SUBMITTAL DATA: PLA-A24EA7 & PUY-A24NHA7(-BS)

SUBMITTAL DATA: PLA-A24EA7 & PUY-A24NHA7(-BS)

Explantion of particular details are given in the installation manuals etc. ø ø. FOUNDATION. OCH636. Unit: mm. FORM# PLA-A24EA7 / PUY-A24NHA7(-BS) ...

PLA-A24EA7 & PUY-A24NHA7(-BS) - AC Direct

2021-02-28 — 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. P-SERIES ... Thermostat Interface. □ PAC-US444CN-1 ... can be made from 4 directions:.

PDF preview unavailable. Download the PDF instead.

PLA-A24EA7 PUY-A24NHA7
P-SERIES
Job Name: System Reference:
Indoor Unit: PLA-A24EA7

SUBMITTAL DATA: PLA-A24EA7 & PUY-A24NHA7(-BS)
24,000 BTU/H CEILING-CASSETTE AIR-CONDITIONING SYSTEM

Outdoor Unit:  PUY-A24NHA7  PUY-A24NHA7-BS

Date:

INDOOR UNIT FEATURES · Space-efficient ductless installation · Equipped with 3D i-see Sensor® for enhanced comfort and energy efficiency · Airflow settings for high and low ceiling applications · Individual vane settings for direct/indirect airflow control or variable airflow patterns · Knockouts for outside-air intake and branch-duct run · Filter indicator signal · Easy-to-clean, washable filter (optional high-efficiency filter available - requires multi-function casement) · Built-in condensate lift mechanism · Ideal for retail shops, classrooms, office spaces, conference centers, building lobbies, and more
OUTDOOR UNIT FEATURES · Variable speed INVERTER-driven compressor · Power receiver pre-charged with refrigerant volume for piping length up to 100 ft (70 ft. for A12/18/24/30) · Low ambient cooling down to -40ºF providing 100% capacity (only for PUY models with wind baffles installed) · 24-hour continuous operation (cooling mode) · High pressure protection · Fast restarts in cooling mode (15 seconds for 12/18/36/42; 50 seconds for 24/30) · Superior energy and operational efficiency

Specifications are subject to change without notice.

© 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.

SPECIFICATIONS: PLA-A24EA7 & PUY-A24NHA7(-BS)

Cooling1 Efficiency Electrical
Indoor Unit
Indoor Unit Operating Temperature Range Outdoor Unit

Maximum Capacity

BTU/H

Rated Capacity

BTU/H

Minimum Capacity

BTU/H

Maximum Power Input

W

Rated Power Input

W

Moisture Removal

Pints/h

Sensible Heat Factor

Power Factor

%

SEER

EER1

ENERGY STAR® Certified (ENERGY STAR products are third-party certified by an EPA-recognized Certification Body)

Voltage, Phase, Frequency

Guaranteed Voltage Range

V AC

Voltage: Indoor - Outdoor, S1-S2

V AC

Voltage: Indoor - Outdoor, S2-S3

V DC

Short-circuit Current Rating (SCCR)

kA

Recommended Fuse/Breaker Size (Outdoor)

A

Recommended Wire Size (Indoor - Outdoor)

AWG

MCA

A

Fan Motor Full Load Amperage

A

Fan Motor Output

W

Airflow Rate, Dry

CFM

Airflow Rate, Wet

CFM

External Static Pressure

in.WG

Sound Pressure Level

dB(A)

Drain Pipe Size

In. (mm)

Condensate Lift Mechanism, Max. Distance

In.

