SFA Sanidouche Flat Installation Guide

This document provides installation instructions for the SFA Sanidouche Flat macerator pump.

Product Overview

The Sanidouche Flat is a compact macerator pump designed for low-profile shower installations. It allows for the installation of a shower in locations where traditional gravity drainage is not possible.

Technical Specifications

Model: SANIDOUCHE® FLAT / SANISHOWER® FLAT

Standard: EN 12050-2

Model Designation: D60

Electrical: 220-240V - 50Hz - 250 W

Protection: IP44

Current: 1.3A

Weight: 3.7 kg

Installation Diagrams and Descriptions

General Layout

The system comprises a shower tray, a waste trap, the Sanidouche Flat unit, and discharge pipework. The Sanidouche unit receives wastewater from the shower and other connected appliances (e.g., basin) and pumps it to the main sewage line.

Diagram showing a shower tray and basin draining into the Sanidouche unit, which then pumps wastewater horizontally and vertically.

Pipework Recommendations

Discharge Pipe Diameter: Recommended Ø 32 mm / Ø 40 mm.

Maximum Vertical Lift: 3 meters.

Maximum Horizontal Run: 10 meters for Ø 32 mm pipe, 20 meters for Ø 40 mm pipe.

Gradient: A minimum gradient of 1% is recommended for horizontal pipe runs.

Diagram illustrating recommended pipe diameters, maximum vertical lift, and horizontal run lengths with corresponding gradients.

Installation Steps Overview

  1. Inlet Connections: Connect the shower waste trap and any other inlets to the Sanidouche unit using appropriate pipework and connectors. Ensure correct pipe routing to avoid kinks and allow for gravity flow to the unit.
  2. Discharge Pipe Connection: Connect the discharge pipe to the Sanidouche unit's outlet. Use the provided connectors and ensure a secure fit.
  3. Electrical Connection: Ensure the unit is connected to a suitable power supply as per local regulations.
  4. Mounting: The unit should be installed in a well-ventilated area, typically below the shower tray, and secured to prevent movement.

Component Identification

The following components are typically included or required for installation:

Diagram showing various components including the macerator unit, different types of waste traps, connectors, clamps, and tools.

Detailed Installation Steps

  1. Step 1: Prepare Inlet Connections

    Connect the shower waste trap to the Sanidouche unit using the appropriate Ø 22 mm or Ø 32 mm inlet adapter and clamp (C).

    Diagram showing the connection of a waste trap to the Sanidouche unit with Ø 22mm and Ø 32mm options.

  2. Step 2: Connect Discharge Pipe

    Attach the discharge pipe to the outlet of the Sanidouche unit using connector (E) and clamp (D).

    Diagram illustrating the connection of the discharge pipe with a flexible connector and clamp.

  3. Step 3: Install Waste Trap

    The waste trap should be installed in the shower tray, ensuring a watertight seal. The height of the trap connection to the Sanidouche unit is approximately 42 mm.

    Cross-section view of the waste trap installed in a shower tray.

  4. Step 4: Route Discharge Pipework

    Route the discharge pipe to the main sewage line, maintaining the recommended gradient. Avoid sharp bends.

    Diagram showing the routing of the discharge pipe with recommended gradients.

  5. Step 5: Secure Unit and Pipework

    Ensure the Sanidouche unit is securely placed and the pipework is adequately supported.

  6. Step 6: Connect Ø 40 mm Discharge Pipe

    Use connector (F) and clamp (E) for a Ø 40 mm discharge pipe.

    Diagram showing the connection of a Ø 40 mm discharge pipe.

  7. Step 7: Connect Ø 32 mm Discharge Pipe

    Use connector (F) and clamp (E) for a Ø 32 mm discharge pipe.

    Diagram showing the connection of a Ø 32 mm discharge pipe.

  8. Step 8: Electrical Grounding

    Connect the grounding wires (G) using screws (H) to the designated terminals on the unit.

    Diagram illustrating the electrical grounding connection points.

  9. Step 9: Final Assembly Check

    Ensure all connections are secure and all components are correctly installed.

    Diagram showing the final assembly with tools used for tightening.

Performance Curve

The graph shows the flow rate (L/min) versus the head (meters) for the Sanidouche Flat, indicating its performance characteristics according to EN 12050-2.

Performance curve graph showing flow rate vs. head.

Dimensions

Detailed diagrams provide the overall dimensions of the Sanidouche Flat unit.

Front and side views of the Sanidouche Flat unit with key dimensions labeled.

Company Contact Information

France

SOCIÉTÉ FRANÇAISE D'ASSAINISSEMENT
41 bis avenue Bosquet - 75007 Paris
Tel. +33144823900
Fax +33144823901

United Kingdom

SANIFLO Ltd.,
Howard House, The Runway South Ruslip Middx., HA4 6 SE
Tel. +442088420033
Fax +442088421671

Ireland

SANIRISH Ltd
IDA Industrial Estate
Edendamy - County Offaly
Tel. +353469733102
Fax +353469733093

Australia

SANIFLO (Australasia) Pty Ltd
Unit 9/10, 25 Gbbes Street Chatswood NSW 2067
Tel. +61298826200
Fax +61298826950

Deutschland

SFA SANIBROY GmbH
Waldstr. 23 Geb. B5 - 63128 Dietzenbach
Tel. (060 74) 30928-0
Fax (060 74) 30928-90

Italia

SFA ITALIA spa
Via del Benessere, 9
27010 Siziano (PV)
Tel. 03826181
Fax 0382618200

Espana

SFA S.L.
C/ Vinyalets, 1 - P.I. Can Vinyalets 08130 Sta. - Perpètua de Mogoda Barcelona
Tel. +34935446076
Fax +34934621896

