XBA-MOP4 Option Switch Settings
Supported bills: BDC 10, 20, 50, 100; BNU 10, 20, 50, 100 (4 bills).
XBA-MOP4 Option Switch Settings
FUNCTION | SW1 | SW2 | SW3 | SW4 | SW5 | SW6 | SW7 | SW8 |
---|---|---|---|---|---|---|---|---|
Reject MOP 10 | ON | |||||||
Accept MOP 10 | OFF | |||||||
Reject MOP 20 | ON | |||||||
Accept MOP 20 | OFF | |||||||
Reject MOP 50 | ON | |||||||
Accept MOP 50 | OFF | |||||||
Reject MOP 100 | ON | |||||||
Accept MOP 100 | OFF | |||||||
Reserved | ON | |||||||
Reserved | OFF | |||||||
Disable Bill Reject 4 Times | ON | |||||||
BA Stop By 30 Sec | OFF | |||||||
Enable Bill Reject 4 Times | ON | |||||||
BA Stop By 30 Sec | OFF | |||||||
Stack Banknote when Power-up | ON | |||||||
Reject Banknote when Power-up | OFF | |||||||
Reserved | ON | |||||||
Reserved | OFF |
Note 3: When Dip 1 is OFF, ICT106U MOP 10 = 0x40, MOP 20 = 0x41, MOP 50 = 0x42, MOP 100 = 0x43. When Dip 1 is ON, ICT106U MOP 20 = 0x40, MOP 50 = 0x41, MOP 100 = 0x42.
This dip switch is located at the side of XBA. The diagram shows a side view of the bill acceptor unit, indicating a DIP Switch labeled (2) and an LED indicator.
Currency Assign Data
Interface | ICT106U | ccNet | ICT104V | Pulse | MDB | |
---|---|---|---|---|---|---|
Bill value | When Dip 1 is OFF | When Dip 1 is ON | ||||
BV1 | 10=0x40 | 20=0x40 | 10 | 10 | 10 | 10 |
BV2 | 20=0x41 | 50=0x41 | 20 | 20 | 20 | 20 |
BV3 | 50=0x42 | 100=0x42 | 50 | 50 | 50 | 50 |
BV4 | 100=0x43 | 100 | 100 | 100 | 100 |
Appendix
XBA-MOP4 (Pulse/MDB/ICT/ccNet)
FUNCTION | SW1 | SW2 | SW3 | SW4 | SW5 | SW6 | SW7 | SW8 |
---|---|---|---|---|---|---|---|---|
Inhibit Active HIGH | ON | |||||||
Inhibit Active LOW | OFF | |||||||
Reserved | ON | |||||||
Reserved | OFF | |||||||
Reserved | ON | |||||||
Reserved | OFF | |||||||
Pulse Mode (Credit-Pulse Normal HIGH) | ON | |||||||
Pulse Mode (Credit-Pulse Normal LOW) | OFF | |||||||
Other Mode | ON | |||||||
Pulse Mode | MDB Mode | ccNet Mode | ICT104V Mode | |||||
1 pulse / MOP 10 | OFF | OFF | OFF | ON | ||||
5 pulses / MOP 10 | OFF | ON | ON | OFF | ||||
10 pulses / MOP 10 | ON | ON | ON | ON | ||||
20 pulses / MOP 10 | ON | OFF | ON | OFF |
This dip switch is located on the CPU board. To access it, remove the CPU board cover first. The diagram illustrates the process: first, an image of the bill acceptor with an arrow indicating cover removal, followed by an image of the CPU board with the DIP Switch labeled (1) highlighted.
Manufacture setting: After setting the dip switch for credit pulses, reset the bill acceptor. Note: 1. No sleep function is available. 2. A calibration card is needed.