Important Safety Information and Guidelines
Please note the installation of the product is intended to be undertaken by an adequately trained and experienced person. You are installing the product at your own risk. If you are not properly trained or experienced or feel unsure about the installation procedure, please refrain from installing the product yourself and contact EKWB tech support for assistance. EKWB disclaims liability for any damages to the product as well as incidental, consequential, or indirect damages incurred due to improper or inappropriate installation.
Before you start using this product, please follow these basic guidelines:
- Carefully read the manual before beginning with the installation process.
- EK Fittings require only a small amount of force to screw them firmly in place since the liquid seal is ensured with the rubber O-ring gaskets.
- The use of quality market-proven corrosion-inhibiting coolants is always strongly recommended for any liquid cooling system.
- Do not use pure distilled water as a cooling liquid! For best results, EK recommends the use of EK-CryoFuel Coolants.
EK-Quantum Surface Radiators
EK-Quantum Surface Radiators have a classical U-shape coolant flow, with inlet and outlet both on one side of the radiator. However, you can still choose which port of the radiator will serve as an inlet, and which for the outlet in your custom loop.
Setup 1: First Flow Direction
The diagram illustrates the EK-Quantum Surface P360M radiator configured for the first flow direction. It shows inlet and outlet ports on one side, with labels indicating 'INLET OPTIONS' and 'OUTLET OPTIONS'. This setup is for multiport radiators; non-multiport radiators utilize a single inlet and single outlet port.
Setup 2: Second Flow Direction
The diagram illustrates the EK-Quantum Surface P360M radiator configured for the second flow direction. It shows inlet and outlet ports on one side, with labels indicating 'INLET OPTIONS' and 'OUTLET OPTIONS'. This setup is for multiport radiators; non-multiport radiators utilize a single inlet and single outlet port.
Recommendations and Notes:
- ⚠️ EK recommends using the same number of inlets and outlets for the most optimal performance!
- ⚠️ It is mandatory to use the extenders on any inlet and outlet position!
- ⚠️ If transferred from the stock position of the radiator to another, check if the extenders are tightened to avoid leakage!
- ℹ️ The same port setup applies for all EK-Quantum Surface radiator variants!
Multiport Radiator Fill/Drain Port
The diagram shows a multiport radiator with an additional port located on the side opposite the main inlet/outlet ports. This port is labeled 'FILL/DRAIN PORT' and is intended for filling or draining the cooling loop.
⚠️ It should not be used as an inlet or an outlet port!
Exploded View of Removable Components
EK-Quantum Surface S Series
For reference on picture above: EK-Quantum Surface S240
Components:
- 2x QUANTUM SURFACE END TANK SHROUD (ALUMINIUM)
- 2x QUANTUM SURFACE SIDE PLATE (STAINLESS STEEL)
- 2x QUANTUM SURFACE EXTENDER
- 8x TORX SCREW M3 x 6 mm
- QUANTUM SURFACE TANK
EK-Quantum Surface P Series
For reference on picture above: EK-Quantum Surface P360M
Components:
- 2x QUANTUM SURFACE END TANK SHROUD (ALUMINIUM)
- 2x QUANTUM SURFACE SIDE PLATE (STAINLESS STEEL)
- 2x QUANTUM SURFACE EXTENDER
- 8x TORX SCREW M3 x 6 mm
- 3x QUANTUM SURFACE PLUG (MULTIPORT VERSION)
- QUANTUM SURFACE TANK
EK-Quantum Surface X Series
For reference on picture above: EK-Quantum Surface X420M
Components:
- 2x QUANTUM SURFACE END TANK SHROUD (ALUMINIUM)
- 2x QUANTUM SURFACE SIDE PLATE (STAINLESS STEEL)
- 2x QUANTUM SURFACE EXTENDER
- 8x TORX SCREW M3 x 6 mm
- 3x QUANTUM SURFACE PLUG (MULTIPORT VERSION)
- QUANTUM SURFACE TANK
Support and Service
In case you need assistance, please contact:
https://www.ekwb.com/customer-support/
EKWB d.o.o.
Pod lipami 18
1218 Komenda
Slovenia - EU