Viessmann Vitocal 100-S

Ductless Single Zone Heat Pump Solution

AIR-TO-AIR HEAT PUMP SYSTEM

Innovative High-Performing HVAC Solutions for Single Zone Comfort

The Vitocal 100-S offers reliable comfort in extreme climates, featuring a powerful low ambient air-to-air heat pump system. It utilizes R454B refrigerant.

The system cuts energy costs up to 60% while providing dependable performance in temperatures ranging from -22°F to 122°F (-30°C to 50°C).

A temperature-sensing, wireless remote controller is included with most indoor units to help adjust and maintain ideal temperatures at the user's exact location within the room.

Ductless systems, often called "mini-splits," are increasingly popular for homes and businesses. They function similarly to traditional HVAC systems but without the need for ductwork. The system connects a single outdoor unit to one or more indoor units via flexible refrigerant tubing, simplifying installation. Because indoor units are placed directly in the room, they offer precise temperature control, enhanced energy efficiency, and cost-effective comfort year-round.

Versatile HVAC Systems For Endless Comfort Possibilities: Ductless systems generate climate-controlled air without traditional ductwork. Their compact and sleek design allows for use in single or multiple zones, creating personalized HVAC systems. Indoor units integrate neatly into spaces, installed unobtrusively yet effectively to direct airflow throughout the room. Indoor units connect to the outdoor unit via a hidden conduit.

Ductless Solutions Deliver On Benefits: Viessmann offers a family of flexible ductless solutions designed to meet various needs. These systems are extremely efficient and high-performing, addressing common heating and cooling challenges.

Inverter Technology That Adapts To Your Climate: Viessmann ductless systems employ inverter technology that continuously adjusts the compressor speed based on changing conditions, ensuring consistent comfort with lower energy usage. Enjoy year-round comfort with powerful low ambient heating and cooling down to -22°F (-30°C), maintaining 100% heating capacity at 5°F (-15°C).

Reasons to Love Ductless

Bring Comfort To Any Space In Any Condition

With extreme temperature performance, Viessmann ductless units provide reliable heating and cooling even in extreme weather, from -22°F to 122°F (-30°C to 50°C). With indoor unit choices for every space and style, you can easily deliver and maintain individualized comfort to a single room or an entire home. Single zone units allow the simple pairing of one indoor unit per outdoor unit.

Save On Energy And Operational Costs

Increase comfort with lower energy use. Our single zone ductless units deliver up to 27.5 SEER2 and 14.8 HSPF2 ratings. Reduce costs with ENERGY STAR® certified units.

Enjoy Ultimate System Flexibility and Ease of Use

Products feature an intelligent Eye Sensor. This unique occupancy sensor detects activity in a room and adjusts the angle of airflow for optimum comfort. Flexible modes allow for maximum comfort, such as Eco Mode for extra efficiency, or Turbo Mode to quickly cool or heat a space.

Sustainable Solution

High Efficiency R454B refrigerant achieves a 75% reduction in global warming potential and is non-ozone depleting for a lower climate impact.

Improve Air Quality

Breathe easier with enhanced indoor air quality. Our built-in reusable filters (available in all indoor units) effectively remove odors, allergens, and pollutants for cleaner, fresher air and lower maintenance costs. Simply pull them out, rinse them off, and re-install.

Rapid Cooling and Heating

After startup, the compressor quickly reaches maximum speed, cooling or heating the room in minutes.

Whisper Quiet Operation

Ultra-quiet operation reduces noise pollution both indoors and out, creating more peaceful, comfortable spaces.

Deliver Personalized Comfort to Any Room

The Vitocal 100-S system can be configured to deliver personalized comfort to any room in your home. The diagram illustrates how different areas within a house, such as attics, sunrooms, garages, basements, and rooms that are too hot or too cold, can be effectively managed with specific temperature settings (e.g., 76°F/24°C in sunrooms, 68°F/20°C in rooms that are too cold, 72°F/22°C in garages).

