Corelite Continua™ SQ4R
LED Recessed Direct Luminaire
Typical Applications
- Office
- Education
- Healthcare
- Hospitality
- Retail
Top Product Features
- Nominal 4" linear aperture
- Available in 4' and 8' lengths for individual or continuous runs
- Seamless illumination with continuous roll lens
- Seamless Batwing or Asymmetric lens option available
- Perceive™ Technology: 5 differentiated lens aesthetics - PARAmid, Prism, Waves, Ripple and Honeycomb
- Integration with 6 common architectural ceiling types
- Multiple lumen packages
- 3000K, 3500K and 4000K CCT at 80+ or 90+ CRI
- Available with BioUp and VividTune tunable white technologies
- Integrated sensor systems - occupancy, daylight and IoT connectivity
Dimensions
Diagram Description: Two diagrams showing cross-sections of the luminaire for T-Grid and Gypsum installation. Dimensions are provided in inches and millimeters.
T-Grid Install: Shows a width of 4.625" [117.47 mm] and a depth of 4.506" [114.45 mm]. Cutout dimensions for the grid are shown as 3.3" [83.82 mm] to 5.0" [127 mm].
Gypsum Install: Shows a width of 4.625" [117.47 mm] and a depth of 4.250" [107.95 mm]. Cutout dimensions for gypsum board are shown as 3.3" [83.82 mm] to 4.25" [107.95 mm].
Product Specifications
Construction
- Formed housing with precision cut housing trim extruded from 6063 aluminum.
- Laser-cut formed cold rolled steel endcaps.
- Die-formed 22 gauge cold rolled steel pre-paint white reflector.
- Driver accessible from below.
Lengths
- 4 ft and 8 ft fully illuminated sections for individual and continuous runs.
- See table on page 6 for continuous row length breakdowns.
Finish
- Electrostatically applied polyester powder coat paint.
Mounting
- Recessed lay-in for T-grid installation or direct into gypsum with 1½" flange.
- Fixtures can be joined for straight continuous runs using rigid alignment features.
Shielding
- F: Frosted - Flush, high diffusion pixilation-free lens.
- FB: Frosted Batwing - Continuous flexible roll lens creates seamless illumination along entire row length. Single piece roll lens up to 100 ft.
- FA: Frosted Asymmetric - Continuous flexible roll lens creates seamless illumination along entire row length. Single piece roll lens up to 100 ft.
- PC3, PP3, PW1, PR1, PH1: Proprietary Perceive™ optical system - Provides dynamic visual depth on a flat surface while offering glare-reducing performance with comfortable, high-quality illumination. Perceive continuous flexible roll lens creates seamless illumination along entire row length. Single piece roll lens up to 100 ft.
Light Engine
- LEDs available in 2700K, 3000K, 3500K, 4000K.
- CRI options of either ≥80CRI or ≥90CRI.
- VividTune tunable white and BioUp light engines available.
- TM21 life at 60,000 hours up to L94 and calculated L70 exceeds 400,000 hrs.
- Drivers available in 120-277V and 347V.
Integrated Controls
- 0-10V dimming to 1% standard.
- WaveLinx wireless sensor compatible for standalone, controlled, connected, and IoT capability.
- DALI 2.0 and Lutron available.
Emergency Options
- Default emergency circuit section (E) is 4 ft. in length and located at the beginning of the fixture unless designated elsewhere.
- Optional 120-277V emergency battery provided internal to fixture with pre-wired external test switch.
- 90-minute backup period for code compliance.
- Estimated lumen output = battery wattage x min efficacy (e.g., 100 lm/W x 6W = 600 lumens).
- UL 924 emergency/generator transfer options available.
Weight
2.7 lbs. per foot.
Compliance
- cULus listed for damp locations.
- Meets NYC requirements.
- IC Rated for insulation contact (except where noted).
- Tested to IESNA LM-79 and LM-80.
- Stated life per TM21 standards.
- Can be used for State of California Title 24 high efficacy luminaire.
- Meets NEMA 77, California Title 24, and IEEE1789 low risk or less than 5% modulation depth at all frequency below 90Hz.
