KEYENCE FU Series Area Detection Fiber Sensors
With the addition of the new array sensor, the FU Series can now be used in an even wider range of applications.
Application Examples
The FU Series offers versatile detection capabilities:
- Stable detection of targets in varying positions: The sensor reliably detects objects even when their position or orientation changes.
- Positioning a workpiece with eccentricity: The sensor can detect objects that are not perfectly centered.
- Detecting a break in a vibrating wire: Demonstrates detection of fine or moving targets, such as a thin wire.
- Targets with holes: Highlights the sensor's capability to detect objects with gaps or holes.
[CE marking]
Array Sensors
Multiple micro-fibers are positioned side-by-side to achieve wide area detection.
Feature 1: Easy Installation
The beam covers a wide area providing easy optical axis alignment and hassle-free installation.
Graph: FU-A10 Parallel Movement Characteristics (Example) - Illustrates the ON/OFF detection range relative to the distance between light projection and reception units.
Feature 2: Excellent Environmental Resistance
Innovative design prevents dust and mist from damaging the unit. Rated IP67.
Flexible Cable
The cable can be placed in any direction to meet installation requirements.
Area Sensors
Light is diffused with a lens to cover a wide area.
Feature 1: Unaffected by Surrounding Objects
The thin beam makes it difficult for surrounding objects to influence the beam. Perfect for use in locations where sensors will be close to many devices.
Graph: FU-E11 Spot Length (Example) - Shows how the effective detection area width varies with the distance between sensors.
Feature 2: Uniform Intensity Distribution
Area sensors can stably sense minute changes in light intensity, making them ideal for small target detection.
Graph: Relationship between received and shielded light (Example) - Depicts how received light intensity changes as an object shields the light beam.
Slit Plate
Small targets can be detected using an optional metal slit plate to narrow the width and thickness of the beam. Available sizes include 30 mm x 0.5 mm and 20 mm x 0.5 mm.
Optical Axis Adjustment Mechanism
Both array and area sensors feature long mounting holes, allowing for optical axis adjustment even after mounting (except FU-11).
Latest Fiber Amp FS-V30 Series
The FS-V30 Series amplifiers offer advanced control and display features, including a Dual Digital Display, Mode Button, Output Selection Button, Operation Indicator, and Easy Power Control.
Cable Type
Appearance | Type | Model | NPN output | PNP output | ON/OFF outputs | External input | Analog output |
---|---|---|---|---|---|---|---|
Expansion unit | Standard | FS-V31 | 1 | FS-V31P | 1 | 0 | 0 |
2-output | FS-V32 | 2 | FS-V32P | 1 | 0 | 1 | |
Analog*1 | FS-V33 | FS-V33P | 2 | 1 | 0 | ||
Main unit | Standard | FS-V34 | FS-V34P | ||||
Expansion unit | Analog*1 | FS-V31M | 1 | 1 | 0 | 1 |
* The FS-V30 0-line expansion unit to support 0-line system is also available. *1 Received light intensity between 0 and 4,095 in HIGH SPEED, FINE, or TURBO mode is 1-5V.
Connector (M8) Type
Appearance | Type | Model | NPN output | PNP output | ON/OFF outputs | External input | Analog output |
---|---|---|---|---|---|---|---|
Expansion unit | Standard | FS-V31C | 1 | FS-V31CP | 1 | 1 | 0 |
FS-V32C | FS-V32CP | ||||||
Main unit | 2-output | FS-V33C | 2 | FS-V33CP | 0 | ||
Expansion unit | FS-V34C | FS-V34CP |
* To use the connector styled amplifier, purchase the connector cable OP-73864 or OP-73865.
For standard and analog output amplifiers, up to 16 expansion units can be added per main unit. For 2-output amplifiers, up to 7 expansion units can be added per main unit.
Useful Functions when using Area Detection Fiber Sensors
Edge Detection Function
The Edge Detection function detects changes in the intensity of received light. Because of this, it is not easily affected by dirt collecting on the sensors or temperature changes, and is able to provide stable, long-term detection.