Heat Exchanger Type

External Finish Color

W: In. (mm)

Unit Dimensions // Grille Dimensions

D: In. (mm)

H: In. (mm)

W: In. (mm)

Package Dimensions // Grille Dimensions

D: In. (mm)

H: In. (mm)

Unit Weight // Grille Weight

Lbs. (kg)

Package Weight

Lbs. (kg)

Cooling Intake Air Temp (Maximum / Minimum)

°F

MCA

A

MOCP

A

24,000 24,000 10,000 1,670 1,670
3.0 0.86 94.3 24.2 14.3 Yes
208 / 230V, 1-phase, 60 Hz 198 ­ 253 208 / 230 24 12 25 14 1.00 0.60 120
530-640-710-810 490-600-670-770
n/a 28-30-33-36
1-1/4 (32) 33-7/16 Plate fin coil White Munsell 6.4Y 8.9/0.4 33-1/16 (840) // 37-13/32 (950) 33-1/16 (840) // 37-13/32 (950) 11-3/4 (298) // 1-9/16 (40) 35-9/16 // 39-6/16 34-5/16 // 38-3/16 16-9/16 // 4-12/16 56 (25) // 11 (5) 68 (31) 90 DB, 73 WB / 66 DB, 59 WB
19 26

Specifications are subject to change without notice.

© 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.

SPECIFICATIONS: PLA-A24EA7 & PUY-A24NHA7(-BS)

Fan Motor Full Load Amperage Fan Motor Output Airflow Rate Refrigerant Control Heat Exchanger Type Sound Pressure Level, Cooling1 Compressor Type Compressor Model Compressor Rated Load Amps Compressor Locked Rotor Amps Compressor Oil Type // Charge External Finish Color Base Pan Heater
Unit Dimensions

Package Dimensions

Unit Weight

Package Weight

Outdoor Unit Operating Cooling Intake Air Temp (Maximum / Minimum) Temperature Range

Refrigerant

Type Charge

Gas Pipe Size O.D. (Flared)

Liquid Pipe Size O.D. (Flared)

Piping

Maximum Piping Length

Maximum Height Difference

Maximum Number of Bends

A W CFM
dB(A)
A A oz.
W: In. (mm) D: In. (mm) H: In. (mm) W: In. (mm) D: In. (mm) H: In. (mm)
Lbs. (kg) Lbs. (kg)
°F
Lbs, oz In.(mm) In.(mm) Ft. (m) Ft. (m)

0.40 86 1,940 Electronic Expansion Valve Cross fin 47 INVERTER-driven twin rotary SNB172FWHM1 7 11 FV50S // 23 Ivory Munsell 3Y 7.8/1.1 n/a 37-13/32 (950) 13 + 1-3/16 (330 + 30) 37-1/8 (943) 40-15/16 17-11/16 40-11/16 151 (68) 176 (80) 115 DB / -40* DB
R410A 7 lbs, 11 oz 5/8 (15.88) 3/8 (9.52)
225 (69) 100 (30)
15

Notes

AHRI Rated Conditions (Rated data is determined at a fixed compressor speed)

1Cooling (Indoor // Outdoor)

°F

80 DB, 67 WB // 95 DB, 75 WB

*Wind baffles required to operate below 23°F DB in cooling mode. For PUY models, wind baffles can be utilized to extend the cooling operation range to -40F. Please refer to the wind baffle submittals to determine which baffles are required to meet the desired operation range.
**System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures.

SEACOAST PROTECTION · External Outer Panel: Phosphate coating + Acrylic-Enamel coating · Fan Motor Support: Epoxy resin coating (at edge face) · Separator Assembly; Valve Bed: Epoxy resin coating (at edge face) · "Blue Fin" treatment is an anti-corrosion treatment that is applied to the condenser coil to protect it against airborne contaminants.

Specifications are subject to change without notice.

© 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.