Options for Every Space & Style

Select the system that's right for you or find the perfect combination for whole-home comfort. Viessmann offers various indoor unit types:

  • HIGH WALL: Wall-mounted, Whisper-quiet, Eco mode.
  • FLOOR CONSOLE OR UNDER CEILING: Mounted near floor or under ceiling, Slim profile, Outside air intake to keep air fresh and clean.
  • DUCTED: Recessed into wall or ceiling, Maximum installation flexibility, Improved ventilation.
  • CEILING CASSETTE: Recessed into ceiling or under floor, Discrete or hidden installation, 360-degree airflow.
  • MULTI-POSITION AIR HANDLER: Connects to existing ductwork, Replaces existing furnace, Hidden from view.
  • ONE-WAY CASSETTE: Recessed into ceiling, Slim and compact, Follow Me temperature sensor.
  • OPTIONAL WIRED CONTROLLER: Wall-mounted, 7-day programmable, Customizable schedules.

Simple Installation and Maintenance

Flexible Application

Piping flexibility allows for a total piping length of up to 164 ft. (50 m.).

Minimal Installation

Installation is straightforward as there are no ducts, eliminating the need for tearing open walls, patching, or repainting.

Low Ambient Cooling Kit

A built-in Low Ambient Cooling Kit or specially designed PCB allows outdoor fan speeds to be changed automatically based on temperature, enabling cooling operation even in low ambient temperatures.

One-Person Installation & Cleaning

Easy-install mounting brackets firmly support the high wall unit, while tabs prop open the cover for hassle-free cleaning and filter changes.

Future Ready Refrigerant

The sustainable and highly efficient R454B refrigerant provides a 75% less Global Warming Potential (GWP) and Zero Ozone Depletion Potential (ODP), maintaining high performance even in harsh climates.

Third-Party Thermostat Compatibility

With the optional 24V interface kit, Viessmann ductless systems are compatible with any third-party or smart thermostat.

Factory Matched

Indoor units are engineered to match perfectly with Viessmann Vitocal 100-S outdoor units to deliver maximum performance and comfort.

Larger Capacity Options

The Viessmann single zone line of ductless heat pumps is offered in capacities suitable for light commercial applications, while still providing the quiet, optimized performance found in residential capacities.

Challenges Ductless Can Solve

  • Older buildings with baseboard heating or no ductwork
  • Rooms that are difficult to heat or cool
  • Attic or garage buildings
  • Tight quarters

Benefits at a Glance

  • Energy savings - Up to 27.5 SEER2 and 14.8 HSPF2.
  • Comfort in any climate - Operates in temperatures as low as -22°F (-30°C) and as high as 122°F (50°C). Can serve as the primary heat source, eliminating the need for a backup.
  • Environmentally Sustainable R454B Refrigerant.
  • Easy maintenance and Installation - Reusable filters enable higher efficiency and lower costs. No major renovations, patching, or painting required.
  • Personalized comfort matched indoor units for every space and style.
  • Flexible options - Compatible with third-party thermostats with built-in 24V interface kit.
  • ENERGY STAR certified models.

Performance Data

High Wall Indoor Unit (Vitocal IND-H / D5FSHAH Series)