Edge Detection Function Diagram: Illustrates how the sensor detects a workpiece by sensing a change in light intensity, showing 'No Workpiece' and 'Workpiece' states.
Attenuation Function
If the numbers on the display don't change as the workpiece passes through the sensor, it is possible that the intensity of received light is saturated. When this happens, minute changes may go undetected. With the FS-V30 Series, the intensity of projected light can be adjusted without changing the response speed.
Attenuation Function Diagram: Contrasts detection without attenuation (where light saturation prevents detecting small changes) with detection with attenuation (where projected light intensity is adjusted to allow detection of minute changes).
Specifications
Thrubeam
Type | Model | Optical axis dimensions (standard target) | MEGA | ULTRA | SUPER | Detecting distance (mm inch)*1 | Smallest detectable object *2 | Protective structure | Ambient temperature | Ambient humidity | Minimum bend radius | Tightening torque | Fiber length | Material | Weight | Accessories |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Array Thrubeam | FU-A05 | 6 x 0.3 mm 0.24" x 0.01" | 1100 (850) 43.31" (33.46") | 700 (530) 27.56" (20.87") | 420 (320) 16.54" (12.60") | TURBO: 300 (230) 11.81" (9.06") FINE: 220 (160) 8.66" (6.30") HSP: 100 (70) 3.94" (2.76") | Ø0.2 mm Ø0.008", opaque object | IP67 | 40 to +70C (-40 to 158F), No condensation | 35 to 85%RH, No condensation | R4 mm R0.16"*3 | 0.3 Nm | 2 m 6.6' (Free-cut) Ø2.2 Ø0.09" | Housing (main): Polybutylene terephthalate, Housing (end): Liquid crystal polymer, Core fiber: Acrylic, Fiber sheath: Polyethylene | Approx. 20 g | Mounting screws (M3 x 8), fiber cutter |
Array Thrubeam | FU-A10 | 11 x 0.3 mm 0.43" x 0.01" | 300 (230) 11.81" (9.06") | 220 (160) 8.66" (6.30") | 100 (70) 3.94" (2.76") | Ø0.4 mm Ø0.016", opaque object |
Area Thrubeam
Type | Model | Optical axis dimensions (standard target) | MEGA | ULTRA | SUPER | Detecting distance (mm inch)*1 | Smallest detectable object *2 | Ambient temperature | Ambient humidity | Minimum bend radius | Tightening torque | Fiber length | Material | Weight | Accessories | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Area Thrubeam | FU-E11 | With 1.0 mm 0.04" slit attached | 3600 (3600) 141.73" (141.73") | 3600 (3600) 141.73" (141.73") | 3400 (2400) 133.86" (94.49") | TURBO: 2200 (1600) 86.61" (62.99") FINE: 1600 (1200) 62.99" (47.24") HSP: 700 (500) 27.56" (19.69") | Ø0.2 mm Ø0.008", opaque object | 40 to +50C (-40 to 122F), No condensation | 35 to 85%RH, No condensation | R2 mm R0.08" | 0.15 Nm | 2 m 6.6' (Free-cut) Ø2.2 Ø0.09" | Housing: Polybutylene terephthalate, Screw attachment surface: SUS304*3, Lens: Norbornene-based resin, Core fiber: Acrylic, Fiber sheath: Polyethylene | Approx. 20 g | Mounting screws (M2 x 6), nuts (M2, t = 1.2) fiber cutter, slit (0.5 mm 0.02"/1.0 mm 0.04" wide) | ||
Area Thrubeam | FU-E40 | With 0.5 mm 0.02" slit attached | 3600 (3000) 141.73" (118.11") | 2000 (1600) 78.74" (62.99") | 1000 (800) 39.37" (31.50") | TURBO: 700 (500) 27.56" (19.69") FINE: 500 (350) 19.69" (13.78") HSP: 180 (100) 7.09" (3.94") | Ø0.4 mm Ø0.016", opaque object | ||||||||||
