Thermokon JOY Fancoil Modbus Series

Fancoil Regulators (from Version 4.x)

Product Overview

The Thermokon JOY Fancoil series offers advanced room thermostats designed for individual temperature control in commercial and residential buildings. These devices are tailored for two-pipe and four-pipe fan coil units and feature a modern design with a 2.5" LCD and a touch-sensitive surface. They support up to three time program options, each with four time periods.

JOY Fancoil 5DO (85..260 V~)

This model is designed for fan coil units with two-wire electric valves. It offers three normally open contacts for fan speed control and is suitable for controlling temperature in various building types.

JOY Fancoil EC AO2DO (85..260 V ~)

Designed for fan coil units with EC fans, this model supports 2- and 4-pipe systems. It includes 2 relays and 1 analog output (0-10V) for controlling heating valves, cooling valves, and EC fans.

JOY Fancoil EC 3AO (24 V ~/=)

This model is suitable for controlling two-wire electric valves or a 6-way valve. It is designed for individual temperature control in commercial, industrial, and residential buildings.

Key Features and Functions

Technical Data Summary

Parameter JOY Fancoil 5DO JOY Fancoil EC AO2DO JOY Fancoil EC 3AO
Power Supply 85..260 V ~ 85..260 V ~ 24 V = (±10%) or 24 V ~ (±10%) SELV
Output Switch Contact 3x NO (fan speed), 240 V, 3 A 2x NO (heating/cooling), 240 V, 500 mA N/A (uses analog outputs)
Analog Output N/A 1x 0..10 V (EC FAN control) 3x 0..10 V (heating/cooling/ 6-way valve)
Inputs DI1 (NTC10K/floating), DI2 (digital) DI1 (NTC10K/floating), DI2 (digital) DI1 (NTC10K/potential-free), DI2 (digital)

Mounting and Installation

Mounting Advise: Ensure the mounting box is sealed. Avoid installation in areas with air draughts, near heating sources, direct sunlight, or between furniture. Plasterboard boxes should be covered by wallpaper or paint to prevent the rim from being visible.

Electrical Connection: Terminals for power, fan control, and Modbus communication are clearly labeled. Ensure correct wiring, especially for 24V supplies, to avoid short circuits.

Software and Configuration

Firmware Updates: Updates can be performed using a MicroSD card. The device features an integrated bootloader for application loading.

Configuration: Thermokon's uConfig software (Windows 10 compatible) is used for parameterizing the device. Configuration files can be transferred via MicroSD card or Modbus interface.

Parameter Menu: Accessible via button combinations, allowing adjustments to time channels, date/time, sensor settings, and common device settings.

Security Advice

CAUTION: Installation and assembly of electrical equipment should only be performed by authorized personnel. Ensure all power is disconnected before installation. Risk of electric shock exists due to live components within the enclosure.

Disposal: Products must not be disposed of with household waste. Follow national laws for separate disposal.

Accessories

Optional accessories include frames for surface mounting (pure white and black) and decorative frames. A MicroSD card and RS485 biasing adapter are also available.

Models: 5DO, EC AO2DO, EC 3AO, JOY 5DO Room Controller, JOY 5DO, Room Controller, Controller

File Info : application/pdf, 9 Pages, 856.35KB

PDF preview unavailable. Download the PDF instead.

JOY Fancoil Modbus Datasheet en

References

Adobe PDF Library 25.1.51

Related Documents

Preview Thermokon JOY SR Fancoil Thermostat Datasheet
Technical datasheet for Thermokon JOY SR Fancoil thermostats, including models JOY SR 5DO, EC AO2DO, and EC 3AO with RS485 Modbus communication. Covers features, applications, technical specifications, installation, and configuration.
Preview Thermokon JOY SR Series Fancoil Thermostats Datasheet
Detailed datasheet for Thermokon JOY SR Series fancoil thermostats, including JOY SR 5DO, EC AO2DO, and EC 3AO models. Covers technical specifications, application, mounting, connection plans, function descriptions, configuration, and EnOcean integration for building automation systems.
Preview Thermokon JOY Fancoil Modbus RS485 Data Sheet
Technical data sheet for Thermokon JOY Fancoil 5DO, EC AO2DO, and EC 3AO RS485 Modbus fan coil thermostats. Includes application, safety, installation, technical specifications, and function descriptions.
Preview Thermokon JOY Fancoil RS485 BACnet Data Sheet
Technical data sheet for Thermokon JOY Fancoil controllers with RS485 BACnet interface, including models 5DO, EC AO2DO, and EC 3AO. Details specifications, application, safety, installation, and configuration.
Preview Thermokon JOY HC AO2DO/HC 3AO RS485 BACnet Room Regulator Datasheet
Datasheet for Thermokon's JOY HC AO2DO and JOY HC 3AO room regulators with RS485 BACnet connectivity. Details technical specifications, application, mounting advice, functions, and connection plans.
Preview Thermokon JOY HC AO2DO/HC 3AO RS485 Modbus Room Controller Datasheet
Technical datasheet for the Thermokon JOY HC AO2DO and JOY HC 3AO room controllers, featuring RS485 Modbus communication. Details technical specifications, application, safety instructions, installation, and configuration.
Preview Thermokon JOY KNX Room Operating Unit Manual
Comprehensive manual for the Thermokon JOY KNX room operating unit, covering installation, configuration, functional descriptions, operating modes, and KNX specifications.
Preview Thermokon LCF02 QTouch AO5DO Fancoil Controller Datasheet
Explore the technical specifications of the Thermokon LCF02 QTouch AO5DO fancoil controller, featuring a real glass display, optional CO2 sensing, and versatile fan and pipe system compatibility for optimal room climate control.