Indoor model D5FSHAH06XAK D5FSHAH09XAK D5FSHAH12XAK D5FSHAH18XAK D5FSHAH24XAK D5FSHAH30XAK D5FSHAH33XAK
Power supply (V;Ph;Hz) 208/230V;1Ph;60HZ 208/230V;1Ph;60HZ 208/230V;1Ph;60HZ 208/230V;1Ph;60HZ 208/230V;1Ph;60HZ 208/230V;1Ph;60HZ 208/230V;1Ph;60HZ
Cooling Rated Capacity (DOE A2 - 95°F) (Btu/h) 6000 9000 12000 18000 24000 30000 33000
Cooling Capacity Range (Btu/h) 2300~12600 3800~13500 3800~14600 8800~19400 12600~27900 6500~32800 15000~37000
SEER2 (Btu/h.W) 25.7 27.5 25.5 21.5 21.2 20.5 19.6
EER2 (DOE A2 - 95°F) (Btu/h.W) 18 15.5 13.5 12.5 13 12 12
Heating Rated Capacity (DOE H12 - 47°F) (Btu/h) 7000 12000 12000 18000 29000 30000 36000
Heating Capacity Range (Btu/h) 3000~11000 3800~16000 3800~16000 11200~19500 11800~29700 12600~31400 19700~37800
COP (DOE H12 - 47°F) (W/W) 4.2 3.76 3.76 3.26 3.42 3.08 3.37
HSPF2 IV (Btu/h.W) 14.8 12.5 10.5 11 13.5 9.5 10.5
HSPF2 V (Btu/h.W) 11.5 9.5 8 8.5 9.8 7.2 8.6
Cooling Rated Capacity (DOE B2 - 82°F) (Btu/h) 6700 9500 12700 18500 26600 32600 37000
EER2 (DOE B2 - 82°F) (Btu/h.W) 23.8 20.5 16.5 15.5 16.3 14.9 15.4
Heating Rated Capacity (DOE H32 - 17°F) (Btu/h) 7900 9800 9800 15000 21000 20400 30000
COP (DOE H32 - 17°F) (W/W) 2.78 2.7 2.7 2.55 2.88 2.52 2.69
Heating Maximum Capacity (17°F) (Btu/h) 9200 12800 12800 19200 25000 21500 30200
Heating Rated Capacity (DOE H42 - 5°F) (Btu/h) 7700 11500 11500 18000 24200 20000 35000
COP (DOE H42 - 5°F) (W/W) 2.39 1.8 1.8 1.92 2.34 2.03 1.98
Heating Maximum Capacity (5°F) (Btu/h) 7700 11500 11500 18000 24200 20000 35000

Cassette Indoor Unit (Vitocal IND-C / D5FSCAH, D5FLCAH Series)

Indoor model D5FSCAH09XAK D5FSCAH12XAK D5FSCAH18XAK D5FSCAH24XAK D5FLCAH36XAK D5FLCAH48XAK
Power supply (V;Ph;Hz) 208/230V;1Ph;60HZ 208/230V;1Ph;60HZ 208/230V;1Ph;60HZ 208/230V;1Ph;60HZ 208/230V;1Ph;60HZ 208/230V;1Ph;60HZ
Cooling Rated Capacity (DOE A2 - 95°F) (Btu/h) 9000 12000 16000 23400 36600 48000
Cooling Capacity Range (Btu/h) 3700~13600 3800~15100 7000~18500 12800~26200 4900~38000 4900~52700
SEER2 (Btu/h.W) 22.7 22.3 20 20.8 21.3 18.2
EER2 (DOE A2 - 95°F) (Btu/h.W) 14 12.7 12.5 12 12 10
Heating Rated Capacity (DOE H12 - 47°F) (Btu/h) 10000 12000 19000 25000 37000 53000
Heating Capacity Range (Btu/h) 5100~15700 5300~16200 8700~20000 11500~30700 11400~44600 19000~57400
COP (DOE H12 - 47°F) (W/W) 4 3.7 3.18 3.54 3.43 3.09
HSPF2 IV (Btu/h.W) 12.2 11.6 12.4 11.6 10.6 11
HSPF2 V (Btu/h.W) 9.3 8.9 9.5 9.2 8.8 8.8
Cooling Rated Capacity (DOE B2 - 82°F) (Btu/h) 10600 14800 17500 24400 37800 51000
EER2 (DOE B2 - 82°F) (Btu/h.W) 18.0 17.0 16.0 14.7 14.4 12.2
Heating Rated Capacity (DOE H32 - 17°F) (Btu/h) 9700 10000 14900 20400 30600 44000
COP (DOE H32 - 17°F) (W/W) 2.63 2.74 2.7 2.78 2.56 2.44
Heating Maximum Capacity (17°F) (Btu/h) 12600 12900 18000 23900 46200 48000
Heating Rated Capacity (DOE H42 - 5°F) (Btu/h) 11000 11500 17000 23800 37000 47500
COP (DOE H42 - 5°F) (W/W) 1.84 2 1.9 2.23 1.95 1.96
Heating Maximum Capacity (5°F) (Btu/h) 11000 11500 17000 23800 37000 47500

