iDimension Plus Upgrade Kit Installation Instructions
Installation of the upgrade kit allows an iDimension Plus system to be updated to the latest version.
Manuals are available from Rice Lake Weighing Systems at www.ricelake.com/manuals.
Warranty information is available at www.ricelake.com/warranties.
Illustration 1. Parts of the iDimension Plus Upgrade Kit
The upgrade kit includes the following parts:
Part Number | Item Number | Description | Quantity |
---|---|---|---|
150660 | 1 | Assembly screw M4-0.7 x 20 | 3 |
223603 | 2 | iDimension Plus 2.0 Main Unit | 1 |
223778 | 3 | iDim 2.0 Black Rear Plate | 1 |
65680 | 4 | External screws KEPS 6-32 | 6 |
222730 | 5 | DC Power Adapter | 1 |
206585 | - | Calibration Object for iDim Plus 2.0 | 1 |
227300 | - | Hardware Kit for iDimension Plus 2.0 | 1 |
Table 1. List of parts for the iDimension Plus upgrade kit (ref. 228864).
NOTE: For more information on the assembly procedures of the iDimension Plus system, consult the iDimension Plus assembly instructions (ref. 197164).
1.0 Disassembly of the Existing Head
1. Remove the rear screws and rear plate from the old read head using a Phillips head screwdriver.
Illustration 2 & 3: Location of rear screws
2. Disconnect the connection cables and the power adapter.
Illustration 4: Disconnected connections
3. Locate the keyhole slots on the top of the iDimension system pole.
4. Loosen the mounting screws without removing them using a hex wrench provided in the hardware kit.
Illustration 5: Location of keyhole slots
5. Lift to remove the old read head from the pole assembly.
IMPORTANT: When removing the read head, carefully pass the cables through the provided slot to avoid damaging them.
6. Replace the screws and the rear plate of the read head.
7. Discard the read head.
2.0 Reassembly of the Unit
1. Screw the mounting screws into the new read head. Do not tighten.
Illustration 6: Threaded mounting screws
2. Remove the screws and rear plate from the read head.
Illustration 7: Location of new rear screws (circled)
3. Carefully pass the cables through the provided slot.
4. Align, insert, and lower the mounting screw heads into the pole's keyhole slots.
5. Tighten the mounting screws.
6. Place the adapter onto the power cable.
Illustration 8: Power cable with adapter
7. Connect the cable connections and the power adapter (see Illustration 9).
Illustration 9: Connected cable and power adapter
8. Replace the screws and the rear plate.