Warranty
- Five year limited warranty standard. Optional ten year limited warranty available.
Order Information
Sample Order Number: SQ4R-F-100D835-1D-UNV-STD-W-T1-16
Domestic Preferences | Series | Shielding | Lumen Package (Lms/ft) | CRI/CCT | Circuiting | Emergency |
---|---|---|---|---|---|---|
[Blank]=Standard BAA=Buy American Act |
SQ4R= SQ 4" Linear Recessed, Direct | F=Frosted Continuous Roll Lens FB= Batwing Frosted Continuous Roll Lens FA= Asymmetric Frosted Continuous Roll Lens |
050D=500 Lumens/ft Down 075D=750 Lumens/ft Down 100D=1000 Lumens/ft Down 125D=1250 Lumens/ft Down |
830-3000K, 80CRI 835-3500K, 80CRI 840-4000K, 80CRI 927-2700K, 90CRI 930-3000K, 90CRI 935-3500K, 90CRI 940-4000K, 90CRI 93050-White Tuning 3000K-5000K 92765-White Tuning 2700K-6500K B35= 3500K Static BioUp B40= 4000K Static BioUp B50= 5000K Static BioUp B2750= 2700K-5000K Dynamic BioUp |
1=Single Circuit S=Secondary Circuit _D=Specify ** |
E=Emergency Circuit BSL6=Bodine 6-watt, 120V-277V Emergency Battery Pack, BSL6LST EPC-LVS Controls EPC UL924 Bypass Relay Device |
Notes: Only product configurations with this designated prefix are built to be compliant with the Buy American Act of 1933 (BAA). Please refer to DOMESTIC PREFERENCES website for more information. Components shipped separately may be separately analyzed under domestic preference requirements. | Notes: All Continua SQ4 shielding lens options provide seamless illumination with continuous roll lenses up to 100 ft. | Notes: Custom lumen output available. Down (Direct): Min = 200 Lms/ft, Max = 1900 Lms/ft. Example: 135D = 1350 Lms/ft Down. **Consult factory to specify custom lumen package. Not all lumen packages are available for every configuration. See Driver Availability tables for more details. Refer to Driver Availability table on page 6 for BioUp light level availability. | Notes: White Tuning is 90CRI standard. Tunable White options to be used with W2A driver only. Must be used with two (2) 10V dimming control channels, 1 color, 1 intensity. Not compatible with other control or sensor options. 2700K may require additional leadtime, please consult factory. BioUp Static to be used with STD driver. BioUp white tuning provides correlated color temperatures (CCT) between 2700K (warm) to 5000K (cool). Must be used with W2A or W2D driver. BioUp technology CRI ranges from > 80 CRI to 96 CRI and is correlated to CCT. | Notes: Emergency and Secondary circuit section wiring are configured per unit (4ft, 8ft). Emergency circuit option operates entire portion of a specified unit. EPC option used to bypass local control during outage. Must be used in conjunction with UL 1008 device (provided by others). Battery operates entire portion of 4ft fixtures and 4ft sections of 8ft. Fixture Non-IC-Rated for internal battery and lumen output ≥1000 Lms/ft. |
Voltage | Driver/Dimming | Sensor Options | Options | Mounting | Run Length |
---|---|---|---|---|---|
UNV=Universal (120V-277V) 347=347V |
STD=Standard 0-10V (1%-100%) 5LT=Fifth Light DALI (1%-100%) LH=Lutron HiLume 1% EcoSystems (LDE1) W2A=2-Channel 0-10V (VividTune and Dynamic BioUp Only) W2D=2-Channel DALI (Dynamic BioUp Only) |
[Blank]=No Sensor WLS (formerly WAB)=WaveLinx LITE Wireless Sensor, Occupancy w/ photocell, Independent & Networked (B) WPS (formerly WAA)=WaveLinx PRO Wireless Sensor, Occupancy w/ photocell, Networked (A) WPST=WaveLinx PRO Tilemount Sensor, Occupancy w/ photocell, Networked WLST=WaveLinx LITE Tilemount Sensor, Occupancy w/ photocell, Independent & Networked |
Finish CP=Chicago Plenum W=White |
T1=15/16" T-Grid, 9/16" T-Grid T2= 9/16" Slot T-Grid, 9/16" Tegular T-Grid, 9/16" Interlude T-Grid FG=Flanged (Gypsum Board) |
