Product Data Sheet: Altivar Process ATV630D11Y6
Main Specifications
Attribute | Value |
---|---|
Range of Product | Altivar Process ATV600 |
Product Specific Application | Process and utilities |
Product or Component Type | Variable speed drive |
Variant | Standard version |
Device short name | ATV630 |
Mounting Mode | Wall mount |
Communication Port Protocol | Ethernet, Modbus serial, Modbus TCP |
[Us] rated supply voltage | 500...690 V - 15...10% |
Relative symmetric mains voltage tolerance | 10% |
Relative symmetric network frequency tolerance | 5% |
Nominal output current | 13.5 A |
IP degree of protection | IP21 (with optional kit) |
Product destination | Asynchronous motors, Synchronous motors |
EMC filter | Integrated 82.02 ft (25 m) IEC 61800-3 category C3 |
IP degree of protection | IP00 (IEC 61800-5-1), IP00 (IEC 60529), IP20 with kit VW3A9705 (IEC 61800-5-1), IP20 with kit VW3A9705 (IEC 60529) |
Type of cooling | Forced convection |
Supply frequency | 50...60 Hz - 5...5% |
Motor power kW | 7.5 kW (500 V normal duty), 5.5 kW (500 V heavy duty), 11 kW (690 V normal duty), 7.5 kW (690 V heavy duty) |
Maximum Horse Power Rating | 10 hp (500 V normal duty), 7.5 hp (500 V heavy duty), 15 hp (690 V normal duty), 10 hp (690 V heavy duty) |
Line current | 13.6 A (500 V normal duty), 14.7 A (690 V normal duty), 10.4 A (500 V heavy duty), 10.5 A (690 V heavy duty) |
Continuous output current | 13.5 A (4 kHz normal duty), 9.5 A (4 kHz heavy duty) |
Complementary Specifications
Attribute | Value |
---|---|
Speed drive output frequency | 0.1...500 Hz |
Safety function | STO (safe torque off) SIL 3 |
Option card | Slot A communication module (Profibus DP V1, PROFINET, DeviceNet, Modbus TCP/EtherNet/IP, CANopen, Ethernet IP/Modbus TCP/MD-Link, BACnet MS/TP, Ethernet Powerlink), Slot A/slot B digital and analog I/O extension module, Slot A/slot B output relay extension module |
Discrete input number | 8 |
Discrete input type | DI1...DI8 programmable as pulse input (0...30 kHz, 24 V DC <= 30 V) |
Discrete input logic | 16 preset speeds, Positive logic (source), Negative logic (sink) |
Discrete output number | 0 |
Discrete output type | Relay outputs R1A, R1B, R1C (250 V AC 3000 mA, 30 V DC 3000 mA), Relay outputs R2A, R2C (250 V AC 5000 mA, 30 V DC 5000 mA), Relay outputs R3A, R3C (250 V AC 5000 mA, 30 V DC 5000 mA) |
Analogue input number | 3 |
Analogue input type | Al1, Al2, Al3 software-configurable voltage (0...10 V DC, -10...10 V DC) or current (0...20 mA) |
Analogue output number | 2 |
Analogue output type | Software-configurable voltage (0...10 V DC) or current (0...20 mA), Software-configurable current DQ-, DQ+ (30 V DC, 100 mA) |
Relay output number | 3 |
Relay output type | Configurable relay logic R1 fault relay (NO/NC 100000 cycles), Configurable relay logic R2 sequence relay (NO 100000 cycles), Configurable relay logic R3 sequence relay (NO 100000 cycles) |
Maximum switching current | 3 A (250 V AC, 30 V DC resistive, cos phi = 1), 2 A (250 V AC, 30 V DC inductive, cos phi = 0.4, 7 ms) |
Minimum switching current | 5 mA (24 V DC) |
Phase | 3 phase |
Physical interface | Ethernet, 2-wire RS 485 |
Method of access | Slave Modbus TCP |
Transmission Rate | 10, 100 Mbits |
Transmission frame | 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps |
Output voltage | <= power supply voltage |
Permissible temporary current boost | 1.1 x In (60 s normal duty), 1.5 x In (60 s heavy duty) |
Data format | 8 bits, configurable odd, even or no parity |
Electrical Connection and Characteristics
Attribute | Value |
---|---|
Type of polarization | No impedance |
Frequency resolution | Display unit 0.1 Hz, Analog input 0.012/50 Hz |
Electrical connection | Control removable screw terminals (0.5...1.5 mm² AWG 20...AWG 16), Motor screw terminal (4...10 mm² AWG 12...AWG 8), Line side screw terminal (4...10 mm² AWG 12...AWG 8) |
Connector type | RJ45 on the remote graphic terminal (Ethernet/Modbus TCP, Modbus serial) |
Exchange mode | Half duplex, full duplex, autonegotiation (Ethernet/Modbus TCP) |
Number of addresses | 1...247 (Modbus serial) |
