Corelite Divide - DWI
WaveStream™ LED Wall Mounted Direct / Indirect
Typical Applications: Office, Education, Healthcare, Hospitality, Retail
Top Product Features
- Available in 2', 4', 8', and Continuous runs
- Leverages patented WaveStream™ Technology with AccuAim™ optics
- Advanced optical control with asymmetric throw
- Modern, ultra-shallow design
Dimensions and Fixture Lengths
Housing dimensions: 2.75" [70mm] height, 10.0" [254mm] width.
Fixture Lengths: 24" [610mm], 48" [1219mm], 96" [2438mm]
WaveStream Accu-Aim Optic Patterns
WA - Specular, Asymmetric
WD - Diffuse, Asymmetric
Order Information
Series | Shielding | Lumen Package Nominal per 4' section | CRI | Color Temperature | Number of Circuits | Additional Circuiting | Input Voltage | Notes |
---|---|---|---|---|---|---|---|---|
DWI=Divide Wall Direct/Indirect | WA=WaveStream Specular Optic, Asymmetric WD=WaveStream Diffuse Optic, Asymmetric |
15L=1,500 Lms (375 lms/ft) 25L=2,500 Lms (625 lms/ft) 30L=3,000 Lms (750 lms/ft) 40L=4,000 Lms (1000 lms/ft) 50L=5,000 Lms (1250 lms/ft) 65L=6,500 Lms (1625 lms/ft) |
8=80+CRI 9=90+CRI |
30=3000K, 80CRI 35=3500K, 80CRI 40=4000K, 80CRI |
1=Single Circuit | D=None (Default Dimming) E=Emergency Circuit S=Secondary Circuit N=Emergency + Secondary Circuit |
120=120V 277=277V UNV=Universal (120V-277V) 347=347V |
Refer to performance table on page 3 for more detail. Additional lead-time may apply for 930, 935, and 940 configurations. Refers to wiring in cross section. Secondary circuit not available with integrated sensor options. 347V available with STD 0-10V driver option. 347V not available with 15L and 25L lumen packages in 2' unit length. |
Product Specifications
Construction
2-3/4" x 10" housing constructed of extruded aluminum and die-formed, code gauge cold rolled steel.
End Caps
Precision engineered die cast end caps. Attach mechanically without exposed fasteners. Adds 1/2" at each end.
Lengths
Available in 2-ft, 4-ft, and 8-ft sections. Modular design eliminates need for starter, joiner, and end sections. See Standard Row Configurations table for continuous row length breakdowns.
Finish
Electrostatically applied polyester powder coat paint in white, silver, or black. RAL custom colors available.
Mounting
Mounts directly to structure over a 2"x 4" standard electrical box mounted horizontally into the wall. Continuously wired with push-in connectors. Fixtures can be joined for straight continuous runs. Refer to installation instructions for details.
Shielding / Optics
Optical grade acrylic with patented AccuAim™ micro-optics for optimal distribution, low glare, and high performance. Available in Specular (WS) or Diffuse (WD) optical patterns. Options include Dust Cover (DC - clear polycarbonate), Frosted Cover (FC - frosted polycarbonate), and Solid Cover (SC - white powder coat steel reflector for 100% downlight).
LED and Light Engine
LEDs available in 3000K, 3500K, 4000K. Lumen output is affected by CCT; refer to lumen adjustment factor table. LED system coupled with integral electronic drivers. 347V 0-10V drivers available. Dimming wires included.
Integrated Controls
0-10V dimming to 1% standard. Compatible with WaveLinx, Enlighted, and WaveLinx Lite sensors for IoT capability.
Emergency Options
Optional 120V-277V integral emergency battery pack (14W maximum, 90-minute output) powers a 4-foot section. Test switch/indicator button on top of luminaire. Patented EZ Key prevents accidental battery discharge. Consult factory for emergency section wiring and generator transfer options.
Weight
3.5 lbs per foot.
Compliance
cULus listed for damp locations (25°C ambient). RoHS compliant. Tested to IESNA LM-79 and LM-80. Stated life per TM21 standards.
Warranty
Five year warranty standard. Visit www.cooperlighting.com/legal for details.
Photometric Data
DWI-WA-40L835-1D-UNV-4.IES: Lamp: (LD2) LED 3500K, Lumens: 3952 Lm, Watts: 31.8 W, Efficacy: 124 Lm/W, Test No.: ITL89479, Distribution: 45% UP / 55% DOWN.
DWI-WD-40L835-1D-UNV-4.IES: Lamp: (LD2) LED 3500K, Lumens: 4021 Lm, Watts: 31.8 W, Efficacy: 126 Lm/W, Test No.: ITL89479, Distribution: 46% UP / 54% DOWN.
