PowerWalker VI STL Series UPS User Manual

Overview

This manual provides instructions for the PowerWalker VI STL series of Uninterruptible Power Supplies (UPS), covering models 600, 800, 1000, 1200, 1500, and 2200.

The UPS offers automatic voltage regulation for unstable power grids and battery backup during power outages, ensuring stable power for your computer system.

Important Safety Instructions

SAVE THESE INSTRUCTIONS

This manual contains important safety instructions. Please read and follow all instructions carefully during installation and operation.

UPS System Installation

Unpacking

The box should contain the following:

Your new UPS can be used immediately upon receipt. However, to achieve maximum battery charge capacity, it is recommended to charge it for at least 8 hours. Charge loss may occur during transport and storage. To charge the battery, simply leave the unit plugged into an AC outlet. The unit will charge whether it is turned on or off.

Basic Operation

Front Panel

The front panel features:

LCD Brightness Setting: The auto-brightness function can be turned on/off by holding the button for 10 seconds. By default, the LCD auto-brightness function is off.

Back Panel

The back panel features:

Diagram Description (Front Panel): The front panel displays an LCD screen for status information, a power switch, and LED indicators.

Diagram Description (Back Panel): The back panel shows the input power cord, circuit breaker, USB communication port, RJ45/11 communication ports, and battery backup/surge protected outlets.

Technical Specifications

ModelVI 600 STLVI 800 STLVI 1000 STLVI 1200 STLVI 1500 STLVI 2200 STL
Capacity (VA/W)600/360800/4801000/6001200/7201500/9002200/1320
Input
Voltage Range162 ~ 290 VAC
Nominal Frequency50/60 Hz
Output
Output Voltage (Battery Mode)Simulated Sine Wave at 230 VAC +/-10%
Output Frequency (Battery Mode)50/60 Hz +/- 1%
Overload ProtectionCircuit breaker / Fuse
Dimensions (W x H x D) (mm)96 x 138 x 286148 x 178 x 298
BatterySealed maintenance-free lead-acid battery
Battery Type12V 7AH x112V 7.2AH x112V 9AH x112V 7AH x212V 7.2AH x212V 9AH x2
Typical Recharge Time8 hours
IndicatorsPower On, Low Battery, Overload, Fault
Audible AlarmsYes
Environment
Operating Temperature0°C to 40°C
Operating Relative Humidity0 to 90% (Non-condensing)
Management
Auto-chargingYes
Auto-restartYes
Communication PortsUSB COMM. Port (HID support), RJ45/11 Protection Ports

LED Indicator Definitions

The UPS uses various indicators to show its status:

Indicator States:

Troubleshooting

ProblemPossible CauseSolution
UPS does not provide expected runtimeBatteries are not fully charged.
Battery is slightly worn.
Charge the battery by leaving the UPS on.
Contact technical support.
UPS does not turn on.The ON/OFF switch is designed to prevent damage by quickly turning off and on.
The unit is not connected to an AC outlet.
Battery is discharged.
Turn off the UPS. Wait 10 seconds, then turn the UPS on.
The unit must be plugged into a 230V AC 50/60 Hz outlet.
Contact technical support.
Outlets do not provide power to equipmentMechanical problem.
Circuit breaker tripped due to overload.
Batteries are discharged.
Contact technical support.
Turn off the UPS and disconnect at least one unit of connected equipment. Disconnect the UPS power cord, then push the circuit breaker handle. Allow the unit to recharge for at least 4 hours.
Contact technical support.
Fault Code F09Batteries are discharged.Turn off the computer and charge the battery immediately.
Fault Code F12Unit is damaged by a voltage surge or overvoltage.Contact technical support.
Fault Code F13Output Short: Output circuit short-circuit.Turn off the UPS. There may be problems with the connected equipment, disconnect it and check again.
Fault Code F14Battery voltage is too low.
Battery is overcharged.
Contact technical support.
Overload Condition: Your equipment requires more power than the UPS can provide. It will shut down.Turn off secondary equipment. If this resolves the overload problem, the UPS will return to normal operation.

PowerMaster+ Management Software

The PowerMaster+ management software provides a user-friendly interface for managing your power systems. The graphical user interface is intuitive and displays essential power supply information at a glance.

Installation Procedure:

  1. Download PowerMaster+ from the website: http://powermaster.powerwalker.com/
  2. Double-click the file and follow the installation instructions.

After the computer restarts, the Power Master+ program will appear as a blue icon in the system tray.

Certifications and Compliance

The UPS complies with relevant safety and environmental standards. Look for symbols like:

PDF preview unavailable. Download the PDF instead.

PW STL Manual UA Aspose.Words for .NET 25.2.0

Related Documents

Preview PowerWalker Basic VI STL Series UPS User Manual
User manual for the PowerWalker Basic VI STL Series Uninterruptible Power Supply (UPS), covering safety instructions, installation, operation, technical specifications, and troubleshooting.
Preview PowerWalker Basic VI STL Series User Manual
User manual for the PowerWalker Basic VI STL Series UPS, covering safety instructions, installation, operation, technical specifications, and troubleshooting.
Preview Руководство пользователя PowerWalker VI серии STL: Безопасность, установка и эксплуатация
Полное руководство пользователя для источников бесперебойного питания PowerWalker VI серии STL (модели 600-2200 ВА). Содержит важные инструкции по безопасности, шаги установки, основные операции, технические характеристики и устранение неисправностей.
Preview PowerWalker Basic VI STL Series UPS User Manual and Specifications
Comprehensive user manual for the PowerWalker Basic VI STL Series UPS, covering installation, operation, troubleshooting, and technical specifications for models 600 to 2200.
Preview PowerWalker Basic VI Serie STL UPS User Manual
User manual for PowerWalker Basic VI Serie STL Uninterruptible Power Supply (UPS) models 600, 800, 1000, 1200, 1500, 2200. Covers safety instructions, installation, operation, technical specifications, troubleshooting, and software download.
Preview PowerWalker 1000VA/1500VA Line Interactive Sinewave UPS User Manual
This user manual provides detailed information on the PowerWalker 1000VA and 1500VA Line Interactive Sinewave UPS models, including safety instructions, installation, operation, battery replacement, troubleshooting, and technical specifications.
Preview PowerWalker VI 650-3000 LCD Quick Guide
This document provides a quick guide to the PowerWalker VI 650-3000 LCD series of Uninterruptible Power Supplies (UPS), detailing front and rear panel components, alarm functions, and technical specifications.
Preview Instrukcja Obsługi PowerWalker Basic VI STL UPS
Przewodnik użytkownika dla serii zasilaczy bezprzerwowego zasilania (UPS) PowerWalker Basic VI STL. Zawiera instrukcje bezpieczeństwa, instalacji, obsługi i rozwiązywania problemów dla modeli 600-2200VA.