EK-Quantum Surface Radiator Setup Configurations
RADIATOR
EK-Quantum Surface Radiators
EK-Quantum Surface Radiators feature a classical U-shape coolant flow, with inlet and outlet ports located on the same side of the radiator. Users can select which port functions as the inlet and which as the outlet within their custom cooling loop.
SETUP 1
Illustrates the first flow direction setup for the EK-Quantum Surface P360M Radiator, a Multiport radiator. For non-multiport radiators, only one inlet and one outlet port can be utilized.
[Diagram showing inlet and outlet options on a radiator]
EK-Quantum Surface P360M
SETUP 2
Illustrates the second flow direction setup for the EK-Quantum Surface P360M Radiator, a Multiport Radiator. Similar to Setup 1, non-multiport radiators allow for a single inlet and outlet port.
[Diagram showing inlet and outlet options on a radiator]
EK-Quantum Surface P360M
Installation Guidelines
Important Note: Installation of this product should be performed by trained and experienced individuals. Installation is at the user's own risk. If you lack the necessary training or experience, please seek professional assistance. EKWB disclaims liability for any damages resulting from improper installation.
Before starting: Please adhere to these basic guidelines.
1. Manual Review: Carefully read the manual before commencing the installation process.
2. Fitting Installation: EK Fittings require minimal force to screw in securely, as the liquid seal is achieved through the rubber O-ring gaskets.
3. Coolant Recommendation: The use of high-quality, market-proven corrosion-inhibiting coolants is strongly recommended for all liquid cooling systems. Pure distilled water is not advised. For optimal results, EK recommends EK-CryoFuel Coolants.
Performance Tip: EK recommends using an equal number of inlets and outlets for optimal performance.
Mandatory Extenders: Extenders must be used on all inlet and outlet positions.
Extender Check: If extenders are moved from their original position, ensure they are tightened properly to prevent leaks.
Universal Setup: The port setup described applies to all EK-Quantum Surface radiator variants.
Multiport Radiator Feature: On Multiport Radiators, an additional port is located opposite the inlet/outlet side, intended for filling or draining the loop.
Important: This additional port should not be used as an inlet or outlet.
Exploded View of Removable Components
EK-QUANTUM SURFACE S SERIES
[Exploded view diagram of EK-Quantum Surface S Series radiator components]
- 2x QUANTUM SURFACE END TANK SHROUD (ALUMINIUM)
- 2x QUANTUM SURFACE EXTENDER
- 2x QUANTUM SURFACE SIDE PLATE (STAINLESS STEEL)
- 8x TORX SCREW M3 x 6 mm
- QUANTUM SURFACE TANK
For reference on picture above: EK-Quantum Surface S240
EK-QUANTUM SURFACE P SERIES
[Exploded view diagram of EK-Quantum Surface P Series radiator components]
- 2x QUANTUM SURFACE END TANK SHROUD (ALUMINIUM)
- 2x QUANTUM SURFACE EXTENDER
- 2x QUANTUM SURFACE SIDE PLATE (STAINLESS STEEL)
- 8x TORX SCREW M3 x 6 mm
- 3x QUANTUM SURFACE PLUG (MULTIPORT VERSION)
- QUANTUM SURFACE TANK
For reference on picture above: EK-Quantum Surface P360M
EK-QUANTUM SURFACE X SERIES
[Exploded view diagram of EK-Quantum Surface X Series radiator components]
- 2x QUANTUM SURFACE END TANK SHROUD (ALUMINIUM)
- 2x QUANTUM SURFACE EXTENDER
- 2x QUANTUM SURFACE SIDE PLATE (STAINLESS STEEL)
- 8x TORX SCREW M3 x 6 mm
- 3x QUANTUM SURFACE PLUG (MULTIPORT VERSION)
- QUANTUM SURFACE TANK
For reference on picture above: EK-Quantum Surface X420M