in. OD, 1 in. ID W x H x D: 43 5/16 x 7 13/16 x 17 5/16 in. Weight: 49.60 lbs. Duct Connections (W x H): Supply (in.): 37 1/16 x 5 7/8 Return (ID, in.): 38 1/2 x 6 5/8 (inside) |
|
Operating Temperatures | Indoor: Cooling: 64~90°F (16~32°C) Heating: T ≤ 86°F (30°C) |
|
Sound Pressure Level | Low / Med. / High: 28 / 32 / 35 dB(A) | |
Safety | Certifications: UL 60335-2-40 |
Accessories
- R32 Refrigerant leak detector (RDS): M1LRDS01
- Wired controller: Advanced: VSTAT04P-1, Touchscreen: VSTAT02P-1
- Thermostat adapter (for connection to standard 24VAC thermostats): VSTAT09P-1
- Wireless signal receiver: VCTRL10P-1
- Wireless signal control: Wireless controller: VSTAT01P-1
- External temperature sensor: VCTRL11P-1
- External contact control interface module: VSTAT10P-1
- Filter box: V1FBX06-4P
Dimensional Drawing
The unit dimensions are provided in inches. Key connection points and air inlet/outlet dimensions are detailed.
Key Connections:
- 1: Liquid pipe connection
- 2: Gas pipe connection
- 3: Gravity drain connection
- 4: Drain connection
- 5: Opening for power and communication wire conduit
- 6: Supply air outlet flange
- 7: Return air (air inlet)
- 8: Suspension bolt anchor point
Diagrams show overall unit dimensions, air inlet/outlet sizes, and pipe connection locations. Specific measurements are provided for each component.