Viessmann VITOCAL IND-C Cassette Ductless System
Technical Data Manual
Model Numbers and Pricing: See Price List
DLFSCAH, DLFSCBH, and DLFLCAH
Models 09XAK, 12XAK, 18XAK, 24XAK, 36XAK, and 48XAK
Cassette Ductless System
Key Features and Benefits
Low Sound Levels: Whisper quiet operation with no indoor compressors, minimizing noise disruption.
Secure Operation: Units are connected only by refrigerant piping and wiring, preventing intrusion through ductwork. Outdoor units can be placed close to exterior walls for protection.
Fast Installation: Simple to install with a mounting bracket for indoor units. Minimal disruption during installation.
Simple Servicing and Maintenance: Easy access to the control compartment and draw-thru outdoor section design for coil cleaning.
Built-in Reliability: Designed for years of trouble-free operation with protection against freeze-up and high evaporator temperatures.
Individual Room Comfort: Allows for individual room control, with an air sweep feature for optimal air mixing.
Economical Operation: Provides heating or cooling only where needed, reducing energy consumption.
Easy-to-Use Controls: Microprocessor-based controls with a user-friendly wireless remote control.
Factory Installed Condensate Lift Pump: Offers installation flexibility.
Agency Listings: AHRI and ETL certified.
Model Number Nomenclature
The model number indicates key features such as:
- DLF: Fan Coil Unit
- S & L: Model designation
- C: Indoor Fan Coil Type (Cassette)
- H: Indoor Fan Coil Type (Heat Pump)
- Capacity: Indicated by numbers (e.g., 09 for 3/4 Ton, 48 for 4 Ton)
- X: Not Used
- A: Variation
- K: Voltage (208/230-1-60)
Standard Features and Accessories
Indoor Unit Accessories
- Grille (Required for installation)
- Mounting Brackets
- Low Voltage Controls
Comfort Features
- Microprocessor Controls
- Wired Remote Control
- Wireless Remote Control
- Wi-Fi Remote Control
- Automatic Horizontal Air Sweep
- Air Direction Control
- Auto Restart Function
- Cold Blow Protection On Heat Pumps
- Freeze Protection Mode On Heat Pumps
- Turbo Mode
- Silence Mode
- Auto Changeover On Heat Pumps
- Follow Me
Energy Saving Features
- Sleep Mode
- Stop/Start Timer
- 46°F Heating Mode (Heating Setback)
Safety and Reliability
- Indoor Coil Freeze Protection
- Indoor Coil High Temp Protection in Heating Mode
- Aluminum Golden Hydrophilic pre-coated fins
Ease Of Service And Maintenance
- Cleanable Filters
- Diagnostics
- Liquid Line Pressure Taps
- Condensate Drain Adaptor
Application Flexibility
- Condensate Lift Pump
Accessories
ORDERING NO. | DESCRIPTION | FOR MODELS |
---|---|---|
KSACN0101AAA | Wired Remote Control with Timer Function | Sizes 09 - 18 |
KSACN0501AAA | Wired Remote Control 7 day Programmable | All sizes |
KSALG0202AAA | Grille/Ceiling Panel 3ft x 3 ft | Sizes 24-48 |
KSAIF0401AAA | Wi-Fi Kit | All sizes |
53DS-900---089 | Insulated 25' Line Set - 1/4" x 3/8" | Size 09 |
53DS-900---008 | Insulated 25' Line Set - 1/4"x1/2" | Sizes 12, 18 |
Dimensions
Detailed dimensions for indoor units are provided in tables and diagrams for various sizes (9K through 48K).
Figure 4: Indoor Unit (Sizes 9-18) illustrates the unit dimensions and packaging details.
Figure 5: Indoor Unit (Sizes 24-48) provides detailed dimensions for larger units.
A table lists the dimensions (A, B, C, D) for capacities 24K, 36K, and 48K.
Clearances
Figure 6: Clearances shows the recommended installation clearances for the indoor unit, including supply and return air paths, and overhead clearance.