Portugal

SFA, Lda.
Sintra Business Park, ed.01- 1*P2710-089 SINTRA
Tel. +35219112785
Fax +35219577000

POCCHR

SFA POCCHR
101000 Moczków - Komarowski nępeynoæ 9a
Ten. (495) 2582951
@axc. (495) 2582951

SHISSE SCHWEIZ SVIZZERA

SFA SANIBROY AG
Vorstadt 4
3380 Wangen a. A.
Tel. +41 (0)326310474
Fax +41 (0)326310475

BENELUX

SFA BENELUX B.V.
Voltaweg 4
6101 XK Echt (NL)
Tel. +31475487100
Fax +31475486515

SVERIGE

SANIFLO AB
BOX 797
S-191 27 Sollentuna
Tel. +46 (0)8-404 1530
info@saniflo.se

POLSKA

SFA POLAND Sp. z 0.0.
ul. Kolejowa 33
05-092 Łomianki/Wanzawa
Tel. (+4822) 7320032
Fax (+4822) 7513516

SEERIA SECOND N.A.

SFA-SANIBROY, spol. s r.o
Na Košince Cex. 681- 18000 PRAHAB Libeń
Tel. +420266712855
Fax. +420266712856

ROMANA

SFA SANIFLO S.R.L.
Strada Leonard Nicolae, nr. 2A
Timişoara 300454
Tel. +40256245092
Fax +40256245029

TURKIYE

SFA SANIHYDRO LTD STI
Mecidiye Cad No:36-B Sevencan APT 34394 MECIDIYEKDY - ISTANBUL
Tel. +902122753088
Fax. +902122759058

CHINA

SFA 中国
上海市静安区石门二路333弄3号振安广场恒安大厦27C (200041 )
Tel. +86(0)2162188969
Fax. +86(0)2162188970

KORRA

www.SFA.biz
sales@saniflo-korea.kr

South Africa

SFA Africa
www.saniflo.co.za

BRAZIL

SANITRIT
Rua Manuel da Nobrega 354Paraiso CEP 04001-0015AO PAULO / SP
Tel. + 551132622903
www.sanitrit.com.br

Service Helplines

Country Tel Fax
France 03810 0530 02 0344944619
United Kingdom 08457650011 (Call from a land line) 02088421671
Ireland 1850232425 (LOW CALL) +353469733093
Australia +1300554779 +61.2.9882.6950
Deutschland 08008227820 (060 74) 30928-90
Italia 03826181 +390382618200
España +34935446076 +34934621896
Portugal +35219112785 +35219577000
Suisse Schweiz Svizzera +41 (0)326310474 +41 (0)326310475
Benelux +31475487100 +31475486515
Sverige +46 (0)8-404 1530
Norge +46 (0)8-404 1530
Polska (+4822) 7320033
POCCHR (495) 2582951
Česká Republika +420266712855
România +40256245092
Türkiye +902122753088
中国 +86(0)2162188969
Brazil +551132622903 +31475486515

For service information, visit: www.sta.fr

Models: Douche Flat, Shower Flat

File Info : application/pdf, 6 Pages, 884.39KB

PDF preview unavailable. Download the PDF instead.

original

References

GPL Ghostscript 9.26 Adobe InDesign CS6 (Windows)

Related Documents

Preview SFA Sanidouche, Sanishower, Sanipump Installation Guide
Comprehensive installation instructions and technical specifications for SFA Sanidouche, Sanishower, and Sanipump macerator pumps. Includes diagrams, part lists, and contact information for global service.
Preview SFA Sanidouche/Sanishower/Sanipump Installation and User Manual
Comprehensive guide for installing and using SFA Sanidouche, Sanishower, and Sanipump wastewater lifting stations. Includes safety, applications, maintenance, troubleshooting, and technical specifications.
Preview SFA Sanidouche, Sanishower, Sanipump Installation and User Manual
Comprehensive guide for the installation, operation, maintenance, and troubleshooting of SFA Sanidouche, Sanishower, and Sanipump wastewater lifting stations. Covers product features, safety instructions, and technical specifications.
Preview Guide d'installation SFA SANIDOUCHE, SANISHOWER, SANIPUMP
Ce manuel fournit des instructions complètes pour l'installation, l'utilisation et la maintenance des stations de relevage SFA SANIDOUCHE, SANISHOWER et SANIPUMP. Il détaille les applications, les raccordements électriques, les procédures de dépannage et les conditions de garantie, assurant une performance optimale et sécurisée.
Preview SANIPACK/SANINSIDE Macerator Pump Installation and Maintenance Manual
This manual provides comprehensive instructions for the installation, operation, maintenance, and troubleshooting of SANIPACK/SANINSIDE compact lift pumps. Designed for efficient waste water removal from horizontal outlet toilets, showers, bidets, and washbasins, these SFA macerator pumps ensure reliable performance when installed and used correctly.
Preview SFA Sanivite/Sanipump 2 Installation and Operation Manual
This document provides installation instructions, technical specifications, and contact information for the SFA Sanivite/Sanipump 2 macerator pump.
Preview SFA SANIBEST® PRO B85 Installation and Maintenance Manual
This document provides comprehensive installation, operation, and maintenance instructions for the SFA SANIBEST® PRO B85 macerator pump. It covers safety precautions, applications, installation steps, electrical connections, troubleshooting, and warranty information.
Preview SFA SANIPACK/SANINSIDE Installation and User Manual
Comprehensive installation, operation, maintenance, and troubleshooting guide for the SFA SANIPACK/SANINSIDE macerator pump unit, designed for efficient wastewater removal. Includes technical specifications and warranty information.