LED FLUSH MOUNT KIT USER MANUAL

12-24VDC

CONTENTS

WIRING & FUNCTIONS

To Chassis Ground: BLACK

To +VDC: RED (Fuse Rating 12V@3A / 24V@2A)

For Low Power Warning: WHITE (Apply +VDC to WHITE wire while RED wire is activated for Low Power Operation.)

For Synchronization and Flash Pattern: YELLOW (Connect YELLOW wires of all kits together for synchronization. All kits should be set to the same pattern) *Actual approval will be based on the model purchased.

The LED Controller connects to the 2nd Lighthead via the extension cable. Ensure all unused bare wires are covered.

OPERATION

For Simultaneous or Alternating Synchronization:

  1. Apply +VDC to RED and YELLOW wires simultaneously to enter Flash Mode Selection.
  2. Remove YELLOW wire from +VDC and momentarily apply to +VDC to change mode selection:
    • Mode 1 = Head 1 & 2 flash alternately
    • Mode 2 = Head 1 & 2 flash simultaneously
  3. Exit Flash Mode Selection by removing +VDC.

For Flash Pattern Selection:

Flash Patterns

FP# Flash Patterns
1Single [2Hz]
2Double [R65]*
3Triple [2Hz]
4Quad [2Hz]
5Random
6Single
7Double
8Quad
9Quint
10Mega
11Ultra
12Single-Quad
13Single H/L
14Steady or Steady Double**

* Actual approval will be based on the model purchased.

** In Mode 2, lightheads will both steady-burn; in Mode 1, one lighthead will steady burn while the other does double flash.

INSTALLATION - FLUSH MOUNT

  1. Select a mounting location and drill one 1" (25.4mm) cut-out. NOTE: Mounting surface thickness is approximately 0.8~2.0mm.
  2. From the front, install the MOUNTING GROMMET onto the cut-out, and then insert the LIGHTHEAD.
  3. Ensure that the triangle mark on the lens is aligned vertically. NOTE: Optical stripes must align vertically to meet approved regulation.
  4. Where necessary, apply silicone around the reverse side to prevent from rotating.

INSTALLATION - BRACKET MOUNT (sold-separately)

  1. From the front, install the MOUNTING GROMMET onto the BRACKET, and insert the LIGHTHEAD.
  2. Ensure that the triangle mark on the lens is aligned vertically. NOTE: Optical stripes must align vertically to meet approved regulation.
  3. Secure the LIGHTHEAD onto the BRACKET with a screw (M3 x 8mm).
  4. Secure the BRACKET onto the desired mounting surface with screws (#6 x 18mm).

WIRING 2 KITS TOGETHER

The following schematic diagram illustrates wiring two kits together. The YELLOW wires from both controllers must be connected together for synchronization.

* Refer to Flash Pattern Chart on the opposite page.

NOTE: To achieve alternating patterns between Head 1A & 2B with 1B & 2A, simply reverse the lighthead outlets on one of the Controllers (both kits must be in Mode 1).

The diagram shows connections for two units. Each unit controller has connections for BLACK (to GND), RED (to +VDC, with a 12V@3A / 24V@2A fuse recommended, user-supplied), WHITE (for ON/OFF control), and YELLOW (for synchronization). Extension cables are used to connect to the lightheads.

NOTE: The mounting area varies from vehicle to vehicle. The diagram is not drawn to scale.

Models: UR04 Led Flush Mount Kit, UR04, Led Flush Mount Kit, Flush Mount Kit, Mount Kit

PDF preview unavailable. Download the PDF instead.

Cell2 UR04 UserManual Adobe PDF library 16.04 Adobe Illustrator 26.2 (Windows)

Related Documents

Preview Cell2 LED Flush Mount Kit User Manual - Wiring and Installation Guide
Comprehensive user manual for the Cell2 LED Flush Mount Kit (CR06). Provides detailed instructions on wiring for warning, low power, and cruise modes, operation for flash patterns and grouping, and installation methods including Pop-n-Lock and Bracket Mount systems. Covers 12-24VDC operation and regulatory alignment.
Preview Cell2 MICRO-BAR-EX LED Lightbar: Installation and Operation Guide
Comprehensive guide for the Cell2 MICRO-BAR-EX LED lightbar, covering permanent and magnetic mounting, wiring, flash pattern selection, and safety precautions. Includes detailed descriptions of all flash patterns.
Preview Cell2 LP22 4LED Square Warning Lighthead: Installation and Operation Guide
This guide details the installation, wiring, and operation of the Cell2 LP22 4LED Square Warning Lighthead. It covers connection diagrams, setting modes for simultaneous or alternating flash, selecting various flash patterns, resetting to factory defaults, and mounting procedures for both screw and quick mount options. Includes important safety cautions and torque specifications for optimal performance and longevity.
Preview Cell2 Legion FIT Operation Manual: Wiring and Functions
Comprehensive operation manual for the Cell2 Legion FIT lightbar, detailing wiring, power, and control functions including Warning, Dim, and Cruise modes with flash pattern selection.
Preview Warning Lighthead Installation and Wiring Guide - 86-M08210-0001.0
Detailed instructions for wiring, synchronization, and installation of the Cell2 Warning Lighthead (Model 86-M08210-0001.0). Includes flash pattern options and reset procedures.
Preview 9 LED Corner Warning Lighthead Manual - Installation and Operation Guide
Comprehensive manual for the Cell2 9 LED Corner Warning Lighthead (Model 86-M07510-0001.1), covering wiring, operation modes, synchronization, installation, and mounting positions for ECE R65 compliance.
Preview Cell2 Micro-BAR-EX LED Warning Light Bar - Permanent & Magnetic Mount Guide
Detailed information on the Cell2 Micro-BAR-EX LED warning light bar, including wiring, flash patterns, and instructions for permanent and magnetic mounting. Features product specifications and safety warnings.
Preview MINI LIGHTHEAD Manual - Wiring and Configuration Guide
This manual provides detailed instructions for wiring, configuring, and operating the MINI LIGHTHEAD (ID6) automotive warning light. It covers flash patterns, mode selection, synchronization, and example configurations for optimal vehicle safety lighting.