4=4 ft 8=8 ft XX=Specify Run Length |
Notes: Integral 347V driver with STD 0-10V option only. | Notes: See Driver Availability tables for more details. Use standard 0-10V (STD) for Static BioUP (B35 | B40 | B50). 2-Channel 0-10V (W2A) available with Vivid Tune (V) and Dynamic BioUp (B2750) only. 2-Channel DALI (W2D) available with Dynamic BioUp (B2750) only. | Notes: WaveLinx sensors available with STD driver and W2A drivers. Standard configurations available with single circuit and operate intensity/brightness only. For W2A driver, CCT adjustment controlled elsewhere--consult factory for alternatives. Integrated sensor options available in individual fixtures and runs up to 16ft. Tile-mount required for sensor options with runs over 16ft. Integrated Sensors combined with Emergency Circuit require UL924 Bypass Relay per emergency fixture. Integrated sensor options must be used in conjunction with the associated system and may not be compatible with other options or accessories. Please refer to the following: (A) Consult WaveLinx PRO system pages for additional details and compatibility. (B) WaveLinx LITE devices are not currently compatible with the WaveLinx Wireless Area Controller. Consult WaveLinx LITE system pages for additional details and compatibility. | Notes: Meets CCEA requirements. CP not available with tilemount sensors. | Notes: Please refer to ceiling interface diagrams for additional detail and dimensions. | Notes: See 'Standard Row Configurations' table on Page 6 for continuous row length breakdowns. |
Ceiling Type
Extruded Trim Flange Details - Refer to submittal drawings for detailed flange information - for additional options consult factory.
Grid Ceiling Systems
Diagram Description: Multiple diagrams illustrating different T-grid ceiling types (9/16" Tee, 9/16" Slotted Tee, 9/16" Tegular, 9/16" Interlude) with cross-section and side views, showing fixture integration and dimensions.
Drywall Ceiling
Diagram Description: Diagram showing a drywall ceiling installation with a visible flange (FG), including ceiling cutout dimensions and side views.
GYP Length Table:
Nominal Length | K - Body | L - Cutout | F - Flange to Flange |
---|---|---|---|
4 ft. | 47.000 | 47.250 | 47.688 |
8 ft. | 95.000 | 95.250 | 95.688 |
XXX ft. | xxx ft. - 1" | xxx ft. - 0.75" | xxx ft. - 0.312" |
Note: Actual dimensions and cutout length varies from Nominal Length as shown in the GYP Length Table.
Continuous Lens
Description: A diagram illustrating the continuous lens feature, indicating no breaks in the lens up to 100 ft.
Perceive™ Shielding Options
Diagram Description: Visual representations of the five Perceive™ shielding options: PC3-W (PARAmid Lens, White Fixture Finish), PP3-W (Prism Lens, White Fixture Finish), PW1-W (Waves Lens, White Fixture Finish), PR1-W (Ripple Lens, White Fixture Finish), PH1-W (Honeycomb Lens, White Fixture Finish).
Photometric Data - Static White LED Technology
Diagram Description: Multiple polar photometric plots for different configurations (e.g., Frosted Lens, Perceive PARAmid, Perceive Waves, Perceive Asymmetric) showing light distribution, lumens, watts, efficacy, and test numbers. Each plot is labeled with the file name and key specifications like CCT/CRI.
Note: Refer to IES files for more product data.
Photometric Data
Lumen Maintenance
Ambient Temperature | TM-21 Lumen Maintenance (60,000 hours) | Theoretical L70 (Hours) |
---|---|---|
25°C | >84% | 121,000 |
Notes: (1) Supported by IES TM-21 standards. (2) Theoretical values represent estimations commonly used; however, refer to the IES position on LED Product Lifetime Prediction, IES PS-10-18, that explains proper use of IES TM-21 and LM-80.
