Viessmann Vitocal 100-S

Ducted Single Zone Heat Pump Solution

The best of two technologies in one whole-home system. High performing inverter heat pump technology with the familiarity of traditional ductwork.

Reasons to Love Viessmann Single Zone Ducted Heat Pump Solutions

The Best Of Two Technologies In One Whole-Home System

Viessmann single zone ducted heat pump solutions combine the best of inverter heat pumps and traditional HVAC. This provides quiet operation, a small footprint, and enhanced efficiency from inverter technology, alongside the high performance of traditional ducted units.

Performance in All Climates

With high performance in extreme temperatures, the Viessmann single zone ducted units offer reliable heating and cooling from -22°F to 130°F (-30°C to 55°C). They easily incorporate powerful and efficient comfort into new or existing ducted systems when paired with a traditional ducted air handler or cased evaporator coil.

Save On Energy And Operational Costs

Inverter technology ensures consistent temperature control and can reduce energy costs by up to 30%. Energy Star Certified units are available with ratings up to 18.0 SEER2 and 9.8 HSPF2.

Flexible Temperature Control

A built-in 24V interface allows easy connection with your preferred brand of thermostat, giving you full control over your system.

Hassle-Free Retrofitting

Easy integration with existing equipment and piping simplifies upgrading air systems. The Vitocal 100-S ducted single zone heat pump solution integrates seamlessly with existing systems and components.

Compact Design

The low-profile, unobtrusive outdoor unit delivers efficient comfort while occupying approximately a quarter of the space of a traditional top discharge outdoor unit, making it ideal for homes with limited outdoor space.

Whisper Quiet Operation

Ultra-quiet operation minimizes noise pollution both indoors and outdoors, creating more peaceful and comfortable living spaces.

The Vitocal 100-S Ducted Difference

Diagram Description: The system diagram illustrates the connection of the outdoor unit via an existing line set to an indoor unit. This indoor unit is then connected to existing ductwork. The system can be paired with a cased coil, gas furnace, or air handler, offering flexibility in system configuration.

Seamless Integration With Existing HVAC Systems

The Viessmann Vitocal 100-S ducted single zone heat pump is a unique solution that leverages space-saving inverter technology while allowing the reuse of existing HVAC line sets, ductwork, air handler, or furnaces. It is an ideal choice for upgrading current HVAC systems, constructing new homes, or adding to existing ones.

Spend Less On Variable Speed Features

Viessmann variable speed inverter technology provides high efficiency, whisper-quiet operation, and energy savings, all within a compact footprint, using only a quarter of the space of a traditional heat pump or air conditioner.

Save Time And Money With a Mess-Free Installation

The Vitocal 100-S ducted single zone heat pump solution simplifies pairing with existing setups, avoiding extensive wall modifications. The connection between outdoor and indoor units remains the same, allowing reuse of existing infrastructure for faster, cost-efficient installation.

Keep Your Furnace Or Go Electric

The Vitocal 100-S ducted single zone heat pump solution adapts to your comfort needs, whether you prefer a dual-fuel system with your existing furnace or a conversion to an all-electric heat pump system.

A Compact Outdoor Unit That Delivers Efficient Comfort in a Quarter of the Space

Diagram Description: A visual comparison shows a compact single zone ducted heat pump outdoor unit placed next to a traditional heat pump outdoor unit, emphasizing the significant space-saving advantage of the Vitocal 100-S.

It is well-known that inverter and traditional HVAC heat pump systems each offer distinct advantages. The Viessmann single zone ducted units allow you to benefit from both, combining the versatility and flexibility of traditional indoor HVAC equipment with advanced inverter heat pump technology.

Viessmann single zone ducted heat pump solutions maintain the characteristics of traditional ducted heating and cooling while utilizing inverter technology. These systems are compatible with residential fan coils and furnaces, ensuring seamless integration with your existing HVAC setup.

Versatile HVAC Systems For Endless Comfort Possibilities

Our single zone ducted heat pump solutions seamlessly blend inverter technology with traditional HVAC ducts, furnaces, and fan coils into a single system. This results in an exceptionally efficient, high-performance, and versatile solution suitable for residential and light commercial spaces.