ACCESSORIES: PLA-A24EA7

High-efficiency Filter Element

 PAC-SH59KF-E

Wireless Remote Receiver

 PAR-FA32MA-W

Wireless Remote Receiver

 PAR-FA32MA-E

Signal Receiver

 PAR-SR3LA-E

kumo touchTM RedLINKTM Wireless Controller

 MHK2

Deluxe MA Remote Controller

 PAR-40MAAU

Simple MA Controller

 PAC-YT53CRAU-J

Touch MA Controller

 PAR-CT01MAU-SB

Wired Remote Sensor

 PAC-SE41TS-E

Lockdown Bracket for Wireless, Hand-held, Remote Controller

 RCMKP1CB

Wireless Temperature and Humidity Sensor

 PAC-USWHS003-TH-1

Flush Mount Remote Temperature Sensor

 PAC-USSEN001-FM-1

Wireless Interface 2

 PAC-USWHS002-WF-2

Thermostat Interface

 PAC-US444CN-1

kumo station®

 PAC-WHS01HC-E

USNAP Interface

 PAC-WHS01UP-E

IT Extender

 PAC-WHS01IE-E

BACnet® and MODBUS® Interface

 PAC-UKPRC001-CN-1

External Fan / Heater Control Relay Adapter

 CN24RELAY-KIT-CM3

Connector for CN32 (remote on/off)

 PAC-SE55RA-E

Remote Operation Adapter (with wire terminals for remote ON/OFF and operation status/ error)1

 PAC-SF40RM-E

Grille (required)

 PLP-40EAEU

Multi-Function Casement

 PAC-SJ41TM-E

Installation/Trim Panels

 PLFY-ITP1

Space Panel

 PAC-SJ38AS-E

Air Outlet Shutter Plate

 PAC-SJ37SP-E

Blue Diamond Sensor Extension Cable--15 Ft.

 C13-103

MegaBlue Advanced Blue Diamond Condensate Pump w/ Reservoir & Sensor

 X87-835 - 110 to 250V

MaxiBlue Advanced Blue Diamond Mini Condensate Pump w/ Reservoir & Sensor (208/230V) up to 48,000 BTU/H  X87-721 - 208/230V [recommended]

3 Pole Disconnect Switch (30A/600VUL) [fits 2"X4" utility] - Black

 TAZ-MS303

3 Pole Disconnect Switch (30A/600VUL) [fits 2"X4" utility] - White 1 Unable to use with wireless remote controller

 TAZ-MS303W

Specifications are subject to change without notice.

© 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.

ACCESSORIES: PUY-A24NHA7(-BS)
Twinning Distribution Pipe (50:50) Air Outlet Guide Front Wind Baffle Side Advanced Wind Baffle Rear Advanced Wind Baffle Drain Socket Centralized Drain Pan M-NET Converter M-NET Converter Control/Service Tool Hail Guard Condensing Unit Mounting Pad 24" x 42" x 3" Outdoor Unit Stand--12" High Outdoor Unit Stand--18" High Outdoor Unit Stand--24" High Heavy Duty Wall Mounting Bracket for Outdoor Units--Coated Steel Heavy Duty Wall Mounting Bracket for Outdoor Units--316 Series Stainless Steel 3/8" x 5/8" x 10' / 1/2" Lineset (Twin-Tube Insulation) 3/8" x 5/8" x 15' / 1/2" Lineset (Twin-Tube Insulation) 3/8" x 5/8" x 30' / 1/2" Lineset (Twin-Tube Insulation) 3/8" x 5/8" x 50' / 1/2" Lineset (Twin-Tube Insulation) 3/8" x 5/8" x 65' / 1/2" Lineset (Twin-Tube Insulation) 3/8" x 5/8" x 100' / 1/2" Lineset (Twin-Tube Insulation)

 MSDD-50TR-E  PAC-SG59SG-E  WB-PA5  WB-SD5  WB-RE5  PAC-SG61DS-E  PAC-SG64DP-E  PAC-SJ85MA-E  PAC-SJ95MA-E  PAC-SK52ST  HG-A6  ULTRILITE2  QSMS1201M  QSMS1801M  QSMS2401M  QSWB2000M-1  QSWBSS  MPLS385812T-10  MPLS385812T-15  MPLS385812T-30  MPLS385812T-50  MPLS385812T-65  MPLS385812T-100

Specifications are subject to change without notice.

© 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.