Color Data (3500K)
80CRI | 90CRI | |
---|---|---|
TM-30-15 Rf | 84 | 89.7 |
Rg | 97.2 | 97.2 |
Rf' | 83.4 | 94.3 |
Rg' | 10.9 | 61.7 |
Run Configurations
Table showing the number of fixtures per run length for 4ft and 8ft configurations, with different CCT and CRI options.
Driver Availability
Tables detailing the quantity of drivers available for different lumen packages and configurations, including standard 0-10V, DALI, Lutron, and BioUp options.
Energy and Performance Data - Frosted Lens and Perceive™ Lenses
Continua SQ4R Performance (3500K, 80 CRI)
Shielding | Lumen Package | Lumens/ft | W/ft | Lm/W | UGR | Max Luminance |
---|---|---|---|---|---|---|
F | 050D | 507 | 4.7 | 107.4 | 22.8 | 6481 |
075D | 746 | 6.7 | 111.3 | 24.1 | 9528 | |
100D | 988 | 9.3 | 106.8 | 25.1 | 12618 | |
125D | 1248 | 12.4 | 100.9 | 25.9 | 15947 | |
PC3-W | 050D | 502 | 4.7 | 106.2 | 22.2 | 6591 |
075D | 738 | 6.7 | 110.1 | 23.5 | 9690 | |
PC3 | 100D | 977 | 9.3 | 105.6 | 24.5 | 12832 |
125D | 1235 | 12.4 | 99.8 | 25.3 | 16218 | |
PH1 | 050D | 462 | 4.7 | 97.8 | 23.4 | 6154 |
075D | 679 | 6.7 | 101.4 | 24.8 | 9047 | |
100D | 899 | 9.3 | 97.2 | 25.7 | 11983 | |
125D | 1137 | 12.4 | 91.9 | 26.6 | 15144 | |
PP3 | 050D | 497 | 4.7 | 105.2 | 23 | 6601 |
075D | 731 | 6.7 | 109.1 | 24.3 | 9702 | |
PP3-W | 100D | 968 | 9.3 | 104.6 | 25.3 | 12850 |
125D | 1223 | 12.4 | 98.8 | 26.1 | 16241 | |
PR1 | 050D | 492 | 4.7 | 104.0 | 21.5 | 6844 |
075D | 723 | 6.7 | 107.9 | 22.8 | 10063 | |
100D | 957 | 9.3 | 103.5 | 23.8 | 13326 | |
125D | 1210 | 12.4 | 97.8 | 24.6 | 16842 | |
PW1 | 050D | 475 | 4.7 | 100.6 | 22 | 6780 |
075D | 699 | 6.7 | 104.3 | 23.4 | 9968 | |
PW1-W | 100D | 925 | 9.3 | 100.0 | 24.3 | 13201 |
125D | 1169 | 12.4 | 94.5 | 25.1 | 16685 |
Notes: (1) UGR values per CIE 190:2010 with 4H, 8H, Reflectance: 70% Ceiling, 50% Wall, 20% Ref. Plane. (2) For other UGR data for room or reflective ceiling plans please see technical data on website. (3) Luminance measured at 45-90 degrees from nadir. (4) UGR and Luminance values that meet WELL v2 L04 requirements for Managing Glare are shown with green highlighted cell. (UGR < 16, Luminance < 6,000, Indirect-only). (5) UGR and Luminance values that meet LEED v4.1 requirements for Glare Control are shown with green text. (UGR < 19, Luminance < 7,000, Indirect-only). (6) For technical data of other configurations please see photometric section on website or click link at top-right.