Efficient Inverter Technology

Viessmann single zone ducted heat pump systems employ inverter technology that continuously adjusts compressor speed based on changing conditions, ensuring consistent comfort and lower energy usage. Enjoy year-round comfort with powerful low ambient heating and cooling capabilities, operating down to -22°F (-30°C).

Installation Flexibility & Benefits

Simple Retrofit Installation

Systems easily connect to existing line sets and ductwork, controlled via third-party thermostats without additional accessories or interfaces, ensuring a seamless, mess-free installation.

Low Ambient Cooling Kit

A built-in low ambient cooling kit or custom-designed PCB allows outdoor fan speeds to adjust automatically based on temperature, enabling cooling operation in low ambient conditions.

Easy Transport And Maneuverability

Units are lightweight enough to be carried by a single technician.

Multi-position Air Handler

Offers 4-way installation flexibility (Up flow, Down flow, Right, Left) with automatic airflow technology for static pressure up to 0.8 inWG.

Third-Party Thermostat Compatibility

Vitocal ducted heat pumps are designed to connect with your preferred brand of thermostat.

Minimal Footprint

The compact design facilitates easier installation, transport, and storage compared to traditional top discharge units.

Larger Capacity Options

The Viessmann Vitocal 100-S ducted single zone heat pumps are available in capacities sufficient for light commercial applications, delivering the same quiet, optimized performance as residential models.

Challenges Ducted Can Solve

Benefits at a Glance

Technical Data & Performance

Outdoor Unit (Standard Heat) Vitocal 100-S / DLCURAH Series

SYSTEM 1.5T 2T 2.5T 3T 4T 5T
Outdoor Model DLCURAH18AAK DLCURAH24AAK DLCURAH30AAK DLCURAH36AAK DLCURAH48AAK DLCURAH60AAK
ELECTRICAL
Voltage, Phase, Cycle 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60
MCA 16 A 19 A 20 A 24 A 34 A 34 A
Recommended Fuse Size 20 A 20 A 25 A 25 A 35 A 35 A
MOPA - Fuse Rating 20 A 30 A 35 A 40 A 50 A 60 A
Short Circuit Current Rating (SCCR) 2.4 kA 2.4 kA 2.4 kA 2.4 kA 2.4 kA 2.4 kA
OPERATING RANGE
Cooling Outdoor DB Min-Max 5~130°F (-15~55°C) 5~130°F (-15~55°C) 5~130°F (-15~55°C) 5~130°F (-15~55°C) 5~130°F (-15~55°C) 5~130°F (-15~55°C)
Heating Outdoor DB Min-Max -5~86°F (-15~30°C) -5~86°F (-15~30°C) -5~86°F (-15~30°C) -5~86°F (-15~30°C) -5~86°F (-15~30°C) -5~86°F (-15~30°C)
PIPING
Total Piping Length 98 ft (30 m) 164 ft (50 m) 164 ft (50 m) 213 ft (65 m) 213 ft (65 m) 213 ft (65 m)
Piping Lift* 65 ft (20 m) 82 ft (25 m) 82 ft (25 m) 98 ft (30 m) 98 ft (30 m) 98 ft (30 m)
Pipe Connection Size - Liquid 3/8 in (9.52 mm) 3/8 in (9.52 mm) 3/8 in (9.52 mm) 3/8 in (9.52 mm) 3/8 in (9.52 mm) 3/8 in (9.52 mm)
Pipe Connection Size - Suction 3/4 in (19 mm) 3/4 in (19 mm) 3/4 in (19 mm) 3/4 in (19 mm) 3/4 in (19 mm) 7/8 in (22 mm)
REFRIGERANT
Refrigerant Type R410A R410A R410A R410A R410A R410A
Charge 3.53 lbs (1.6 kg) 4.63 lbs (2.1 kg) 6.72 lbs (3.05 kg) 8.16 lbs (3.7 kg) 10.4 lbs (4.7 kg) 10.8 lbs (4.9 kg)
Add'l Refrigerant (between Std & Max Piping Lengths) 0.69 Oz/ft (65 g/m) 0.69 Oz/ft (65 g/m) 0.69 Oz/ft (65 g/m) 0.69 Oz/ft (65 g/m) 0.69 Oz/ft (65 g/m) 0.69 Oz/ft (65 g/m)
Metering Device EEV EEV EEV EEV EEV EEV
OUTDOOR COIL
Face Area 5 Sq. Ft. 5.9 Sq. Ft. 8.18 Sq. Ft. 8.14 Sq. Ft. 13.53 Sq. Ft. 13.36 Sq. Ft.
No. Rows 2 2 2.6 3 2 3
Fins per inch 20 20 18 18 18 18
Circuits 4 6 6 6 8 14
COMPRESSOR
Type Rotary Inverter Rotary Inverter Rotary Inverter Rotary Inverter Rotary Inverter Rotary Inverter
Model KSN140D21UFZ KTM240D57UMT KTF250D22UMT KTF250D22UMT KTQ420D1UMU KTQ420D1UMU
Oil Type VG74 VG74 VG74 VG74 VG74 VG74
Oil Charge 14.9 Fl. Oz. 22.7 Fl. Oz. 22.7 Fl. Oz. 22.7 Fl. Oz. 47.3 Fl. Oz. 47.3 Fl. Oz.
Rated Current 9 RLA 14 RLA 16 RLA 17.6 RLA 24 RLA 24.6 RLA
AIRFLOW & SOUND
Airflow 1,450 CFM 1,765 CFM 3,000 CFM 2,235 CFM 4,500 CFM 4,412 CFM
Sound Pressure 54 dB(A) 60 dB(A) 62 dB(A) 61 dB(A) 59 dB(A) 61 dB(A)