- Minimum 39.4 inches (1000mm) clearance around the unit.
- Minimum 3 feet (1 meter) for supply air.
- Maximum 16 feet (5 meters) for supply air.
- Minimum 10.2 inches (260mm) overhead clearance.
- Minimum 11.4 inches (290mm) overhead clearance.
Specifications
A comprehensive table details system specifications for both Cooling and Heat Pump modes across various sizes (9K to 48K).
Key specifications include:
- Electrical: Voltage, Phase, Cycle, MCA, Power Supply.
- Controls: Wireless and Wired Remote Controller availability.
- Operating Range: Cooling and Heating Indoor Dry Bulb (DB) Min-Max and Wet Bulb (WB) Min-Max.
- Piping: Pipe Connection Sizes (Liquid and Suction).
- Indoor Coil: Face Area, No. Rows, Fins per inch, Circuits.
- Unit Dimensions: Body and Panel Width, Height, Depth, and Net Weight.
- Number of Fan Speeds: 3
- Airflow: CFM values for Low, Medium, and High fan speeds.
- Air Throw Data: Maximum approximate air throw in feet (meters).
- Sound Pressure: Cooling and Heating Operation Indoor Sound Pressure in dBa (L/M/H).
Figure 10: Sound Pressure Testing Method illustrates the testing setup.
Fan and Motor Specifications
Detailed specifications for the indoor fan motor are provided, including:
- Material, Type, Diameter, Height, Model, Voltage, Phase, FLA, Insulation Class, Safe Class, Input/Output Power, Range of Current, Rated Current, Capacitor, Rated HP, Speed (RPM), and Max Input.
Wiring Diagrams
Wiring diagrams are provided for different unit sizes:
- Figure 11: Wiring Diagram (Sizes 9K-24K)
- Figure 12: Wiring Diagram (Sizes 36K-48K)
A table lists the function of various codes (CN1, CN3, etc.) corresponding to connections on the mainboard.
Guide Specifications
Part 1 - GENERAL
- 1.01 System Description: Indoor, in-ceiling cassette, direct-expansion fan coils matched with heat pump outdoor units.
- 1.02 Agency Listings: Rated per AHRI Standards 210/240.
- 1.03 Delivery, Storage, And Handling: As per manufacturer recommendations.
- 1.04 Warranty: For inclusion by specifying engineer.
Part 2 - PRODUCTS
- 2.01 Equipment:
- General: Indoor, direct-expansion, ceiling-mounted fan coil with cooling/heating coil, fan, motor, piping, electrical controls, microprocessor control system, and integral temperature sensing.
- Unit Cabinet: Zinc-coated steel, fully insulated, with high-impact polystyrene grilles.
- Fans: Centrifugal direct-drive blower with automatic, motor-driven vertical air sweep and adjustable louvers (2, 3, or 4-way discharge).
- Coil: Copper tube with aluminum fins, mechanically expanded, and golden hydrophilic pre-coated. Includes a drip pan with a factory-installed condensate lift pump.
- Motors: Open drip-proof, permanently lubricated ball bearing with inherent overload protection, 7-speed fan motors.
- Controls: Microprocessor-based system for temperature control, fan speed, and self-diagnostics. Wireless remote controller can act as the temperature sensing location.
- Functions: Automatic restart, 24-hour timer, temperature sensing, indoor coil freeze protection, wireless infrared remote control, automatic air sweep, dehumidification mode, fan-only operation, diagnostics, user-selectable fan speed (high, medium, low, auto), automatic heating-to-cooling changeover, and indoor coil high temperature protection.
- Filters: Factory-supplied cleanable filters.
- Electrical Requirements: Indoor fan motor operates on 208-230V. Power supplied from outdoor unit.
- Operating Characteristics: Minimum SEER and HSPF as listed on specifications table.
- Refrigerant Lines: Lines can be oriented for left, right, or back connection and must be insulated.