Explantion of particular details are given in the installation manuals etc. ø ø. FOUNDATION. OCH636. Unit: mm. FORM# PLA-A24EA7 / PUY-A24NHA7(-BS) ...
2021-02-28 — 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. P-SERIES ... Thermostat Interface. □ PAC-US444CN-1 ... can be made from 4 directions:.
P-SERIES Job Name: System Reference: Indoor Unit: PLA-A24EA7 SUBMITTAL DATA: PLA-A24EA7 & PUY-A24NHA7(-BS) 24,000 BTU/H CEILING-CASSETTE AIR-CONDITIONING SYSTEM Outdoor Unit: PUY-A24NHA7 PUY-A24NHA7-BS Date: INDOOR UNIT FEATURES · Space-efficient ductless installation · Equipped with 3D i-see Sensor® for enhanced comfort and energy efficiency · Airflow settings for high and low ceiling applications · Individual vane settings for direct/indirect airflow control or variable airflow patterns · Knockouts for outside-air intake and branch-duct run · Filter indicator signal · Easy-to-clean, washable filter (optional high-efficiency filter available - requires multi-function casement) · Built-in condensate lift mechanism · Ideal for retail shops, classrooms, office spaces, conference centers, building lobbies, and more OUTDOOR UNIT FEATURES · Variable speed INVERTER-driven compressor · Power receiver pre-charged with refrigerant volume for piping length up to 100 ft (70 ft. for A12/18/24/30) · Low ambient cooling down to -40ºF providing 100% capacity (only for PUY models with wind baffles installed) · 24-hour continuous operation (cooling mode) · High pressure protection · Fast restarts in cooling mode (15 seconds for 12/18/36/42; 50 seconds for 24/30) · Superior energy and operational efficiency Specifications are subject to change without notice. © 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. SPECIFICATIONS: PLA-A24EA7 & PUY-A24NHA7(-BS) Cooling1 Efficiency Electrical Indoor Unit Indoor Unit Operating Temperature Range Outdoor Unit Maximum Capacity BTU/H Rated Capacity BTU/H Minimum Capacity BTU/H Maximum Power Input W Rated Power Input W Moisture Removal Pints/h Sensible Heat Factor Power Factor % SEER EER1 ENERGY STAR® Certified (ENERGY STAR products are third-party certified by an EPA-recognized Certification Body) Voltage, Phase, Frequency Guaranteed Voltage Range V AC Voltage: Indoor - Outdoor, S1-S2 V AC Voltage: Indoor - Outdoor, S2-S3 V DC Short-circuit Current Rating (SCCR) kA Recommended Fuse/Breaker Size (Outdoor) A Recommended Wire Size (Indoor - Outdoor) AWG MCA A Fan Motor Full Load Amperage A Fan Motor Output W Airflow Rate, Dry CFM Airflow Rate, Wet CFM External Static Pressure in.WG Sound Pressure Level dB(A) Drain Pipe Size In. (mm) Condensate Lift Mechanism, Max. Distance In. Heat Exchanger Type External Finish Color W: In. (mm) Unit Dimensions // Grille Dimensions D: In. (mm) H: In. (mm) W: In. (mm) Package Dimensions // Grille Dimensions D: In. (mm) H: In. (mm) Unit Weight // Grille Weight Lbs. (kg) Package Weight Lbs. (kg) Cooling Intake Air Temp (Maximum / Minimum) °F MCA A MOCP A 24,000 24,000 10,000 1,670 1,670 3.0 0.86 94.3 24.2 14.3 Yes 208 / 230V, 1-phase, 60 Hz 198 253 208 / 230 24 12 25 14 1.00 0.60 120 530-640-710-810 490-600-670-770 n/a 28-30-33-36 1-1/4 (32) 33-7/16 Plate fin coil White Munsell 6.4Y 