Outdoor Unit (Standard Heat) Vitocal 100-S / DLCURAH Series - Performance Ratings

1.5T (18K) 2T (24K) 2.5T (30K) 3T (36K) 4T (48K) 5T (60K)
M RATINGS
Cooling Rated Capacity 18,000 Btu/h 24,000 Btu/h 30,000 Btu/h 36,000 Btu/h 47,000 Btu/h 57,000 Btu/h
Cooling Cap. Range Min-Max 5400~18700 Btu/h 7500~26000 Btu/h 9500~33000 Btu/h 8900~38900 Btu/h 10500~48000 Btu/h 4400~60200 Btu/h
SEER 19.0 19.4 19.5 18.0 17.3 18.0
EER 11.1 11.3 10.9 10.4 9.3 10.3
Heating Rated Capacity (47°F) 18,000 Btu/h 26,000 Btu/h 31,000 Btu/h 36,000 Btu/h 55,000 Btu/h 60,000 Btu/h
Heating Rated Capacity (17°F) 11,500 Btu/h 17,000 Btu/h 19,000 Btu/h 21,000 Btu/h 33,000 Btu/h 33,800 Btu/h
Heating Rated Capacity (5°F) 9,500 Btu/h 17,000 Btu/h 20,000 Btu/h 21,000 Btu/h 27,000 Btu/h 29,000 Btu/h
Heating Cap. Range Min-Max 5600~18700 Btu/h 5600~30000 Btu/h 12200~32000 Btu/h 6000~36400 Btu/h 11700~57000 Btu/h 11400~63100 Btu/h
HSPF 10.8 11.3 10.3 9.1 10.0 9.2
COP (47°F) 3.49 W/W 3.54 W/W 3.19 W/W 3.02 W/W 3.00 W/W 3.55 W/W
COP (17°F) 2.70 W/W 2.75 W/W 2.30 W/W 2.25 W/W 2.00 W/W 2.45 W/W
COP (5°F) 1.85 W/W 1.75 W/W 1.95 W/W 1.80 W/W 1.72 W/W 1.80 W/W
M1 RATINGS
Cooling Rated Capacity 18,000 Btu/h 24,000 Btu/h 30,000 Btu/h 36,000 Btu/h 47,000 Btu/h 57,000 Btu/h
Cooling Cap. Range Min-Max 5400~18700 Btu/h 7500~26000 Btu/h 9500~33000 Btu/h 8900~38900 Btu/h 10500~48000 Btu/h 4400~60200 Btu/h
SEER2 16.0 17.0 17.3 16.9 15.8 14.7
EER2 10.9 10.5 10.6 10.1 8.8 8.8
Heating Rated Capacity (47°F) 18,000 Btu/h 26,000 Btu/h 31,000 Btu/h 36,000 Btu/h 55,000 Btu/h 60,000 Btu/h
Heating Rated Capacity (17°F) 11,500 Btu/h 20,700 Btu/h 20,000 Btu/h 20,500 Btu/h 36,500 Btu/h 36,000 Btu/h
Heating Rated Capacity (5°F) 10,000 Btu/h 17,000 Btu/h 17,800 Btu/h 21,000 Btu/h 36,500 Btu/h 34,800 Btu/h
Heating Cap. Range Min-Max 5600~18700 Btu/h 5600~30000 Btu/h 12200~32000 Btu/h 6000~36400 Btu/h 11700~57000 Btu/h 11400~63100 Btu/h
HSPF2 8.8 9.2 8.5 8.2 9.4 8.5
COP (47°F) 3.50 W/W 3.45 W/W 3.25 W/W 3.39 W/W 3.15 W/W 3.45 W/W
COP (17°F) 2.75 W/W 2.40 W/W 2.45 W/W 2.40 W/W 2.30 W/W 2.35 W/W
COP (5°F) 1.90 W/W 2.00 W/W 1.75 W/W 1.88 W/W 1.98 W/W 1.89 W/W