6 OUTLINES AND DIMENSIONS
120°

DIMENSIONS: PLA-A24EA7

NOTE1.CHOOSE THE GRILLE AMONG THE DEDICATED GRILLES. 2.REINFORCE THE SUSPENSION BOLT FOR EARTHQUAKE-RESISTANCE AS NEEDED.
3.FOR THE SUSPENSION BOLT, USE M10 OR W3/8.
(PROCURED AT THE LOCAL SITE.)
4.FOR DRAIN PIPE, USE VP-25(O.D. n1-1/4''( { 32) PVC TUBE). DRAIN PUMP INCLUSION. RAISE IS MAX 33-7/16''(850mm) FROM THE CEILING.
5.ELECTRICAL BOX MAY BE REMOVED FOR THE SERVICE PURPOSE. MAKE SURE TO SLACK THE ELECTRICAL WIRE LITTLE BIT FOR CONTROL/POWER WIRES CONNECTION. 6.THE HEIGHT OF THE INDOOR UNIT IS ABLE TO BE ADJUSTED WITH THE GRILLE ATTACHED. 7.REQUIRES "E" OR MORE SPACE BETWEEN TRANSOM AND CEILING FOR THE INSTALLATION. 8.WHEN INSTALLING THE BRANCH DUCTS, BE SURE TO INSULATE ADEQUATELY. OTHERWISE CONDENSATION AND DRIPPING MAY OCCUR.
(IT BECOMES THE CAUSE OF DROPLET OR DROPLET DRIPPING.)
9.AS FOR NECESSARY INSTALLATION/SERVICE SPACE, PLEASE REFER TO THE RIGHT AT FIGURE.
10.FOR THE INSTALLATION OF THE OPTIONAL HIGH EFFICIENCY FILTER OR MULTI-FUNCTIONAL CASEMENT,REFER TO SPECIAL DRAWING.

1-7/16(37)

(89) 3-1/2

OPTIONAL PART:SIGNAL RECEIVER
20(508) (AIR INTAKE HOLE)

CORNER POCKET VANE MOTOR

WALL
CEILING GRILLE

INDOOR UNIT OBSTACLE

INDOOR UNIT

BETWEEN THE TOP OF UNIT AND CEILING SLAB

118-1/8(3000mm) OR MORE BETWEEN INDOOR UNIT
70-7/8(1800mm) OR MORE FROM FLOOR

F
CEILING HEIGHT

(1000mm) 39-3/8 OR MORE

GRILLE

59-1/16(1500mm) OR MORE
CEILING REMOTE CONTROLLER WIRE ENTRY

FLOOR (20-45)
13/16 TO 1-3/4 REMOTE CONTROLLER WIRE ENTRY

BRANCH DUCT HOLE

(CEILING HOLE) 33-7/8 TO 35-13/16(860-910)

31-5/16 (795)

(145) 5-11/16

(SUSPENSION BOLT PITCH)

(145) 5-11/16

70° AIR INTAKE GRILLE

REMOTE CONTROLLER TERMINAL BLOCK

(20-45) 13/16 TO 1-3/4
FRESH AIR INTAKE HOLE

(7mm) 1/4 OR MORE
E
SPACE IN THE CEILING

(20) 13/16

(20-45) 13/16 TO 1-3/4

15-3/8(390) (100)
3-15/16 (90) 3-9/16

Unit: inch (mm)

DETAILS OF FRESH AIR INTAKE HOLE

{3-15/16({100) CUTOUT HOLE

120°

{4-15/16({125) BURRING HOLE PITCH SELF-TAP 4 SCREWS:3 PLACES

6-1/4 (158)

CEILING

(167) 6-9/16
(155) 6-1/8
70°

CEILING GRILLE
{6-7/8({175) BURRING HOLE PITCH SELF-TAP 4 SCREWS:4 PLACES (CONNECTING TO BRANCH DUCT)
{5-7/8({150) CUTOUT HOLE (CONNECTING TO BRANCH DUCT)

17-11/16(450)

(350) 13-3/4

33-7/8 TO 35-13/16(860-910) (CEILING HOLE)

+1-9/16 0

26

(660+040)

(SUSPENSION BOLT PITCH)

33-1/16(840)

20(508) (AIR INTAKE HOLE)

37-3/8(950) 20-7/8(530) (AIR OUTLET HOLE)