8.9/0.4 33-1/16 (840) // 37-13/32 (950) 33-1/16 (840) // 37-13/32 (950) 11-3/4 (298) // 1-9/16 (40) 35-9/16 // 39-6/16 34-5/16 // 38-3/16 16-9/16 // 4-12/16 56 (25) // 11 (5) 68 (31) 90 DB, 73 WB / 66 DB, 59 WB 19 26 Specifications are subject to change without notice. © 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. SPECIFICATIONS: PLA-A24EA7 & PUY-A24NHA7(-BS) Fan Motor Full Load Amperage Fan Motor Output Airflow Rate Refrigerant Control Heat Exchanger Type Sound Pressure Level, Cooling1 Compressor Type Compressor Model Compressor Rated Load Amps Compressor Locked Rotor Amps Compressor Oil Type // Charge External Finish Color Base Pan Heater Unit Dimensions Package Dimensions Unit Weight Package Weight Outdoor Unit Operating Cooling Intake Air Temp (Maximum / Minimum) Temperature Range Refrigerant Type Charge Gas Pipe Size O.D. (Flared) Liquid Pipe Size O.D. (Flared) Piping Maximum Piping Length Maximum Height Difference Maximum Number of Bends A W CFM dB(A) A A oz. W: In. (mm) D: In. (mm) H: In. (mm) W: In. (mm) D: In. (mm) H: In. (mm) Lbs. (kg) Lbs. (kg) °F Lbs, oz In.(mm) In.(mm) Ft. (m) Ft. (m) 0.40 86 1,940 Electronic Expansion Valve Cross fin 47 INVERTER-driven twin rotary SNB172FWHM1 7 11 FV50S // 23 Ivory Munsell 3Y 7.8/1.1 n/a 37-13/32 (950) 13 + 1-3/16 (330 + 30) 37-1/8 (943) 40-15/16 17-11/16 40-11/16 151 (68) 176 (80) 115 DB / -40* DB R410A 7 lbs, 11 oz 5/8 (15.88) 3/8 (9.52) 225 (69) 100 (30) 15 Notes AHRI Rated Conditions (Rated data is determined at a fixed compressor speed) 1Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB *Wind baffles required to operate below 23°F DB in cooling mode. For PUY models, wind baffles can be utilized to extend the cooling operation range to -40F. Please refer to the wind baffle submittals to determine which baffles are required to meet the desired operation range. **System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures. SEACOAST PROTECTION · External Outer Panel: Phosphate coating + Acrylic-Enamel coating · Fan Motor Support: Epoxy resin coating (at edge face) · Separator Assembly; Valve Bed: Epoxy resin coating (at edge face) · "Blue Fin" treatment is an anti-corrosion treatment that is applied to the condenser coil to protect it against airborne contaminants. Specifications are subject to change without notice. © 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. ACCESSORIES: PLA-A24EA7 High-efficiency Filter Element PAC-SH59KF-E Wireless Remote Receiver PAR-FA32MA-W Wireless Remote Receiver PAR-FA32MA-E Signal Receiver PAR-SR3LA-E kumo touchTM RedLINKTM Wireless Controller MHK2 Deluxe MA Remote Controller PAR-40MAAU Simple MA Controller PAC-YT53CRAU-J Touch MA Controller PAR-CT01MAU-SB Wired Remote Sensor PAC-SE41TS-E Lockdown Bracket for Wireless, Hand-held, Remote Controller RCMKP1CB Wireless Temperature and Humidity Sensor PAC-USWHS003-TH-1 Flush Mount Remote Temperature Sensor PAC-USSEN001-FM-1 Wireless Interface 2 PAC-USWHS002-WF-2 Thermostat Interface PAC-US444CN-1 kumo station® PAC-WHS01HC-E USNAP Interface PAC-WHS01UP-E IT Extender PAC-WHS01IE-E BACnet® and MODBUS® Interface PAC-UKPRC001-CN-1 External Fan / Heater Control Relay Adapter CN24RELAY-KIT-CM3 