Ducted Indoor Unit (Vitocal IND-D / D5FSDAH Series)

Indoor model D5FSDAH06XAK D5FSDAH09XAK D5FSDAH12XAK D5FSDAH18XAK
Power supply (V;Ph;Hz) 208/230V;1Ph;60HZ 208/230V;1Ph;60HZ 208/230V;1Ph;60HZ 208/230V;1Ph;60HZ
Cooling Rated Capacity (DOE A2 - 95°F) (Btu/h) 6500 9000 12000 17000
Cooling Capacity Range (Btu/h) 3300~11800 3400~13500 3400~13500 6500~18800
SEER2 (Btu/h.W) 21.5 21.5 20 18
EER2 (DOE A2 - 95°F) (Btu/h.W) 14.5 13.5 12 12
Heating Rated Capacity (DOE H12 - 47°F) (Btu/h) 8000 10000 12500 19000
Heating Capacity Range (Btu/h) 3700~13100 3800~16200 3800~16200 8900~22000
COP (DOE H12 - 47°F) (W/W) 4.01 3.53 3.39 3.37
HSPF2 IV (Btu/h.W) 13.8 12.5 10.2 10.8
HSPF2 V (Btu/h.W) 10.8 9.7 8.2 9
Cooling Rated Capacity (DOE B2 - 82°F) (Btu/h) 7500 10100 12700 18000
EER2 (DOE B2 - 82°F) (Btu/h.W) 20 18 14.5 15
Heating Rated Capacity (DOE H32 - 17°F) (Btu/h) 8000 9600 9600 15000
COP (DOE H32 - 17°F) (W/W) 2.7 2.5 2.5 2.7
Heating Maximum Capacity (17°F) (Btu/h) 9100 12600 13100 19000
Heating Rated Capacity (DOE H42 - 5°F) (Btu/h) 7800 11200 11800 18000
COP (DOE H42 - 5°F) (W/W) 2.4 1.89 1.9 2
Heating Maximum Capacity (5°F) (Btu/h) 7800 11200 11800 18000

Console Indoor Unit (Vitocal IND-F / D5FSFAH, D5FCFAH Series)

Indoor model D5FSFAH09XAK D5FSFAH12XAK D5FSFAH18XAK D5FCFAH18XAK D5FCFAH24XAK D5FSCAH36XAK D5FSCAH58XAK
Power supply (V;Ph;Hz) 208/230V;1Ph;60HZ 208/230V;1Ph;60HZ 208/230V;1Ph;60HZ 208/230V;1Ph;60HZ 208/230V;1Ph;60HZ 208/230V;1Ph;60HZ 208/230V;1Ph;60HZ
Cooling Rated Capacity (DOE A2 - 95°F) (Btu/h) 9000 12000 16000 17000 22000 36600 54000
Cooling Capacity Range (Btu/h) 3700~13700 3700~14000 6500~17200 7400~19200 12700~25600 4900~38000 20000~54500
SEER2 (Btu/h.W) 27.3 25 20.2 20.5 20.5 21.3 18.1
EER2 (DOE A2 - 95°F) (Btu/h.W) 15.2 12.7 12.5 12.6 12 12 9
Heating Rated Capacity (DOE H12 - 47°F) (Btu/h) 9000 12000 17000 19000 26000 37000 60000
Heating Capacity Range (Btu/h) 4400~16100 4400~16100 6500~20000 8300~20700 11300~29500 11400~44600 21700~65500
COP (DOE H12 - 47°F) (W/W) 4.43 3.88 2.85 3.07 3.34 3.43 3.02
HSPF2 IV (Btu/h.W) 10.9 10.6 10.3 10.3 12.1 10.6 10.7
HSPF2 V (Btu/h.W) 8.9 8.3 8.7 8.2 9.8 8.8 8.5
Cooling Rated Capacity (DOE B2 - 82°F) (Btu/h) 9600 12500 17000 18300 24600 37800 57500
EER2 (DOE B2 - 82°F) (Btu/h.W) 18.6 15.4 15 15.7 15.7 14.4 11.1
Heating Rated Capacity (DOE H32 - 17°F) (Btu/h) 9800 9800 14200 14400 20200 30600 41000
COP (DOE H32 - 17°F) (W/W) 2.71 2.71 2.6 2.54 2.74 2.56 2.33
Heating Maximum Capacity (17°F) (Btu/h) 12200 12300 18800 20200 23300 46200 58000
Heating Rated Capacity (DOE H42 - 5°F) (Btu/h) 11300 11300 17500 17000 24200 37000 54000
COP (DOE H42 - 5°F) (W/W) 1.84 1.88 1.95 1.86 2.16 1.95 1.91
Heating Maximum Capacity (5°F) (Btu/h) 11300 11300 17500 17000 24200 37000 54000