Outdoor Unit (High Heat) Vitocal 100-S / DLCURAH Series

SYSTEM 1.5T - HH 2T - HH 2.5T - HH 3T - HH 4T - HH 5T - HH
Outdoor Model DLCURAH18ABK DLCURAH24ABK DLCURAH30ABK DLCURAH36ABK DLCURAH48ABK DLCURAH60ABK
ELECTRICAL
Voltage, Phase, Cycle 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60
MCA 16 A 20.5 A 23 A 41 A 42 A 42 A
Recommended Fuse Size 20 A 25 A 25 A 45 A 45 A 45 A
MOCP - Fuse Rating 20 A 35 A 35 A 50 A 50 A 60 A
Short Circuit Current Rating (SCCR) 2.4 kA 2.4 kA 2.4 kA 2.4 kA 2.4 kA 2.4 kA
OPERATING RANGE
Cooling Outdoor DB Min-Max -22~130°F (-30~55°C) -22~130°F (-30~55°C) -22~130°F (-30~55°C) -22~130°F (-30~55°C) -22~130°F (-30~55°C) -22~130°F (-30~55°C)
Heating Outdoor DB Min-Max -22~86°F (-30~30°C) -22~86°F (-30~30°C) -22~86°F (-30~30°C) -22~86°F (-30~30°C) -22~86°F (-30~30°C) -22~86°F (-30~30°C)
PIPING
Total Piping Length 98 ft (30 m) 164 ft (50 m) 164 ft (50 m) 213 ft (65 m) 213 ft (65 m) 213 ft (65 m)
Piping Lift* 65 ft (20 m) 82 ft (25 m) 82 ft (25 m) 98 ft (30 m) 98 ft (30 m) 98 ft (30 m)
Pipe Connection Size - Liquid 3/8 in (9.52 mm) 3/8 in (9.52 mm) 3/8 in (9.52 mm) 3/8 in (9.52 mm) 3/8 in (9.52 mm) 3/8 in (9.52 mm)
Pipe Connection Size - Suction 3/4 in (19 mm) 3/4 in (19 mm) 3/4 in (19 mm) 3/4 in (19 mm) 3/4 in (19 mm) 7/8 in (22 mm)
REFRIGERANT
Refrigerant Type R410A R410A R410A R410A R410A R410A
Charge 5.07 lbs (2.3 kg) 6.39 lbs (2.9 kg) 8.38 lbs (3.8 kg) 10.36 lbs (4.7 kg) 10.58 lbs (4.8 kg) 10.58 lbs (4.8 kg)
Add'l Refrigerant (between Std & Max Piping Lengths) 0.69 Oz/ft (65 g/m) 0.69 Oz/ft (65 g/m) 0.69 Oz/ft (65 g/m) 0.69 Oz/ft (65 g/m) 0.69 Oz/ft (65 g/m) 0.69 Oz/ft (65 g/m)
Metering Device EEV EEV EEV EEV EEV EEV
OUTDOOR COIL
Face Area 5.9 Sq. Ft. 8.16 Sq. Ft. 8.16 Sq. Ft. 14.08 Sq. Ft. 13.53 Sq. Ft. 13.29 Sq. Ft.
No. Rows 2 2 3 1.6 2 2.6
Fins per inch 20 20 20 18 18 20
Circuits 6 4 4 8 8 10
COMPRESSOR
Type Rotary Inverter Rotary Inverter Rotary Inverter Rotary Inverter Rotary Inverter Rotary Inverter
Model KTM240D57UMT KTM240D57UMT KTF310D43UMT EAPQ420D1UMUA EAPQ420D1UMUA EAPQ440D1UMUA
Oil Type VG74 VG74 VG74 VG74 VG74 VG75
Oil Charge 22.7 Fl. Oz. 22.7 Fl. Oz. 33.8 Fl. Oz. 49.4 Fl. Oz. 49.4 Fl. Oz. 43.96 Fl. Oz.
Rated Current 10 RLA 15 RLA 16.5 RLA 32 RLA 33 RLA 28 RLA
AIRFLOW & SOUND
Airflow 1,279 CFM 3,000 CFM 3,000 CFM 4,500 CFM 4,412 CFM 4,500 CFM
Sound Pressure 58 dB(A) 64 dB(A) 62 dB(A) 64 dB(A) 64 dB(A) 64 dB(A)