Connector for CN32 (remote on/off) PAC-SE55RA-E Remote Operation Adapter (with wire terminals for remote ON/OFF and operation status/ error)1 PAC-SF40RM-E Grille (required) PLP-40EAEU Multi-Function Casement PAC-SJ41TM-E Installation/Trim Panels PLFY-ITP1 Space Panel PAC-SJ38AS-E Air Outlet Shutter Plate PAC-SJ37SP-E Blue Diamond Sensor Extension Cable--15 Ft. C13-103 MegaBlue Advanced Blue Diamond Condensate Pump w/ Reservoir & Sensor X87-835 - 110 to 250V MaxiBlue Advanced Blue Diamond Mini Condensate Pump w/ Reservoir & Sensor (208/230V) up to 48,000 BTU/H X87-721 - 208/230V [recommended] 3 Pole Disconnect Switch (30A/600VUL) [fits 2"X4" utility] - Black TAZ-MS303 3 Pole Disconnect Switch (30A/600VUL) [fits 2"X4" utility] - White 1 Unable to use with wireless remote controller TAZ-MS303W Specifications are subject to change without notice. © 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. ACCESSORIES: PUY-A24NHA7(-BS) Twinning Distribution Pipe (50:50) Air Outlet Guide Front Wind Baffle Side Advanced Wind Baffle Rear Advanced Wind Baffle Drain Socket Centralized Drain Pan M-NET Converter M-NET Converter Control/Service Tool Hail Guard Condensing Unit Mounting Pad 24" x 42" x 3" Outdoor Unit Stand--12" High Outdoor Unit Stand--18" High Outdoor Unit Stand--24" High Heavy Duty Wall Mounting Bracket for Outdoor Units--Coated Steel Heavy Duty Wall Mounting Bracket for Outdoor Units--316 Series Stainless Steel 3/8" x 5/8" x 10' / 1/2" Lineset (Twin-Tube Insulation) 3/8" x 5/8" x 15' / 1/2" Lineset (Twin-Tube Insulation) 3/8" x 5/8" x 30' / 1/2" Lineset (Twin-Tube Insulation) 3/8" x 5/8" x 50' / 1/2" Lineset (Twin-Tube Insulation) 3/8" x 5/8" x 65' / 1/2" Lineset (Twin-Tube Insulation) 3/8" x 5/8" x 100' / 1/2" Lineset (Twin-Tube Insulation) MSDD-50TR-E PAC-SG59SG-E WB-PA5 WB-SD5 WB-RE5 PAC-SG61DS-E PAC-SG64DP-E PAC-SJ85MA-E PAC-SJ95MA-E PAC-SK52ST HG-A6 ULTRILITE2 QSMS1201M QSMS1801M QSMS2401M QSWB2000M-1 QSWBSS MPLS385812T-10 MPLS385812T-15 MPLS385812T-30 MPLS385812T-50 MPLS385812T-65 MPLS385812T-100 Specifications are subject to change without notice. © 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. 6 OUTLINES AND DIMENSIONS 120° DIMENSIONS: PLA-A24EA7 NOTE1.CHOOSE THE GRILLE AMONG THE DEDICATED GRILLES. 2.REINFORCE THE SUSPENSION BOLT FOR EARTHQUAKE-RESISTANCE AS NEEDED. 3.FOR THE SUSPENSION BOLT, USE M10 OR W3/8. (PROCURED AT THE LOCAL SITE.) 4.FOR DRAIN PIPE, USE VP-25(O.D. n1-1/4''( { 32) PVC TUBE). DRAIN PUMP INCLUSION. RAISE IS MAX 33-7/16''(850mm) FROM THE CEILING. 5.ELECTRICAL BOX MAY BE REMOVED FOR THE SERVICE PURPOSE. MAKE SURE TO SLACK THE ELECTRICAL WIRE LITTLE BIT FOR CONTROL/POWER WIRES CONNECTION. 6.THE HEIGHT OF THE INDOOR UNIT IS ABLE TO BE ADJUSTED WITH THE GRILLE ATTACHED. 7.REQUIRES "E" OR MORE SPACE BETWEEN TRANSOM AND CEILING FOR THE INSTALLATION. 8.WHEN INSTALLING THE BRANCH DUCTS, BE SURE TO INSULATE ADEQUATELY. OTHERWISE CONDENSATION AND DRIPPING MAY OCCUR. (IT BECOMES THE CAUSE OF DROPLET OR DROPLET DRIPPING.) 9.AS FOR NECESSARY INSTALLATION/SERVICE SPACE, PLEASE REFER TO THE RIGHT AT FIGURE. 10.FOR THE INSTALLATION OF THE OPTIONAL HIGH EFFICIENCY FILTER OR MULTI-FUNCTIONAL CASEMENT,REFER TO SPECIAL DRAWING. 