Energy and Performance Data
Divide Wall LED Light Level Outputs and Distributions (3500K, 80 CRI)
Series | Lumen Package | Delivered Lumens | Wattage | Efficacy LPW | Distribution | |||
---|---|---|---|---|---|---|---|---|
4FT | Per FT | 4FT | Per FT | % Up | % Down | |||
15L | 1473 | 368 | 11.5 | 2.9 | 128 | 45% | 55% | |
25L | 2476 | 619 | 19.0 | 4.8 | 130 | |||
30L | 2974 | 744 | 23.1 | 5.8 | 129 | |||
DWI-WA | 40L | 3952 | 988 | 31.8 | 8.0 | 124 | ||
50L | 4897 | 1224 | 41.3 | 10.3 | 119 | |||
65L | 6243 | 1561 | 57.1 | 14.3 | 109 | |||
15L | 1499 | 375 | 11.5 | 2.9 | 130 | |||
25L | 2519 | 630 | 19 | 4.8 | 133 | |||
30L | 3026 | 757 | 23.1 | 5.8 | 131 | |||
DWI-WD | 40L | 4021 | 1005 | 31.8 | 8.0 | 126 | 46% | 54% |
50L | 4983 | 1246 | 41.3 | 10.3 | 121 | |||
65L | 6352 | 1588 | 57.1 | 14.3 | 111 |
Lumen Adjustment Factors
CCT | 80 CRI | 90 CRI |
---|---|---|
3000K | 0.955 | 0.830 |
3500K | 1.000 | 0.861 |
4000K | 1.012 | 0.883 |
Example Calculation: For WA/40L/3500K/80CRI, a 988 lms/ft output with a 0.861 adjustment factor yields 851 lms/ft.
Color Data (3500K)
TM-30-15 (80CRI): Rf 82.3, Rg 94.4. CRI/CIE: Ra 84.0, R9 17.2.
Lumen Maintenance
At 25°C ambient temperature, TM-21 Lumen Maintenance (60,000 hours) is >85%. Theoretical L70 is 154,000 hours.
Standard Row Configurations
Fixture Length | 2' | 4' | 6' | 8' | 10' | 12' | 14' | 16' | 18' | 20' | 22' | 24' | 26' | 28' | 30' | 32' | 34' | 36' | 38' | 40' | 42' | 44' | 46' | 48' |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
2' | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | ||||||||||||
4' | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | ||||||||||||
8' | 1 | 1 | 1 | 1 | 2 | 2 | 2 | 2 | 3 | 3 | 3 | 3 | 4 | 4 | 4 | 4 | 5 | 5 | 5 | 5 | 6 |
Control Systems
- WaveLinx Wireless
- WaveLinx Wired
- WaveLinx Lite
- Enlighted
- iLumin Plus
- VividTune
Sensor Integration
Integrated sensors are located in the middle of each 8' section and on the end of 4' sections for individual and continuous runs. Each section can be individually controlled or grouped together with the integrated sensors.
Systems Comparison Chart
Standalone | Controlled WaveLinx Lite | Connected WaveLinx Wireless | Enterprise Trellix | |
---|---|---|---|---|
Occupancy | Yes | Yes | Yes | Yes |
Daylighting | Yes | Yes | Yes | Yes |
Gateways | - | 1 WAC | 300 WACS | 300 WACS |
Devices | 50 per Area (1400 per site) | 150 per WAC | 45,000 per Core Enterprise | 45,000 per Core Enterprise |
Software | WaveLinx Lite Mobile App | WaveLinx Mobile App | Trellix Core | Trellix Core |
Areas | 28 per Site | 16 per WAC | up to 4,800 | up to 4,800 |
Zones | 16 per Area | 16 per Area | up to 76,800 | up to 76,800 |
Scheduling | Installer | Local | Global | Global |
VividTune™ | - | Yes | Yes | Yes |
Plug-Load Control | - | Yes | Yes | Yes |
Integration | - | - | BACnet, API | BACnet, API |
Dashboards | - | Energy, Occupancy | Energy, Occupancy | Energy, Occupancy |
Configuration | Installer | Technician | Technician / IT | Technician / IT |
The Divide with Integrated Sensor technology provides automatic energy savings. WaveLinx Lite offers out-of-the-box functionality for standalone and controlled applications. WaveLinx Wireless, combined with Trellix, offers a connected lighting system for enhanced connectivity, energy savings, and data aggregation.
Scalability graphic illustrates progression from Devices to Areas, Floors, and Buildings.