Supply | External supply for digital inputs (24 V DC, 19...30 V), <1.25 mA overload/short-circuit protection; Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5%, <10 mA overload/short-circuit protection; Internal supply for digital inputs and STO (24 V DC, 21...27 V), <200 mA overload/short-circuit protection |
Local signalling | 3 LEDs for local diagnostic, 3 LEDs (dual colour) for embedded communication status, 4 LEDs (dual colour) for communication module status, 1 LED (red) for presence of voltage |
Input compatibility | DI1...DI6 discrete input level 1 (PLC IEC 61131-2), DI5, DI6 discrete input level 1 (PLC IEC 65A-68), STOA, STOB discrete input level 1 (PLC IEC 61131-2) |
Discrete input logic | Positive logic (source) DI1...DI8 (< 5 V, > 11 V), Negative logic (sink) DI1...DI8 (> 16 V, < 10 V) |
Sampling duration | 2 ms +/- 0.5 ms (DI1...DI4), 5 ms +/- 1 ms (DI5, DI6), 5 ms +/- 0.1 ms (Al1, Al2, Al3), 10 ms +/- 1 ms (AO1) |
Accuracy | +/- 0.6% (Al1, Al2, Al3) for temperature variation 60 °C, +/-1% (AO1, AO2) for temperature variation 60 °C |
Linearity error | Al1, Al2, Al3 +/- 0.15% of maximum value, AO1, AO2 +/- 0.2% |
Refresh time | Relay output R1, R2, R3: 5 ms +/- 0.5 ms |
Isolation | Between power and control terminals |
Enclosure mounting | Wall mounted |
4 quadrant operation possible | False |
Asynchronous Motor Control Profile
- Optimized torque mode
- Constant torque standard
- Variable torque standard
Synchronous Motor Control Profile
- Permanent magnet motor
- Synchronous reluctance motor
Attribute | Value |
---|---|
Maximum output frequency | 500 kHz |
Acceleration and deceleration ramps | S, U or customized, Linear adjustable separately from 0.01...9999 s |
Motor slip compensation | Not available in permanent magnet motor law, Automatic whatever the load, Adjustable, Can be suppressed |
Switching frequency | 2...8 kHz adjustable, 4...8 kHz with derating factor |
Nominal switching frequency | 4 kHz |
Braking to standstill | By DC injection |
Brake chopper integrated | False |
Input and Output Current
Attribute | Value |
---|---|
Maximum Input Current per Phase | 14.7 A |
Maximum output voltage | 690.0 V |
Apparent power | 17.6 kVA (690 V normal duty), 12.5 kVA (690 V heavy duty) |
Maximum transient current | 14.9 A (60 s normal duty), 14.3 A (60 s heavy duty) |
Network Frequency | 50-60 Hz |
Prospective line Isc | 70 kA |
Base load current at high overload | 9.5 A |
Base load current at low overload | 13.5 A |
Power dissipation in W | Natural convection 98 W (500 V, 4 kHz), Forced convection 198 W (500 V, 4 kHz) |
Safety Functions
- With safety function Safely Limited Speed (SLS): False
- With safety function Safe brake management (SBC/SBT): False
- With safety function Safe Operating Stop (SOS): False
- With safety function Safe Position (SP): False
- With safety function Safe programmable logic: False
- With safety function Safe Speed Monitor (SSM): False
- With safety function Safe Stop 1 (SS1): False
- With sft fct Safe Stop 2 (SS2): False
- With safety function Safe torque off (STO): True
- With safety function Safely Limited Position (SLP): False
- With safety function Safe Direction (SDI): False
Protection Type
- Thermal protection motor
- Safe torque off motor
- Motor phase break motor
- Thermal protection drive
- Safe torque off drive
- Overheating drive
- Overcurrent between output phases and earth drive
- Overload of output voltage drive
- Short-circuit protection drive
- Motor phase break drive
- Overvoltages on the DC bus drive
- Line supply overvoltage drive
- Line supply undervoltage drive
- Line supply phase loss drive
- Overspeed drive
- Break on the control circuit drive
Dimensions
Dimension Drawings: The document includes detailed dimension drawings for the drives. These show various views (front, side, top) with measurements in millimeters (mm) and inches (in.).
Drives Without Top Cover, With EMC Plate: Shows front, left, and rear views with specific dimensions provided.
Drives Without Top Cover, Without EMC Plate: Shows front, left, and rear views with specific dimensions provided.
Drives With IP20 Top Cover: Shows front, left, and rear views with specific dimensions provided.