Outdoor Unit (High Heat) Vitocal 100-S / DLCURAH Series - Performance Ratings

1.5T - HH (18K) 2T - HH (24K) 2.5T - HH (30K) 3T - HH (36K) 4T - HH (48K) 5T - HH (60K)
M RATINGS
EnergyStar YES YES NO NO NO NO
Cooling Rated Capacity 18,000 Btu/h 24,000 Btu/h 30,000 Btu/h 36,000 Btu/h 47,000 Btu/h 55,000 Btu/h
Cooling Cap. Range Min-Max 6900~21000 Btu/h 6400~27000 Btu/h 10400~33600 Btu/h 12000~47400 Btu/h 18000~48000 Btu/h 18000~56000 Btu/h
SEER 20.0 20.0 18.0 18.0 16.0 16.4
EER 12.5 12.5 11 10.5 8.5 9
Heating Rated Capacity (47°F) 19,000 Btu/h 24,000 Btu/h 33,000 Btu/h 41,500 Btu/h 50,000 Btu/h 59,000 Btu/h
Heating Rated Capacity (17°F) 13,000 Btu/h 18,700 Btu/h 19,400 Btu/h 24,000 Btu/h 33,000 Btu/h 33,800 Btu/h
Heating Rated Capacity (5°F) 19,000 Btu/h 24,000 Btu/h 28,500 Btu/h 34,500 Btu/h 32,000 Btu/h 42,000 Btu/h
Heating Cap. Range Min-Max 2800~21000 Btu/h 10100~31000 Btu/h 12000~37000 Btu/h 9000~57200 Btu/h 20000~55000 Btu/h 20000~68000 Btu/h
HSPF 11.0 12.0 10.5 10.5 10.0 10.5
COP (47°F) 3.59 W/W 3.45 W/W 3.48 W/W 3.45 W/W 3.00 W/W 3.50 W/W
COP (17°F) 2.75 W/W 2.70 W/W 2.60 W/W 2.65 W/W 2.30 W/W 2.60 W/W
COP (5°F) 1.90 W/W 1.80 W/W 1.95 W/W 1.80 W/W 1.88 W/W 1.96 W/W
M1 RATINGS
Cooling Rated Capacity 18,000 Btu/h 24,000 Btu/h 30,000 Btu/h 36,000 Btu/h 47,000 Btu/h 55,000 Btu/h
Cooling Cap. Range Min-Max 6900~21000 Btu/h 6400~27000 Btu/h 10400~33600 Btu/h 12000~47400 Btu/h 18000~48000 Btu/h 18000~56000 Btu/h
SEER2 18.0 17.4 16.2 15.8 15.6 15.0
EER2 12.4 11.7 9.8 9.8 8.2 8.5
Heating Rated Capacity (47°F) 19,000 Btu/h 24,000 Btu/h 33,000 Btu/h 40,000 Btu/h 50,000 Btu/h 59,000 Btu/h
Heating Rated Capacity (17°F) 13,000 Btu/h 18,600 Btu/h 20,400 Btu/h 29,500 Btu/h 35,000 Btu/h 42,000 Btu/h
Heating Rated Capacity (5°F) 16,500 Btu/h 22,700 Btu/h 24,100 Btu/h 34,500 Btu/h 46,000 Btu/h 50,000 Btu/h
Heating Cap. Range Min-Max 2800~21000 Btu/h 10100~31000 Btu/h 12000~37000 Btu/h 9000~57200 Btu/h 20000~55000 Btu/h 20000~68000 Btu/h
HSPF2 9.2 9.8 8.8 9.5 9.3 9.0
COP (47°F) 3.60 W/W 3.40 W/W 3.30 W/W 3.35 W/W 3.15 W/W 3.00 W/W
COP (17°F) 2.50 W/W 2.40 W/W 2.30 W/W 2.40 W/W 2.30 W/W 2.60 W/W
COP (5°F) 2.00 W/W 1.85 W/W 1.80 W/W 1.95 W/W 1.90 W/W 1.96 W/W