(100) 3-15/16

BRANCH DUCT HOLE

INDOOR UNIT/ OUTDOOR UNIT CONNECTING TERMINAL BLOCK

BRANCH DUCT HOLE

(90) 3-9/16

(133) 5-1/4

(20) 13/16

1-7/16 3-1/2

(89)

DRAIN HOLE

(37)

COMPANY NAME

(AIR OUTLET HOLE) 20-7/8(530)
37-3/8(950)

AUTO VANE

I-SEE SENSOR CORNER PANEL
SOME GRILLES DO NOT HAVE THIS PART. *CAN INSTALL TO THE CORNER
EXCEPT DRAIN PIPE CORNER (NEED TO FUNCTION SETTING BY REMOTE CONTROLLER)

{5-7/8({150) CUTOUT HOLE (CONNECTING TO BRANCH DUCT)
{6-7/8({175) BURRING HOLE PITCH SELF-TAP 4 SCREWS:4 PLACES (CONNECTING TO BRANCH DUCT)

(193) 7-5/8
(222) 8-3/4

BRANCH DUCT HOLE 33-1/16(840)

SUSPENSION BOLT M10 OR W3/8

(60) 2-3/8

MAIN UNIT 24-3/4(628)

PLA-A.EA7*:12/18/24/30/36/42

2

MODELS

REFRIGERANT PIPE6.35 FLARED CONNECTION 1/4F
REFRIGERANT PIPE9.52 FLARED CONNECTION 3/8F

REFRIGERANT PIPE{12.7 FLARED CONNECTION 1/2F
REFRIGERANT PIPE{15.88 FLARED CONNECTION 5/8F

A

B

9-1/2 10-3/16 (241) (258)

11-1/16 11-3/4 (281) (298)

CD

E

3(76)

3(76.5)

10-7/16(265) OR MORE

3-1/8

12(305)

(79.5)

OR MORE

F 137-13/16(3500) OR LESS 177-3/16(4500) OR LESS

DETAILS OF SIGNAL RECEVER
EMERGENCY OPERATION SWITCH <COOLING>AND EMERGENCY UP/DOWN SWITCH<UP>

RECEIVER

OPERATION LAMP

EMERGENCY OPERATION SWITCH <HEATING>AND EMERGENCY UP/DOWN SWITCH<DOWN>
DEFROST/STAND BY LAMP

(170) 6-11/16 (140) 5-1/2

1

THE BOTTOM OF I-SEE SENSOR SUSPENSION BOLT LOWER EDGE

INDOOR UNIT/OUTDOOR UNIT CONNECTING WIRE, POWER SUPPLY WIRE ENTRY

(145) 5-11/16
DRAIN PIPE VP-25 CONNECTION (CONNECTED THE ATTACED DRAIN SOCKET)

GRILLE

CEILING

1/4(6) 5-11/16(145)

4-1/8 (105)

3-1/8(79.5)

D C

(17+05)

11/16

+3/16 0

(190) 7-1/2
A B

1-9/16 (40)

(20-45) 13/16 TO 1-3/4

(100) 3-15/16

(130) 5-1/8

SELF-TAP 4 SCREWS:14 PLACES (CONNECTING TO BRANCH DUCT)
13-3/4×3-15/16(350×100) CUTOUT HOLE (CONNECTING TO BRANCH DUCT)

(50-70) 1-15/16 TO 2-3/4
2-5/16 (58)

Specifications are subject to change without notice.

© 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.

PUZ-A24NHA7 PUZ-A24NHA7-BS

OCH636

PUZ-A30NHA7 PUZ-A30NHA7-BS

DIMENSIONS: PUY-A24NHA7(-BS)

FREE
Min. 500 <19-11/16>
Min. 100 <3-15/16> Max. 30 <1-3/16>

1 FREE SPACE (Around the unit)
The diagram below shows a basic example. Explantion of particular details are given in the installation manuals etc.