Slit for FU-E40 (OP-84365) | 30 x 0.5 mm 1.18" x 0.02" | Ø0.3 mm Ø0.01", opaque object | SUS304 | Approx. 4 g (weight of light projection/reception set) | OP-84365, OP-84366 | ||||||||||||
Slit for FU-E40 (OP-84366) | 20 x 0.5 mm 0.79" x 0.02" |
Reflective Type
Type | Model | Optical axis dimensions (standard target) | MEGA | ULTRA | SUPER | Detecting distance (mm inch)*1 | Smallest detectable object *2 | Protective structure | Ambient temperature | Ambient humidity | Minimum bend radius | Tightening torque | Fiber length | Material | Weight | Accessories |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Array Type | FU-A05D | White paper 400 x 400 mm 15.75" x 15.75" | 370 (260) 14.57" (10.24") | 230 (170) 9.06" (6.69") | 130 (110) 5.12" (4.33") | TURBO: 100 (70) 3.94" (2.76") FINE: 70 (50) 2.76" (1.97") HSP: 30 (20) 1.18" (0.79") | Ø0.005 Ø0.0002" gold wire | IP67 | 40 to +70C (-40 to 158F), No condensation | 35 to 85%RH, No condensation | R4 mm R0.16"*3 | 0.3 Nm | 2 m 6.6' (Free-cut) Ø2.2 Ø0.09" | Housing (main): Polybutylene terephthalate, Housing (end): Liquid crystal polymer, Core fiber: Acrylic, Fiber sheath: Polyethylene | Approx. 20 g | Mounting screws (M3 x 8), fiber cutter |
Array Type | FU-A10D | White paper 400 x 400 mm 15.75" x 15.75" | 370 (260) 14.57" (10.24") | 230 (170) 9.06" (6.69") | 130 (110) 5.12" (4.33") | TURBO: 100 (70) 3.94" (2.76") FINE: 70 (50) 2.76" (1.97") HSP: 30 (20) 1.18" (0.79") | Ø0.005 Ø0.0002" gold wire | |||||||||
Area Reflective Type | FU-11 | 5 to 160 (5 to 160) 0.20" to 6.30" (0.20" to 6.30") | 5 to 160 (5 to 160) 0.20" to 6.30" (0.20" to 6.30") | 5 to 150 (5 to 150) 0.20" to 5.91" (0.20" to 5.91") | 5 to 140 (5 to 130) 0.20" to 5.51" (0.20" to 5.12") | 5 to 120 (5 to 90) 0.20" to 4.72" (0.20" to 3.54") | 5 to 70 (5 to 55) 0.20" to 2.76" (0.20" to 2.17") | Ø0.1 Ø0.004" silver wire | R25 mm R0.98" | Housing: Polysulfone, Core fiber: Acrylic, Fiber sheath: Polyethylene, Lens: Arton | Approx. 19 g | Fiber cutter |
*1 When the FS-V30 Series is used. Each detecting distance in parentheses shows the data when the APC function is ON. *2 The smallest detectable object was determined at the optimal detecting distance and sensitivity setting. *3 R10 for the first 10 mm 0.39" of cable from the housing.
Sensor Lineups
Thrubeam Sensor Lineup
Type | Detection area width (mm inch) | Detection distance (mm inch)*1 | Smallest detectable object (mm inch)*2 | Minimum cable bend radius (mm inch) | Model |
---|---|---|---|---|---|
Array | 5 0.20" | MEGA: 1100 (850) 43.31" (33.46") FINE: 220 (160) 8.66" (6.30") | Ø0.2 mm Ø0.008", opaque object | R4 R0.16"*3 | FU-A05 |
10 0.39" | MEGA: 1100 (850) 43.31" (33.46") FINE: 220 (160) 8.66" (6.30") | FU-A10 | |||
Area | 11 0.43" | MEGA: 3600 (3600) 141.73" (141.73") FINE: 1600 (1200) 62.99" (47.24") | Ø0.2 mm Ø0.008", opaque object | R2 R0.08" | FU-E11 |
40 1.57" | MEGA: 3600 (3600) 141.73" (141.73") FINE: 1600 (1200) 62.99" (47.24") | FU-E40 |
*1 When the FS-V30 Series is used. The detecting distances in parentheses show the data when the APC function is ON. *2 The smallest detectable object was determined at the optimal detecting distance and sensitivity setting. *3 R10 R0.39" for the first 10 mm 0.39" of cable from the housing.