Attribute | Value |
---|---|
Quantity per Set | 1 |
Width | 9.7 in (246 mm) |
Height | 16.5 in (420 mm) |
Depth | 9.5 in (242 mm) |
Net Weight | 48.5 lb(US) (22 kg) |
Environment
Attribute | Value |
---|---|
Insulation resistance | > 1 MOhm 500 V DC for 1 minute to earth |
Noise level | 52 dB (86/188/EEC) |
Environmental Data
Schneider Electric aims to achieve Net Zero status by 2050 through supply chain partnerships, lower impact materials, and circularity via its ongoing "Use Better, Use Longer, Use Again" campaign to extend product lifetimes and recyclability.
Environmental footprint
- Carbon footprint (kg CO2 eq, Total Life cycle): 4729
- Environmental Disclosure: Product Environmental Profile available
Materials and Substances
- Packaging made with recycled cardboard: Yes
- Packaging without single use plastic: No
- EU RoHS Directive: Pro-active compliance (Product out of EU RoHS legal scope)
- SCIP Number: 075941f9-bf60-4e63-ae5c-6fe3c8035357
- REACH Regulation: REACH Declaration
- California proposition 65: WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Energy efficiency
- Product contributes to saved and avoided emissions: Yes
Repack and remanufacture
- Circularity Profile: End of Life Information
- Take-back: No
- WEEE: The product must be disposed of in European Union markets following specific waste collection and never end up in rubbish bins.
Mounting and Clearance
Clearances: The diagram illustrates required clearances for mounting. X1 (front/rear) must be ≥ 100 mm (3.94 in.), X2 (sides) must be ≥ 100 mm (3.94 in.), and X3 (bottom) must be ≥ 10 mm (0.39 in.).
Mounting Types:
- Mounting Type A: Individual IP21 configuration, showing spacing 'a' between units.
- Mounting Type B: Side by Side IP20 configuration.
- Mounting Type C: Individual IP20 configuration.
Connections and Schema
Three-Phase Power Supply with Upstream Breaking via Line Contactor: This diagram shows the power connection with a line contactor (KM1), circuit breakers (Q2, Q3), pushbuttons (S1, S2), and a transformer (T1) for the control part. It conforms to standards EN 954-1 category 1 and IEC/EN 61508 capacity SIL1, stopping category 0 per IEC/EN 60204-1.
Three-Phase Power Supply with Downstream Breaking via Contactor: Similar to the upstream breaking diagram, this shows power connection with a line contactor (KM1), circuit breakers (Q2, Q3), pushbuttons (S1, S2), and a transformer (T1), conforming to the same standards.
Control Block Wiring Diagram: This diagram illustrates the internal wiring and connections. It shows terminals for digital inputs (DI1-DI6), digital outputs (R1A, R1B, R1C for fault relay; R2A, R2C; R3A, R3C for sequence relay), analog outputs (AQ1, AQ2), analog inputs (AI1, AI2, AI3), and safety functions like STOA/STOB for Safe Torque Off. It also indicates connections for a reference potentiometer.
Sensor Connection: It is possible to connect either 1 or 3 sensors on terminals Al2 or Al3.
Sink / Source Switch Configuration
The switch is used to adapt the operation of the logic inputs to the technology of the programmable controller outputs.
- Set the switch to Source (factory setting) if using PLC outputs with PNP transistors.
- Set the switch to Ext if using PLC outputs with NPN transistors.
The document shows four configurations:
- Switch Set to SRC (Source) Position Using the Output Power Supply for the Digital Inputs.
- Switch Set to SRC (Source) Position and Use of an External Power Supply for the DIs.
- Switch Set to SK (Sink) Position Using the Output Power Supply for the Digital Inputs.
- Switch Set to EXT Position Using an External Power Supply for the DIs.
Performance Curves
Derating Curves: This section presents derating curves that illustrate how the nominal drive current (In) is affected by switching frequency (SF) at different ambient temperatures. The curves show derating for Mounting types A, B, and C at 40°C (104°F), 50°C (122°F), and 60°C (140°F) for types B and C.
Ordering and Shipping Details
Attribute | Value |
---|---|
Category | US1CP4E22276 |
Discount Schedule | CP4E |
GTIN | 3606481325143 |
Returnability | Yes |
Country of origin | IN |
Packing Units
Attribute | Value |
---|---|
Unit Type of Package 1 | PCE |
Number of Units in Package 1 | 1 |
Package 1 Height | 29.53 in (75.000 cm) |
Package 1 Width | 23.62 in (60.000 cm) |
Package 1 Length | 31.50 in (80.000 cm) |
Package 1 Weight | 46.297 lb(US) (21.000 kg) |