1-7/16(37) (89) 3-1/2 OPTIONAL PART:SIGNAL RECEIVER 20(508) (AIR INTAKE HOLE) CORNER POCKET VANE MOTOR WALL CEILING GRILLE INDOOR UNIT OBSTACLE INDOOR UNIT BETWEEN THE TOP OF UNIT AND CEILING SLAB 118-1/8(3000mm) OR MORE BETWEEN INDOOR UNIT 70-7/8(1800mm) OR MORE FROM FLOOR F CEILING HEIGHT (1000mm) 39-3/8 OR MORE GRILLE 59-1/16(1500mm) OR MORE CEILING REMOTE CONTROLLER WIRE ENTRY FLOOR (20-45) 13/16 TO 1-3/4 REMOTE CONTROLLER WIRE ENTRY BRANCH DUCT HOLE (CEILING HOLE) 33-7/8 TO 35-13/16(860-910) 31-5/16 (795) (145) 5-11/16 (SUSPENSION BOLT PITCH) (145) 5-11/16 70° AIR INTAKE GRILLE REMOTE CONTROLLER TERMINAL BLOCK (20-45) 13/16 TO 1-3/4 FRESH AIR INTAKE HOLE (7mm) 1/4 OR MORE E SPACE IN THE CEILING (20) 13/16 (20-45) 13/16 TO 1-3/4 15-3/8(390) (100) 3-15/16 (90) 3-9/16 Unit: inch (mm) DETAILS OF FRESH AIR INTAKE HOLE {3-15/16({100) CUTOUT HOLE 120° {4-15/16({125) BURRING HOLE PITCH SELF-TAP 4 SCREWS:3 PLACES 6-1/4 (158) CEILING (167) 6-9/16 (155) 6-1/8 70° CEILING GRILLE {6-7/8({175) BURRING HOLE PITCH SELF-TAP 4 SCREWS:4 PLACES (CONNECTING TO BRANCH DUCT) {5-7/8({150) CUTOUT HOLE (CONNECTING TO BRANCH DUCT) 17-11/16(450) (350) 13-3/4 33-7/8 TO 35-13/16(860-910) (CEILING HOLE) +1-9/16 0 26 (660+040) (SUSPENSION BOLT PITCH) 33-1/16(840) 20(508) (AIR INTAKE HOLE) 37-3/8(950) 20-7/8(530) (AIR OUTLET HOLE) (100) 3-15/16 BRANCH DUCT HOLE INDOOR UNIT/ OUTDOOR UNIT CONNECTING TERMINAL BLOCK BRANCH DUCT HOLE (90) 3-9/16 (133) 5-1/4 (20) 13/16 1-7/16 3-1/2 (89) DRAIN HOLE (37) COMPANY NAME (AIR OUTLET HOLE) 20-7/8(530) 37-3/8(950) AUTO VANE I-SEE SENSOR CORNER PANEL SOME GRILLES DO NOT HAVE THIS PART. *CAN INSTALL TO THE CORNER EXCEPT DRAIN PIPE CORNER (NEED TO FUNCTION SETTING BY REMOTE CONTROLLER) {5-7/8({150) CUTOUT HOLE (CONNECTING TO BRANCH DUCT) {6-7/8({175) BURRING HOLE PITCH SELF-TAP 4 SCREWS:4 PLACES (CONNECTING TO BRANCH DUCT) (193) 7-5/8 (222) 8-3/4 BRANCH DUCT HOLE 33-1/16(840) SUSPENSION BOLT M10 OR W3/8 (60) 2-3/8 MAIN UNIT 24-3/4(628) PLA-A.EA7*:12/18/24/30/36/42 2 MODELS REFRIGERANT PIPE6.35 FLARED CONNECTION 1/4F REFRIGERANT PIPE9.52 FLARED CONNECTION 3/8F REFRIGERANT PIPE{12.7 FLARED CONNECTION 1/2F REFRIGERANT PIPE{15.88 FLARED CONNECTION 5/8F A B 9-1/2 10-3/16 (241) (258) 11-1/16 11-3/4 (281) (298) CD E 3(76) 3(76.5) 10-7/16(265) OR MORE 3-1/8 12(305) (79.5) OR MORE F 137-13/16(3500) OR LESS 177-3/16(4500) OR LESS DETAILS OF SIGNAL RECEVER EMERGENCY OPERATION SWITCH <COOLING>AND EMERGENCY UP/DOWN SWITCH<UP> RECEIVER OPERATION LAMP EMERGENCY OPERATION SWITCH <HEATING>AND EMERGENCY UP/DOWN SWITCH<DOWN> DEFROST/STAND BY LAMP (170) 6-11/16 (140) 5-1/2 1 THE BOTTOM OF I-SEE SENSOR SUSPENSION BOLT LOWER EDGE INDOOR UNIT/OUTDOOR UNIT CONNECTING WIRE, POWER SUPPLY WIRE ENTRY (145) 5-11/16 DRAIN PIPE VP-25 CONNECTION (CONNECTED THE ATTACED DRAIN SOCKET) GRILLE CEILING 1/4(6) 5-11/16(145) 4-1/8 (105) 3-1/8(79.5) D C (17+05) 11/16 +3/16 0 (190) 7-1/2 A B 1-9/16 (40) (20-45) 13/16 TO 1-3/4 (100) 3-15/16 (130) 5-1/8 SELF-TAP 4 SCREWS:14 PLACES (CONNECTING TO BRANCH DUCT) 13-3/4×3-15/16(350×100) CUTOUT HOLE (CONNECTING TO BRANCH DUCT) (50-70) 1-15/16 TO 2-3/4 2-5/16 (58) Specifications are subject to change without notice. © 