High Static Ducted Indoor Unit (Vitocal IND-D / D5FSDAH Series)

Indoor model D5FSDAH09XHK D5FSDAH12XHK D5FSDAH18XHK D5FSDAH24XHK
Power supply (V;Ph;Hz) 208/230V;1Ph;60HZ 208/230V;1Ph;60HZ 208/230V;1Ph;60HZ 208/230V;1Ph;60HZ
Cooling Rated Capacity (DOE A2 - 95°F) (Btu/h) 9000 12000 17500 24000
Cooling Capacity Range (Btu/h) 3000~13100 3000~13300 4000~20600 5000~28000
SEER2 (Btu/h.W) 20.6 20.2 18.5 19.2
EER2 (DOE A2 - 95°F) (Btu/h.W) 14 12 12.1 12
Heating Rated Capacity (DOE H12 - 47°F) (Btu/h) 9900 12000 19500 26000
Heating Capacity Range (Btu/h) 3900~16500 3900~16500 5400~23000 7300~31400
COP (DOE H12 - 47°F) (W/W) 3.88 3.63 3.6 3.81
HSPF2 IV (Btu/h.W) 13.8 10.6 11.1 11.7
HSPF2 V (Btu/h.W) 10.8 8.5 9 9.3
Cooling Rated Capacity (DOE B2 - 82°F) (Btu/h) 9800 13100 18700 25000
EER2 (DOE B2 - 82°F) (Btu/h.W) 17.9 15.6 16.2 14.7
Heating Rated Capacity (DOE H32 - 17°F) (Btu/h) 10200 10200 15000 21600
COP (DOE H32 - 17°F) (W/W) 2.45 2.59 2.89 2.7
Heating Maximum Capacity (17°F) (Btu/h) 12600 13900 20000 23500
Heating Rated Capacity (DOE H42 - 5°F) (Btu/h) 11900 12000 18000 24000
COP (DOE H42 - 5°F) (W/W) 1.85 1.95 2.1 2.18
Heating Maximum Capacity (5°F) (Btu/h) 11900 12000 18000 24000

One Way Cassette Indoor Unit (Vitocal IND-O / D5FSOAH Series)