Lumen Adjustment Factors (non-BioUp)
CCT | 3000K | 3500K | 4000K | |||
---|---|---|---|---|---|---|
CRI | 80 | 90 | 80 | 90 | 80 | 90 |
Lumen Multiplier | 0.977 | 1.000 | 0.812 | 0.859 | 0.855 | 0.855 |
Melanopic Ratio | 0.483 | 0.558 | 0.654 | 0.584 | 0.673 | 0.744 |
Lumen Adjustment Factors (BioUp Static)
CCT | 3000K | 3500K | 4000K | 5000K | ||||
---|---|---|---|---|---|---|---|---|
CRI | 80+ | 90+ | 80+ | 90+ | 80+ | 90+ | 80+ | 90+ |
Lumen Multiplier | 0.956 | 0.803 | 1.000 | 0.852 | 0.988 | 0.888 | 0.969 | 0.955 |
BioUp Static | - | - | - | - | - | - | 0.934 | - |
Example Calculation: 025-075D / 3500K / 80 CRI. Lumen Output selected = 985 lm/ft. 3500K / 90 CRI Desired. Lumen Adjustment Factor = 0.852. Adjusted Lumen Output = 985 lm/ft x 0.852 = 839 lm/ft.
Control Solutions
The SQ4R with WaveLinx offers no-hassle lighting control with multiple luminaire level control solutions.
- WaveLinx LITE wireless
- WaveLinx PRO wireless
- WaveLinx CAT wired
- WaveLinx Wired
Integrated Sensor Coverage Pattern
Diagram Description: Top and side views illustrating the coverage pattern of integrated sensors, showing range in feet and meters for major motion and recommended mounting height.
Systems comparison chart
Cooper Lighting Solutions provides many lighting system solutions designed to satisfy code requirements and meet the unique needs of any project.
Luminaire with standalone sensor | Standalone Spaces WaveLinx LITE | Standalone Spaces WaveLinx CAT | Networked Spaces WaveLinx PRO | Enterprise WaveLinx CORE | |
---|---|---|---|---|---|
Occupancy | Yes | Yes | Yes | Yes | Yes |
Daylighting | Yes | Yes | Yes | Yes | Yes |
Wallstations | - | Yes | Yes | Yes | Yes |
Gateways | - | 1 WAC | 1 WAC | 300 WACs | 300 WACs |
Devices (MAX) | 40 per Area (1120 per space) | 40 per Area | 200 per WAC2 | 32,500 per CORE Enterprise | |
Software | - | WaveLinx LITE Mobile App | WaveLinx CAT Mobile App | WaveLinx Mobile App | CORE |
Areas | - | 28 per Space | Unlimited | 50 per WAC2 | up to 3,000 |
Zones | - | 16 per Area | 16 per Area | 16 per Area | up to 9,000 |
Scheduling | - | Local | Local | Global | Global |
Vivid Tune™ | - | Yes | Yes | Yes | Yes |
Plug-Load Control | - | Yes | Yes | Yes | Yes |
Low-Voltage Power | - | Yes | Yes | Yes | Yes |
Integration | - | - | - | BACnet, API | BACnet, API |
Dashboards | - | Installer | Installer | Technician | Technician / IT |
Configuration | - | Installer | Installer | Technician | Technician / IT |
SCALABILITY: WaveLinx expands from a single standalone device up to Enterprise with 32,500 devices.
*Note: WaveLinx LITE devices can be upgraded to WaveLinx PRO via an OTA firmware update. The OTA and system configuration can only be performed by Cooper Lighting Solutions specialists. WaveLinx Area Controller(s) would also need to be added to complete the solution.
Integrated Sensor Details and Placement
Sensor Type | Wireless | Sensor Integration | Ordering Code |
---|---|---|---|
WaveLinx | Yes | Integral to Fixture (End Cap) or Tile Mount | WPS/WLS WPST/WLST |
Standard Sensor with Luminaire Control
INTEGRAL SENSOR LAYOUT EXAMPLES
Diagram Description: Layout examples for integrated sensors in 4ft Individual, 8ft Individual, 16ft Run, and 20ft(+) Run configurations. Diagrams show sensor placement within the luminaire or tile mount.
VividTune™ color tuning solutions
SQ4R with VividTune Tunable White
VividTune tunable white luminaires from Cooper Lighting Solutions deliver high-quality light in a broad range of continuously variable color temperatures and intensities. Create a dynamic environment by adjusting the ambient light warmer or cooler to influence mood, support the task at hand, or create a dramatic ambience. The ability to control correlated color temperature and intensity separately using simple controls is the next evolution of LED lighting for the commercial, educational, healthcare and hospitality space. The unparalleled flexibility and number of available lighting environments enable users to find the right light with tunable white.