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. PUZ-A24NHA7 PUZ-A24NHA7-BS OCH636 PUZ-A30NHA7 PUZ-A30NHA7-BS DIMENSIONS: PUY-A24NHA7(-BS) FREE Min. 500 <19-11/16> Min. 100 <3-15/16> Max. 30 <1-3/16> 1 FREE SPACE (Around the unit) The diagram below shows a basic example. Explantion of particular details are given in the installation manuals etc. 2 SERVICE SPACE Dimensions of space needed for service access are shown in the below diagram. Min. 10mm <3/8> Min. 500mm <19-11/16> Min. 10mm <3/8> Min.100mm <3-15/16> Min. 10 <13> Service space Min. 500 <19-11/16> Example of Notes Handle for moving 1 ... Refrigerant GAS pipe connection (FLARE) ø15.88(5/8F) 2 ... Refrigerant LIQUID pipe connection (FLARE) ø 9.52(3/8F) *1... Indication of STOP VALVE connection location. Air Intake 3 FOUNDATION BOLTS 4 PIPING-WIRING DIRECTIONS Please secure the unit firmly with 4 foundation (M10<W3/8>) bolts. (Bolts and washers must be purchased locally.) Piping and wiring connections can be made from 4 directions: FRONT,Right,Rear and Below. <Foundation bolt height> 175 <6-7/8> Side Air Intake Rear Air Intake 600<23-5/8> Installation Feet Unit: mm<in> 2-U Shaped notched holes (Foundfation Bolt M10<W3/8>) 175<6-7/8> 19 <3/4> 370<14-9/16> 417 <1-1/32> 330 <13> FOUNDATION Rear Air Intake Handle for moving 28<1-3/32> 25 <31/32> Air Discharge 70 <2-3/4> 57<2-1/4> 61<2-13/32> 40<19/32> 0 53<2-3/32> 41 <1-5/8> 2-12×36 oval holes (Foundation Bolt M10<W3/8>) Handle Side Air Intake for moving 950 <37-13/32> 322<12-11/16> Earth terminal LTeerftm..in. aPloCwoenrnseucptpiolynswiring Reight ... Indoor/Outdoor wiring Service panel Handle for moving 1 2 *1 431<16-31/32> *1 447<17-5/8> 669<26-11/32> 943 <37-1/8> 473 <18-5/8> 23 <29/32> Piping knockout Hole Details Power supply wiring hole (2-ø27knockout) Front trunking hole 40<1-9/16> (knockout) 45 <1-25/32> Right piping hole (knockout) 75 <2-31/32> Power supply wiring hole (2- ø27knockout) Right trunking hole (knockout) 40<1-9/16> 45<1-25/32> 73 <2-7/18> 63 <2-1/2> 55 <2-3/16> 63 <2-1/2> 63<2-1/2> 55<2-3/16> 73 <2-7/8> Front piping hole (knockout) <3ø-952/8> 92<3-5/8> 65 <2-9/16> 19<3/4> ø 92 <3-5/8> 92 <3-5/8> 55 <2-3/16> Power supply wiring hole (2- ø27<1-1/16>knockout) 40<1-9/16> Rear trunking hole (knockout) ø92 <3-5/8> Rear piping hole (knockout) 92 <3-5/18> 65 <2-9/16> Set the attachment to the When installing the conduit, inner side of each panel. 1/2 Conduit attachment 2-ø22.2<7/8> 40<1-9/16> 74<2-19/32> 31<1-7/32> 71 <2-13/16> 71<2-13/16> Front piping cover Rear piping cover Bottom piping hole (knockout) 219 <8-5/8> 81<3-3/16> 30 <1-3/16> 220 145 145 145 <8-21/32> <5-23/32><5-23/32><5-23/32> Drain hole (5- ø33<1-5/16>) 15 PUY-A24NHA7 PUY-A24NHA7-BS 27 23 <29/32> <1-1/16> 92 <3-5/8> 23 <29/32> 27<1-1/16> 73 <2-7/18> 27<1-1/16> 23 <29/32> PUY-A30NHA7 PUY-A30NHA7-BS FORM# PLA-A24EA7 / PUY-A24NHA7(-BS) - 202003 Specifications are subject to change without notice. 1340 Satellite Boulevard, Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com © 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.AH XSL Formatter V6.6 R1 for Linux64 : 6.6.1.34539 (2018/08/29 13:12JST) Antenna House PDF Output Library 6.6.1307 (Linux64)