Indoor model D5FSOAH06XAK D5FSOAH09XAK D5FSOAH12XAK D5FSOAH18XAK
Power supply (V;Ph;Hz) 208/230V;1Ph;60HZ 208/230V;1Ph;60HZ 208/230V;1Ph;60HZ 208/230V;1Ph;60HZ
Cooling Rated Capacity (DOE A2 - 95°F) (Btu/h) 6500 9000 12000 16700
Cooling Capacity Range (Btu/h) 3600~11200 4000~12900 4000~13900 5700~19000
SEER2 (Btu/h.W) 22 24 23 20.7
EER2 (DOE A2 - 95°F) (Btu/h.W) 15.2 14.7 13 12.5
Heating Rated Capacity (DOE H12 - 47°F) (Btu/h) 7400 10900 12500 20000
Heating Capacity Range (Btu/h) 3700~11500 3800~13900 4600~15200 8900~22000
COP (DOE H12 - 47°F) (W/W) 3.75 3.71 3.56 3.01
HSPF2 IV (Btu/h.W) 12 12.2 10.2 12.2
HSPF2 V (Btu/h.W) 10.3 9.5 8.2 9.2
Cooling Rated Capacity (DOE B2 - 82°F) (Btu/h) 6800 10000 13500 17500
EER2 (DOE B2 - 82°F) (Btu/h.W) 19.2 20 16.1 15
Heating Rated Capacity (DOE H32 - 17°F) (Btu/h) 7000 9000 9600 14500
COP (DOE H32 - 17°F) (W/W) 2.65 2.45 2.66 2.5
Heating Maximum Capacity (17°F) (Btu/h) 9500 11900 11900 18800
Heating Rated Capacity (DOE H42 - 5°F) (Btu/h) 8100 10600 11500 17500
COP (DOE H42 - 5°F) (W/W) 2.4 1.83 2 1.89
Heating Maximum Capacity (5°F) (Btu/h) 8100 10600 11500 17500

Air Handler Indoor Unit (Vitocal IND-A / D5FSAAH, D5FLAAH Series)

Indoor model D5FSAAH18XBK D5FSAAH24XBK D5FSAAH36XBK D5FLAAH36XAK D5FLAAH48XAK D5FLAAH60XAK
Power supply (V;Ph;Hz) 208/230V;1Ph;60HZ 208/230V;1Ph;60HZ 208/230V;1Ph;60HZ 208/230V;1Ph;60HZ 208/230V;1Ph;60HZ 208/230V;1Ph;60HZ
Cooling Rated Capacity (DOE A2 - 95°F) (Btu/h) 18000 23000 33000 36000 48000 54000
Cooling Capacity Range (Btu/h) 6000~20400 7500~27000 15000~39000 5700~36400 7300~55500 13700~58000
SEER2 (Btu/h.W) 18.2 18.8 16.7 17.3 17 15.4
EER2 (DOE A2 - 95°F) (Btu/h.W) 12 12 11.7 11.7 10.1 10
Heating Rated Capacity (DOE H12 - 47°F) (Btu/h) 19500 26000 35000 38000 50000 59000
Heating Capacity Range (Btu/h) 5000~21600 8800~29000 15000~41500 9500~44000 9500~65000 10000~66100
COP (DOE H12 - 47°F) (W/W) 3.64 3.5 3.66 3.39 3.5 3.36
HSPF2 IV (Btu/h.W) 10.1 10 10 9.5 10.2 9.2
HSPF2 V (Btu/h.W) 8.3 8 8.4 8 8.1 7.7
Cooling Rated Capacity (DOE B2 - 82°F) (Btu/h) 21000 25800 34200 36200 52000 56000
EER2 (DOE B2 - 82°F) (Btu/h.W) 15.4 15.6 14 13.5 12 11.5
Heating Rated Capacity (DOE H32 - 17°F) (Btu/h) 14000 16900 27400 28000 40000 41000
COP (DOE H32 - 17°F) (W/W) 2.6 2.4 2.58 2.2 2.5 2.6
Heating Maximum Capacity (17°F) (Btu/h) 19800 23800 33400 38000 42000 54000
Heating Rated Capacity (DOE H42 - 5°F) (Btu/h) 18000 23600 34000 38000 46000 53000
COP (DOE H42 - 5°F) (W/W) 2.2 2.1 2 2.06 2 2
Heating Maximum Capacity (5°F) (Btu/h) 18000 23600 34000 38000 46000 53000