Air Handler Indoor Unit Vitocal IND-A / DLFUAA Series

SYSTEM 18K 24K 30K 36K 48K 60K
Indoor Model DLFUAAH18XAK DLFUAAH24XAK DLFUAAH30XAK DLFUAAH36XAK DLFUAAH48XAK DLFUAAH60XAK
ELECTRICAL
Voltage, Phase, Cycle 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60
MCA 2.5 A 4 A 4.5 A 5 A 7.5 A 9 A
Recommended Fuse Size 5 A 5 A 5 A 10 A 10 A 10 A
MOPA - Fuse Rating 15 A 15 A 15 A 15 A 15 A 15 A
OPERATING RANGE
Cooling Indoor DB Min-Max 60~90°F (16~32°C) 60~90°F (16~32°C) 60~90°F (16~32°C) 60~90°F (16~32°C) 60~90°F (16~32°C) 60~90°F (16~32°C)
Heating Indoor DB Min-Max 32~86°F (0~30°C) 32~86°F (0~30°C) 32~86°F (0~30°C) 32~86°F (0~30°C) 32~86°F (0~30°C) 32~86°F (0~30°C)
PIPING
Pipe Connection Size - Liquid 3/8 in (9.52 mm) 3/8 in (9.52 mm) 3/8 in (9.52 mm) 3/8 in (9.52 mm) 3/8 in (9.52 mm) 3/8 in (9.52 mm)
Pipe Connection Size - Suction 3/4 in (19 mm) 3/4 in (19 mm) 3/4 in (19 mm) 3/4 in (19 mm) 3/4 in (19 mm) 7/8 in (22 mm)
REFRIGERANT
Refrigerant Type R410A R410A R410A R410A R410A R410A
Metering Device EEV EEV EEV EEV EEV EEV
INDOOR COIL
Face Area 3 Sq. Ft. 3 Sq. Ft. 3.8 Sq. Ft. 3.8 Sq. Ft. 3.8 Sq. Ft. 4.88 Sq. Ft.
No. Rows 3 3 4 4 4 5
Fins Per Inch 20 20 20 20 20 20
Circuits 6 6 10 10 10 14
AIRFLOW & SOUND
Number of Fan Speeds (low/med/high/turbo) 4 4 4 4 4 4
Airflow (lowest to highest) 488/529/576/618 CFM 629/694/759/824 CFM 712/806/894/1088 CFM 865/971/1082/1188 CFM 906/1094/1282/1471 CFM 1135/1359/1582/1806 CFM
Cooling Sound Pressure (low to high) 30.5/31.4/33.4/35.2 dB(A) 33.6/36.6/38.7/40.4 dB(A) 37.7/41.3/43.0/45.6 dB(A) 40.2/43.2/45.7/48.0 dB(A) 42.5/47.1/50.3/54.0 dB(A) 45.0/49.1/52.1/55.3 dB(A)
Heating Sound Pressure (low to high) 29.8/30.7/34.0/35.3 dB(A) 32.4/36.9/39.6/40.6 dB(A) 29.5/36.9/43.0/43.2 dB(A) 35.6/40.7/46.8/46.7 dB(A) 43.7/46.8/50.2/52.7 dB(A) 43.4/48.0/53.0/60.5 dB(A)
Max Static Pressure 0.8 In. W.G. 0.8 In. W.G. 0.8 In. W.G. 0.8 In. W.G. 0.8 In. W.G. 0.8 In. W.G.
Field Drain Pipe Size O.D. 3/4 in (19.1 mm) 3/4 in (19.1 mm) 3/4 in (19.1 mm) 3/4 in (19.1 mm) 3/4 in (19.1 mm) 3/4 in (19.1 mm)