Reflective Sensor Lineup
Type | Detection area width (mm inch) | Detection distance (mm inch)*1 | Smallest detectable object (mm inch)*2 | Minimum cable bend radius (mm inch) | Model |
---|---|---|---|---|---|
Array | 10 0.39" (At a detection distance of 4 mm 0.16") | MEGA: 370 (260) 14.57" (10.24") FINE: 70 (50) 2.76" (1.97") | Ø0.005 Ø0.0002" gold wire | R4 R0.16"*3 | FU-A05D |
15 0.59" (At a detection distance of 4 mm 0.16") | MEGA: 370 (260) 14.57" (10.24") FINE: 70 (50) 2.76" (1.97") | FU-A10D | |||
Area | 15 0.59" (At a detection distance of 15 mm 0.59") | 5 to 160 (5 to 160) 0.20" to 6.30" (0.20" to 6.30") | Ø0.1 Ø0.004" silver wire | R25 R0.98" | FU-11 |
*1 When the FS-V30 Series is used. The detecting distances in parentheses show the data when the APC function is ON. *2 The smallest detectable object was determined at the optimal detecting distance and sensitivity setting. *3 R10 R0.39" for the first 10 mm 0.39" of cable from the housing.
Dimensions
Detailed dimensions for each model are provided below:
FU-A05
Width: 3.2 mm (0.13"), Mounting hole: Ø6 mm (0.24"), Cable length: 2 m (6.6'). Detection Area details provided.
FU-A10
Width: 3.2 mm (0.13"), Mounting hole: Ø6 mm (0.24"), Cable length: 2 m (6.6'). Detection Area details provided.
FU-E11
Optical axis: 7 mm (0.28"), Mounting hole: Ø6 mm (0.24"), Cable length: 2 m (6.6'). Detection Area: 2 x 11 mm (0.08" x 0.43").
FU-E40
Optical axis: 17.6 mm (0.69") / 12.6 mm (0.50"), Mounting hole: 3.6 x 5 mm (0.14" x 0.20"), Cable length: 2 m (6.6'). Detection Area: 3 x 40 mm (0.12" x 1.57") (with slit). Comes with 2 identical units.
FU-A05D
Width: 3.2 mm (0.13"), Mounting hole: Ø6 mm (0.24"), Cable length: 2 m (6.6'). Detection Area: 2 x 11 mm (0.08" x 0.43").
FU-A10D
Width: 3.2 mm (0.13"), Mounting hole: Ø6 mm (0.24"), Cable length: 2 m (6.6'). Detection Area: 2 x 11 mm (0.08" x 0.43").
FU-11
Mounting hole: 2-Ø3.3 mm (0.08"-0.13"), Cable length: 2 m (6.6').
For CAD data download: www.keyence.com/cad
Contact Information:
KEYENCE CORPORATION OF AMERICA
Corporate Office 50 Tice Blvd., Woodcliff Lake, NJ 07677
Phone: 201-930-0100 Fax: 201-930-0099 E-mail: keyence@keyence.com
KEYENCE CANADA INC.
Head Office Phone: 905-696-9970 Fax: 905-696-8340 E-mail: keyence@keyence.com
KEYENCE MEXICO S.A. DE C.V.
Phone: +52-81-8220-7900 Fax: +52-81-8220-9097 Email: keyencemexico@keyence.com
Specifications are subject to change without notice. Copyright (c) 2008 KEYENCE CORPORATION. All rights reserved.