Technical Data: Single Zone Outdoor Units (Vitocal 100-S / D5CSHAH, D5CSRAH and D5CLHAH Series)

06 09 12 18 24 30 33 36 48 58
ELECTRICAL
Voltage-Phase-Frequency (V/Ph/Hz) 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60
Max - Min Voltage Range 253-187 253-187 253-187 253-187 253-187 253-187 253-187 253-187 253-187 253-187
MCA (Minimum Circuit Ampacity) (A) 12 15 15 19 24.9 28 34 38 44 44
MOPA (Maximum Overcurrent Protection Ampacity) (A) 15 15 15 20 25 30 35 40 45 45
PIPING AND REFRIGERANT INFORMATION
Refrigerant Type R454B R454B R454B R454B R454B R454B R454B R454B R454B R454B
Charge Amount (lb. (kg)) 2.03(0.92) 2.2(1.00) 2.2(1.00) 3.46(1.57) 3.97(1.80) 5.29(2.4) 5.45(2.47) 7.94 (3.6) 7.94 (3.6) 9.48 (4.3)
Additional refrigerant charge (Oz/ft (g/m)) 0.16(15) 0.16(15) 0.16(15) 0.16(15) 0.32(30) 0.32(30) 0.32(30) 0.32 (30) 0.32 (30) 0.32 (30)
Liquid Pipe (size - connection type) (In (mm)) 1/4in (6.35mm) 1/4in (6.35mm) 1/4in (6.35mm) 1/4in (6.35mm) 3/8in (9.52mm) 3/8in (9.52mm) 3/8in (9.52mm) 3/8" (9.52) 3/8" (9.52) 3/8" (9.52)
Suction Pipe (size - connection type) (In (mm)) 3/8in (9.52mm) 3/8in (9.52mm) 3/8in (9.52mm) 1/2in (12.7mm) 5/8in (15.9mm) 5/8in (15.9mm) 3/4in (19mm) 3/4" (19) 3/4" (19) 3/4" (19)
AIRFLOW SPECIFICATIONS
Outdoor Air (CFM) 1235.29 1470.59 1470.59 1764.71 2235.29 2237.90 2235.29 3003.5 4240.3 4235.3
SOUND DATA
Outdoor Sound Pressure Level (dB(A)) 53 56 56 59 61.5 61 63 64.5 62.5 64.5
ENVIRONMENTAL SPECIFICATIONS
Indoor Cooling Min - Max DB (°F (°C)) 60~90 (16~32) 60~90 (16~32) 60~90 (16~32) 60~90 (16~32) 60~90 (16~32) 60~90 (16~32) 60~90 (16~32) 60~90 (16~32) 60~90 (16~32) 60~90 (16~32)
Cooling Operating Range Indoor Min - Max WB (°F (°C)) 59-84 (15-29) 59-84 (15-29) 59-84 (15-29) 59-84 (15-29) 59-84 (15-29) 59-84 (15-29) 59-84 (15-29) 59-84 (15-29) 59-84 (15-29) 59-84 (15-29)
Outdoor Cooling Min - Max DB (°F (°C)) -22~122 (-30~50) -22~122 (-30~50) -22~122 (-30~50) -22~122 (-30~50) -22~122 (-30~50) -13~122 (-25~50) -22~122 (-30~50) -22~122 (-30~50) -22~122 (-30~50) -22~122 (-30~50)
Indoor Heating Min - Max DB (°F (°C)) 32~86 (0~30) 32~86 (0~30) 32~86 (0~30) 32~86 (0~30) 32~86 (0~30) 32~86 (0~30) 32~86 (0~30) 32~86 (0~30) 32~86 (0~30) 32~86 (0~30)
Outdoor Heating Operating Range Min - Max DB (°F (°C)) -22~75 (-30~24) -22~75 (-30~24) -22~75 (-30~24) -22~75 (-30~24) -22~75 (-30~24) -13~75 (-25~24) -22~75 (-30~24) -22~75 (-30~24) -22~75 (-30~24) -22~75 (-30~24)
SYSTEM SIZE
System Size (208/230V) 6K 9K 12K 18K 24K 30K 33K 36K 48K 58K
Height (H) (in (mm)) 21.85 (555) 21.81 (554) 21.81 (554) 26.50 (673) 31.89 (810) 31.89(810) 31.89(810) 38.39 (975) 52.48 (1333) 52.48 (1333)
Width (W) (in (mm)) 30.12 (765) 31.69 (805) 31.69 (805) 35.04 (890) 37.24 (946) 37.24(946) 37.24(946) 38.58(980) 37.48 (952) 37.48 (952)
Depth (D) (in (mm)) 11.93 (303) 12.99 (330) 12.99 (330) 13.46 (342) 16.14 (410) 16.14(410) 16.14(410) 16.34 (415) 16.34 (415) 16.34 (415)
Weight - Net (lbs. (kg)) 62.17 (28.2) 72.75 (33.0) 72.75 (33.0) 99.87 (45.3) 130.29 (59.1) 142.86(64.8) 156.97 (712) 206.57 (93.7) 208.78 (94.7) 230.38 (104.5)