Contact Information

Viessmann Manufacturing Company ULC
Waterloo, ON Canada
Phone: (800) 387-7373

Viessmann Sales Office
Langley, BC Canada
Phone: (877) 853-3288

Website: viessmann.ca

A Carrier Company.

PDF preview unavailable. Download the PDF instead.

vitocal 100-s ducted flyer Adobe PDF Library 17.0 Adobe InDesign 20.0 (Macintosh)

Related Documents

Preview Viessmann Vitocal 100-S: Ducted Single Zone Heat Pump System Overview
Explore the Viessmann Vitocal 100-S, a high-performance ducted single zone heat pump solution combining inverter technology with traditional HVAC. Learn about its energy efficiency, quiet operation, compact design, and versatile installation options for residential and light commercial applications, including detailed technical specifications.
Preview Viessmann Vitocal 100-S: Ductless Single Zone Heat Pump System for Efficient Comfort
Discover the Viessmann Vitocal 100-S, a high-performance, ductless single-zone heat pump system designed for reliable comfort in extreme climates. This system offers significant energy savings, advanced features like an intelligent Eye Sensor, and flexible installation options for personalized HVAC solutions in homes and businesses.
Preview Viessmann Vitocal 100-WA Geothermal Heat Pump System: Efficient Comfort and Sustainability
Discover the Viessmann Vitocal 100-WA, an efficient geothermal heat pump system offering comfortable heating and cooling powered by the Earth's stable energy. Learn about its features, benefits, and technical specifications for residential and commercial applications.
Preview Viessmann Vitocal 100-WA: Efficient Geothermal Heat Pump System for Heating and Cooling
Discover the Viessmann Vitocal 100-WA, a high-performance, sustainable geothermal heat pump system offering efficient heating, cooling, and domestic hot water. Learn about its features, benefits, and technical specifications.
Preview Viessmann Vitocal 100-WA: Efficient Geothermal Heating and Cooling
Discover the Viessmann Vitocal 100-WA, a high-performance geothermal heat pump system offering efficient comfort for heating and cooling. Learn about its sustainable operation, advanced features, and benefits for residential and commercial applications.
Preview DLCURAH Series Technical Data Manual
Comprehensive technical data manual for the DLCURAH Series, covering specifications, dimensions, and performance data for single-zone outdoor ductless heat pump units.
Preview Viessmann Vitocal 100-S: Ductless Single Zone Heat Pump Solution for Reliable Comfort
Discover the Viessmann Vitocal 100-S, a high-performance ductless single-zone heat pump system designed for reliable comfort in extreme climates. This solution offers energy efficiency, advanced features like an intelligent Eye Sensor, and flexible installation options for personalized climate control in any space. Learn about its sustainable R454B refrigerant, quiet operation, and comprehensive technical specifications.
Preview Vitocal 100-AW AM2V Application Guide
This guide provides detailed information and application examples for the Viessmann Vitocal 100-AW AM2V air-to-water heat pump system, covering installation, technical specifications, and various operational configurations.