2 SERVICE SPACE
Dimensions of space needed for service access are shown in the below diagram.

Min. 10mm <3/8> Min. 500mm <19-11/16>

Min. 10mm <3/8>
Min.100mm <3-15/16>

Min. 10 <13>
Service space Min. 500 <19-11/16>

Example of Notes

Handle for moving

1 ... Refrigerant GAS pipe connection (FLARE) ø15.88(5/8F) 2 ... Refrigerant LIQUID pipe connection (FLARE) ø 9.52(3/8F) *1... Indication of STOP VALVE connection location.
Air Intake

3 FOUNDATION BOLTS

4 PIPING-WIRING DIRECTIONS

Please secure the unit firmly with 4 foundation (M10<W3/8>) bolts. (Bolts and washers must be purchased locally.)

Piping and wiring connections can be made from 4 directions: FRONT,Right,Rear and Below.

<Foundation bolt height>

175 <6-7/8>
Side Air Intake

Rear Air Intake
600<23-5/8> Installation Feet

Unit: mm<in>
2-U Shaped notched holes (Foundfation Bolt M10<W3/8>) 175<6-7/8>

19 <3/4> 370<14-9/16> 417 <1-1/32>

330 <13>

FOUNDATION
Rear Air Intake Handle for moving

28<1-3/32>

25 <31/32>

Air Discharge

70 <2-3/4> 57<2-1/4>

61<2-13/32> 40<19/32> 0 53<2-3/32>
41 <1-5/8>

2-12×36 oval holes (Foundation Bolt M10<W3/8>)

Handle Side Air Intake for moving

950 <37-13/32> 322<12-11/16> Earth terminal

LTeerftm..in. aPloCwoenrnseucptpiolynswiring Reight ... Indoor/Outdoor wiring
Service panel Handle for moving

1 2

*1 431<16-31/32> *1 447<17-5/8>
669<26-11/32>

943 <37-1/8> 473 <18-5/8> 23 <29/32>

Piping knockout Hole Details

Power supply wiring hole (2-ø27knockout) Front trunking hole 40<1-9/16> (knockout)

45 <1-25/32>

Right piping hole (knockout)
75 <2-31/32>

Power supply wiring hole (2- ø27knockout)

Right trunking hole (knockout)

40<1-9/16>

45<1-25/32>

73 <2-7/18> 63 <2-1/2>
55 <2-3/16>

63 <2-1/2>

63<2-1/2> 55<2-3/16>

73 <2-7/8>

Front piping hole (knockout)

<3ø-952/8>
92<3-5/8> 65 <2-9/16>

19<3/4>

ø 92 <3-5/8>
92 <3-5/8> 55 <2-3/16>

Power supply wiring hole (2- ø27<1-1/16>knockout) 40<1-9/16> Rear trunking hole (knockout)
ø92 <3-5/8>
Rear piping hole (knockout)
92 <3-5/18> 65 <2-9/16>

Set the attachment to the When installing the conduit, inner side of each panel.
1/2 Conduit attachment 2-ø22.2<7/8>
40<1-9/16> 74<2-19/32>

31<1-7/32>

71 <2-13/16>

71<2-13/16>

Front piping cover Rear piping cover

Bottom piping hole (knockout)

219 <8-5/8>

81<3-3/16>

30 <1-3/16>

220

145

145

145

<8-21/32> <5-23/32><5-23/32><5-23/32>

Drain hole (5- ø33<1-5/16>)

15

PUY-A24NHA7 PUY-A24NHA7-BS

27 23 <29/32> <1-1/16> 92 <3-5/8>

23 <29/32> 27<1-1/16>

73 <2-7/18>

27<1-1/16>

23 <29/32>

PUY-A30NHA7 PUY-A30NHA7-BS

FORM# PLA-A24EA7 / PUY-A24NHA7(-BS) - 202003
Specifications are subject to change without notice.

1340 Satellite Boulevard, Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com
© 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.


AH XSL Formatter V6.6 R1 for Linux64 : 6.6.1.34539 (2018/08/29 13:12JST) Antenna House PDF Output Library 6.6.1307 (Linux64)