PDF preview unavailable. Download the PDF instead.

FLYER Vitocal 100-S US WEB Adobe PDF Library 17.0 Adobe InDesign 20.5 (Macintosh)

Related Documents

Preview Viessmann Vitocal 100-S: Ductless Single Zone Heat Pump Solution for Reliable Comfort
Discover the Viessmann Vitocal 100-S, a high-performance ductless single-zone heat pump system designed for reliable comfort in extreme climates. This solution offers energy efficiency, advanced features like an intelligent Eye Sensor, and flexible installation options for personalized climate control in any space. Learn about its sustainable R454B refrigerant, quiet operation, and comprehensive technical specifications.
Preview Viessmann Vitocal 100-S: Ducted Single Zone Heat Pump Solution
Discover the Viessmann Vitocal 100-S, a ducted single zone heat pump offering efficient, quiet, and versatile whole-home comfort. Learn about its advanced inverter technology, seamless integration, and performance across various climates, along with detailed technical specifications.
Preview Viessmann Vitocal 100-S: Ducted Single Zone Heat Pump System Overview
Explore the Viessmann Vitocal 100-S, a high-performance ducted single zone heat pump solution combining inverter technology with traditional HVAC. Learn about its energy efficiency, quiet operation, compact design, and versatile installation options for residential and light commercial applications, including detailed technical specifications.
Preview Viessmann Vitocal 100-WA Geothermal Heat Pump System: Efficient Comfort and Sustainability
Discover the Viessmann Vitocal 100-WA, an efficient geothermal heat pump system offering comfortable heating and cooling powered by the Earth's stable energy. Learn about its features, benefits, and technical specifications for residential and commercial applications.
Preview Viessmann Vitocal 100-WA: Efficient Geothermal Heat Pump System for Heating and Cooling
Discover the Viessmann Vitocal 100-WA, a high-performance, sustainable geothermal heat pump system offering efficient heating, cooling, and domestic hot water. Learn about its features, benefits, and technical specifications.
Preview Viessmann Vitocal 100-WA: Efficient Geothermal Heating and Cooling
Discover the Viessmann Vitocal 100-WA, a high-performance geothermal heat pump system offering efficient comfort for heating and cooling. Learn about its sustainable operation, advanced features, and benefits for residential and commercial applications.
Preview DLCURAH Series Technical Data Manual
Comprehensive technical data manual for the DLCURAH Series, covering specifications, dimensions, and performance data for single-zone outdoor ductless heat pump units.
Preview Viessmann VITOCAL IND-C Cassette Ductless System Technical Data Manual
Technical data manual for the Viessmann VITOCAL IND-C Cassette Ductless System, covering model numbers DLFSCAH, DLFSCBH, and DLFLCAH, with capacities ranging from 09XAK to 48XAK. Includes detailed specifications, dimensions, operating ranges, wiring diagrams, and features.