The R. STAHL 9276/10-21-40-00s is a loop-powered binary output device designed for intrinsically safe (Ex i) field circuits. It provides signals for Ex i solenoid valves, signal lamps, or horns. A key feature is its ability to operate without separate auxiliary power, drawing energy from the control current. The device offers galvanic isolation between the intrinsically safe outputs and the inputs.
Key advantages include:
- Extensive portfolio for a wide range of solenoid valves.
- Space-saving design with a narrow profile of 12.5 mm.
- Suitable for use up to SIL 3 (IEC/EN 61508).
Technical Data
Explosion Protection
Parameter | Value |
---|---|
Explosion Protection Zone | 2 |
Ex Interface Zone | 0, 1, 2, 20, 21, 22 |
IECEx Certificate Gas | IECEx IBE 17.0045X |
IECEx Gas Explosion Protection | Ex ec [ia Ga] IIC T4 Gc |
IECEx Certificate Dust | IECEx IBE 17.0045X |
IECEx Dust Explosion Protection | [Ex ia Da] IIIC |
IECEx Certificate Safety Shroud | IECEx IBE 17.0045X |
IECEx Safety Shroud Protection | [Ex ia Ma] I |
ATEX Certificate Gas | IBEXU 17 ATEX 1153 X |
ATEX Gas Explosion Protection | II 3 (1) G Ex ec [ia Ga] IIC T4 Gc |
ATEX Certificate Dust | IBEXU 17 ATEX 1153 X |
ATEX Dust Explosion Protection | II (1) D [Ex ia Da] IIIC |
ATEX Certificate Safety Shroud | IBEXU 17 ATEX 1153 X |
ATEX Safety Shroud Protection | I (M1) [Ex ia Ma] I |
cULus Certification | E81680 |
cULus Marking | Class I, Div. 2, Groups A,B,C,D; Class I, Zone 2, AEx/Ex nA Group IIC; AIS Class I,II,III, Div. 1, Groups A,B,C,D,E,F,G; Class I, Zone 0, [AEx ia]/[Ex ia] IIC T4; any mounting pos. Ta = 60°C (See Doc. 9276 6 031 001 3) |
Certifications | ATEX (IBE), IECEx (IBE), Canada (UL), Korea (KTL), SIL (exida), USA (UL), People's Republic of China (CQM); DNV |
Marine Approval | ATEX (EUK), People's Republic of China (CCC) |
Conformity Declarations |
Safety Data
Parameter | Value |
---|---|
Max. Current I. (Ex ia) | 87 mA |
Max. Power P. | 550 mW |
Max. permissible external capacitance C. for IIC | 0.108 μF |
Max. permissible external inductance L. for IIC | 5 mH |
Max. permissible external capacitance C. for IIB | 0.83 μF |
Max. permissible external inductance L. for IIB | 20 mH |
Max. permissible external capacitance C. for IIA | 2.93 μF |
Max. permissible external inductance L. for IIA | 45 mH |
Max. permissible external capacitance C. for IIIC | 0.83 μF |
Max. permissible external inductance L. for IIIC | 20 mH |
Max. permissible external capacitance C. for I | 2.93 μF |
Max. permissible external inductance L. for I | 45 mH |
Internal Capacitance C | Negligible |
Internal Inductance L | Negligible |
Max. Safety Voltage U | 253 V AC |
Intrinsically Safe Limits (External Inductance L / Capacitance C)
Group | L. [mH] | C. [µF] | ||
---|---|---|---|---|
1 mH | 2 mH | 0.052 µF | 0.065 µF | |
IIC | 1 mH | 2 mH | 0.052 µF | 0.065 µF |
IIB | 5 mH | 10 mH | 0.380 µF | 0.380 µF |
IIA | 5 mH | 20 mH | 0.600 µF | 0.610 µF |
IIIC | 5 mH | 10 mH | 0.380 µF | 0.380 µF |
I | 5 mH | 20 mH | 0.600 µF | 0.610 µF |
Functional Safety
Parameter | Value |
---|---|
SIL | 3 |
HFT | 0 |
SFF | 100% |
Lambda SD | 0 FIT |
Lambda SU | 50 FIT |
Lambda DD | 0 FIT |
Lambda DU | 0 FIT |
Electrical Data
Parameter | Value |
---|---|
Number of Channels | 1 |
Electrical Specifications
Parameter | Value |
---|---|
Auxiliary Power | None |
Max. Power Dissipation | 1.06 W |
Reverse Polarity Protection | Yes |
Galvanic Isolation | Yes |
Test Voltage per Standard | EN IEC 60079-11 |
Ex i Output to Input | 375 V AC Peak |
Input
Parameter | Value |
---|---|
Input Voltage for ON | 15 - 30 V |
Input Voltage for OFF | 0 - 5 V |
Output
Parameter | Value |
---|---|
Output Open Circuit Voltage U₂ | 21.9 V |
Max. Output Current Iₐ max | 40 mA |
Output Internal Resistance R | 287 Ω |
Switching Delay ON/OFF | ≤ 20 ms |
Switching Delay OFF/ON | ≤ 20 ms |
Output Settling Time | 20 ms |
Output State Indicator | LED yellow "STAT" |
Environmental Conditions
Parameter | Value |
---|---|
Ambient Temperature | -40 °C ... 60 °C (-40 °F ... +140 °F) |
Storage Temperature | -40 °C ... 80 °C (-40 °F ... +176 °F) |
Max. Relative Humidity | 10 ... 95% |
Usage at Altitude | < 2000 m |
Electromagnetic Compatibility | EN 61326-1 Industrial Environment; Immunity according to EN 61000-6-2; Radiated emissions according to EN 61000-6-4 |
Mechanical Data
Parameter | Value |
---|---|
Protection Rating (IP) | IP30 |
Protection Rating (IP) Terminals | IP20 |
Flame Retardancy (UL 94) | VO |
Housing Material | Polyamide |
Grid Dimension | 12.5 mm |
Width | 12.5 mm (0.49 in) |
Height | 114.5 mm (4.51 in) |
Length | 112.5 mm (4.43 in) |
Weight | 165 g (0.36 lb) |
Mounting / Installation
Mounting Type: DIN rail NS35/15, NS35/7.5
Installation Position: Vertical, Horizontal
Connection Type
Screw terminal
Conductor Cross-Section
Parameter | Value |
---|---|
Solid conductor min. | 0.2 mm² |
Solid conductor max. | 2.5 mm² |
Flexible conductor min. | 0.2 mm² |
Flexible conductor max. | 2.5 mm² |
Conductor Cross-Section AWG | 24 ... 14 |
Technical Drawings
Ex Area vs. Safe Area Diagram
A diagram illustrates the separation between the Ex area and the safe area, showing the intrinsically safe circuit (1) connected to the output and the input (2) receiving the control signal. The diagram indicates voltage and current relationships.
Dimensional Drawing
A dimensional drawing provides the overall dimensions of the unit in millimeters and inches, including width, height, and length. It also references compatible R. STAHL ISpac series modules.
Output Characteristic Curve
A graph shows the output characteristic curve for the 9276/10-21-40, plotting output current (Iₐ [mA]) against output voltage (Uₐ [V]). It indicates the open-circuit voltage of 21.9 V and a maximum output current of 40 mA.
Company Information
R. STAHL Schaltgeräte GmbH
Am Bahnhof 30
74638 WALDENBURG
Germany
Tel: +49 7942 943 1700
Fax: +49 7942 943 1777
Email: sales.de@r-stahl.com
Website: r-stahl.com