P-SERIES SUBMITTAL DATA
Job Name: [Not Specified]
System Reference: [Not Specified]
Date: [Not Specified]
Product: Mitsubishi Electric PKA-A12HA7 & PUY-A12NKA7(-BS) - 12,000 BTU/H Wall-Mounted Air-Conditioning System
Indoor Unit Features
- Sleek, compact design
- Simple installation
- Vane setting for air flow direction control
- Auto fan speed mode
- Ideal for spaces such as server rooms, daycare centers, classrooms, churches, small offices, and more
Outdoor Unit Features
- Variable speed INVERTER-driven compressor
- Power receiver pre-charged with refrigerant volume for piping length up to 100 ft (70 ft. for A12/18/24/30)
- Low ambient cooling down to -40°F providing 100% capacity (only for PUY models with wind baffles installed)
- 24-hour continuous operation (cooling mode)
- High pressure protection
- Fast restarts in cooling mode (15 seconds for 12/18/36/42; 50 seconds for 24/30)
- Superior energy and operational efficiency
Specifications
Indoor Unit
Feature | Value |
---|---|
Maximum Capacity | 12,000 BTU/H |
Rated Capacity | 12,000 BTU/H |
Minimum Capacity | 5,800 BTU/H |
Maximum Power Input | 1,000 W |
Rated Power Input | 1,000 W |
Moisture Removal | 2.0 Pints/h |
Sensible Heat Factor | 0.81 |
Power Factor | 94.5 % |
SEER | 20.8 |
EER | 12.0 |
Voltage, Phase, Frequency | 208/230V, 1-phase, 60 Hz |
Guaranteed Voltage Range | 198-253 V AC |
Voltage: Indoor - Outdoor, S1-S2 | 208/230 V AC |
Voltage: Indoor - Outdoor, S2-S3 | 24 V DC |
Short-circuit Current Rating (SCCR) | 12 kA |
Recommended Fuse/Breaker Size (Outdoor) | 15 A |
Recommended Wire Size (Indoor - Outdoor) | 14 AWG |
MCA | 1 A |
Fan Motor Full Load Amperage | 0.33 A |
Fan Motor Output | 30 W |
Airflow Rate, Dry | 320-370-425 CFM |
Airflow Rate, Wet | 290-335-380 CFM |
External Static Pressure | n/a in.WG |
Sound Pressure Level | 36-40-43 dB(A) |
Drain Pipe Size | 5/8 (16) in. (mm) |
Condensate Lift Mechanism, Max. Distance | n/a in. (mm) |
Heat Exchanger Type | Plate fin coil |
External Finish Color | White Munsell 1.0Y 9.2/0.2 |
Unit Dimensions (W x D x H) | 35-3/8 (898) x 9-13/16 (249) x 11-5/8 (295) in. (mm) |
Package Dimensions (W x D x H) | 39-6/16 x 15-12/16 x 13-6/16 in. |
Unit Weight | 29 (13) Lbs. (kg) |
Package Weight | 33 Lbs. |
Cooling Intake Air Temp (Max / Minimum) | 90°F DB / 66°F DB, 73°F WB / 59°F WB |
MCA (Outdoor Unit) | 11 A |
MOCP (Outdoor Unit) | 28 A |
Fan Motor Full Load Amperage (Outdoor Unit) | 0.50 A |
Outdoor Unit
Feature | Value |
---|---|
Fan Motor Output | 46 W |
Airflow Rate | 1,590 CFM |
Refrigerant Control | Electronic Expansion Valve |
Heat Exchanger Type | Cross fin |
Sound Pressure Level, Cooling | 44 dB(A) |
Compressor Type | INVERTER-driven twin rotary |
Compressor Model | SNB092FNCM |
Compressor Rated Load Amps | 7 A |
Compressor Locked Rotor Amps | 12 A |
Compressor Oil Type // Charge | FV50S // 12 oz. |
External Finish Color | Ivory Munsell 3Y 7.8/1.1 |
Base Pan Heater | n/a |
Unit Dimensions (W x D x H) | 31-13/16 + 7/16 (809+62) x 11-3/16 (300) x 24-13/16 (630) in. (mm) |
Package Dimensions (W x D x H) | 37-1/16 x 16-3/16 x 27-7/16 in. |
Unit Weight | 92 (41) Lbs. (kg) |
Package Weight | 104 (47) Lbs. (kg) |
Cooling Intake Air Temp (Maximum / Minimum) | 115°F DB / -40°F DB |
Refrigerant Type | R410A |
Refrigerant Charge | 4 lbs, 7 oz |
Gas Pipe Size O.D. (Flared) | 1/2 (12.7) in.(mm) |
Liquid Pipe Size O.D. (Flared) | 1/4 (6.35) in.(mm) |
Maximum Piping Length | 165 (50) Ft. (m) |
Maximum Height Difference | 100 (30) Ft. (m) |
Maximum Number of Bends | 15 |
Key Notes
- AHRI Rated Conditions (Cooling): Indoor: 80°F DB, 67°F WB; Outdoor: 95°F DB, 75°F WB.
- Low Ambient Operation: Wind baffles are required for operation below 23°F DB in cooling mode. For PUY models, wind baffles can extend the cooling operation range to -40°F.
- System Protection: The system may cut out in heating mode to prevent thermistor errors and will automatically restart.
- Seacoast Protection: Features include Phosphate coating + Acrylic-Enamel coating on the external outer panel, Epoxy resin coating on the fan motor support and separator assembly/valve bed, and "Blue Fin" treatment on the condenser coil for enhanced corrosion resistance.
Available Accessories
A comprehensive range of accessories is available for the PKA-A12HA7 indoor unit and PUY-A12NKA7(-BS) outdoor unit, including various remote controllers, sensors, condensate pumps, mounting brackets, and piping kits. Specific part numbers are listed in the original documentation.
Dimensions and Clearances
Indoor Unit (PKA-A12HA7)
Unit Dimensions: Width: 35-3/8 inches (898 mm), Depth: 9-13/16 inches (249 mm), Height: 11-5/8 inches (295 mm).
Package Dimensions: Width: 39-6/16 inches, Depth: 15-12/16 inches, Height: 13-6/16 inches.
Required Space: Specific clearances are indicated in diagrams for air inlet and outlet, as well as piping access. For example, minimum air inlet clearance is 1-31/32 inches (50 mm) and minimum air outlet clearance is 8-5/8 inches (220 mm).
Outdoor Unit (PUY-A12NKA7(-BS))
Unit Dimensions: Width: 809 mm (31-7/8 inches), Depth: 300 mm (11-13/16 inches), Height: 630 mm (24-13/16 inches).
Installation Clearances: The unit requires free space around it for proper operation. Generally, 100mm (3-15/16 inches) or more is recommended on the rear and sides if there are no obstacles. Piping and wiring connections are made from the rear.
Foundation: The unit must be secured firmly with 4 foundation bolts (M10, W 3/8). Recommended foundation bolt height is a minimum of 100mm (3-15/16 inches).