CCT Multiplier
CCT | 90CRI 3000K-5000K | 90CRI 2700K-6500K | ||
---|---|---|---|---|
2700K | 0.954 | - | - | - |
3000K | 0.981 | 0.974 | - | - |
3500K | 1.000 | 0.997 | - | - |
4000K | 1.011 | 1.016 | - | - |
4500K | 1.018 | 1.032 | - | - |
5000K | 1.025 | 1.044 | - | - |
5700K | - | 1.058 | - | - |
6500K | - | - | - | 1.068 |
Example Calculation: 025U-075D / 3000K-5000K tuned to 3500K. Lumen Output selected = 1202 lm/ft. 90CRI 3000K-5000K tuned to 4000K. Lumen Adjustment Factor = 1.011. Adjusted Lumen Output = 1130 lm/ft x 1.011 = 1215 lm/ft.
Controlling Vivid Tune Tunable White
VividTune luminaires make tunable white more accessible by using simple and familiar controls. From wall dimmers to wireless controls, VividTune tunable white luminaires are compatible with industry standard 0-10V dimming controls. A single 0-10V dimming input is used to control intensity (brightness) while a second 0-10V dimming input is used to adjust CCT. For suggested control configurations, go to www.cooperlighting.com for tunable white application guides.
Diagram Description: A color temperature and intensity control diagram showing the relationship between 0-10V dimming inputs for intensity and CCT, with a color spectrum from warm 2700K to cool 6500K.
BioUp™
Proven Research. Industry Recognized.
Melanopic Lighting
Diagram Description: Icons representing 'See better', 'Feel better', 'Function better'. A diagram showing "Brighter BloUp Days" and "Darker Nights". A link to the BioUp brochure is provided.
Illuminating ANSI/IES RP-46-23: This standard, published March 2024, is based on over 40 years of research and emphasizes the importance of circadian clock synchronization for the body's efficient and appropriate functioning.
INTERNATIONAL WELL BUILDING INSTITUTE™: BioUp solutions maximize WELL points for Circadian Lighting Design (L03). By using BioUp, equivalent Melanopic Lux (EML) thresholds for circadian design can be achieved, earning nearly 20% of WELL building lighting points.
MDER, M-EDI and EML are key metrics used to quantify non-visual performance of indoor lighting systems.
Diagram Description: Comparison of standard 4000K LED (MDER = .62) and BioUp 4000K LED (MDER = .82) with spectral distribution graphs showing melanopic and visual components.
30% boost Biological impact compared to traditional LED sources
CCT | LED MDER ~83 CRI | BioUp Static MDER CRI | BioUp Dynamic MDER CRI | ||||||
---|---|---|---|---|---|---|---|---|---|
MDER | CRI | MDER | CRI | MDER | CRI | ||||
2700K | 0.44 | - | 0.43 | - | - | 95 | |||
3000K | 0.49 | - | 0.54 | - | - | 94 | |||
3500K | 0.56 | - | 0.71 | - | - | 90 | |||
4000K | 0.64 | - | 0.84 | - | 0.71 | 90 | |||
5000K | 0.77 | - | 0.98 | - | 0.82 | 87 |
MDER - Melanopic Daylight Efficacy Ratio (MDER) measures the amount of light stimulating to the melanopsin receptors.
BioUp enhances the LED spectrum with cyan light at 475nm increasing the biological impact of the light to enhance our circadian rhythm which regulates our sleep/wake cycle, daytime engagement, and mood all without distorting visual color impression.
Diagram Description: Spectral distribution graphs for Static (non-tunable) and Dynamic (tunable) BioUp lighting. Static shows MDER values for 3500K and 4000K. Dynamic shows MDER values for Evening (0.43) and Daytime (0.98), with indications for dimming control and CCT control.
Static (non-tunable): Static BioUp is used when simple Melanopic Lighting is desired at all times.
Dynamic - (Tunable): Dynamic BioUp is used when Melanopic Lighting is desired to adjust during the day.