Thank you for purchasing the new UTi80P thermal imager. In order to use this product safely and correctly, please read this manual thoroughly, especially the Safety Instructions part.
After reading this manual, it is recommended to keep the manual at an easily accessible place, preferably close to the device, for future reference.
Limited warranty and liability
Uni-Trend guarantees that the product is free from any defect in material and workmanship within one year from the purchase date. This warranty does not apply to damages caused by accident, negligence, misuse, modification, contamination and improper handling. The dealer shall not be entitled to give any other warranty on behalf of Uni-Trend. If you need warranty service within the warranty period, please contact your seller directly.
Uni-Trend will not be responsible for any special, indirect, incidental or subsequent damage or loss caused by using this device. As some countries or regions do not allow limitations on implied warranties and incidental or subsequent damages, the above limitation of liability may not apply to you.
Table of Contents
1. Introduction
The UTi80P thermal imager is a pocket-sized and lightweight device. This device is able to find hidden hot spots, energy loss, structural defects, pipe jams, HVAC faults and other problems through analyzing the thermal image of a surface. It can measure temperatures up to 400°C and quickly displays the result on the LCD screen. With data recording, analyzing, and report generating functions, the UTi80P is an ideal measurement tool for professional fields requiring temperature analysis.
2. Safety Instructions
To ensure accurate measurement results, please read the instructions carefully.
Please be sure to use this product in accordance with the instructions, otherwise the free warranty will be voided if the product is damaged.
Please do not use this product in flammable, explosive, steamy, wet or corrosive environments.
Please stop using the product if it is damaged or modified to avoid inaccurate test results.
Please use the correct emissivity value in order to obtain accurate temperature readouts.
To ensure the accuracy of the product, please warm it up for 10 minutes before measuring if it has not been used for a long time.
When being charged, the internal temperature of the product will rise, which will lead to inaccurate temperature measurement. So, it is not recommended to be used for testing while or right after the product is being charged.
3. Structure
The UTi80P features the following components:
Item | Description |
---|---|
1 | Left button/Temperature calibration button |
2 | OK/Menu button |
3 | Right button/ Fast thermal tracking toggle |
4 | LCD |
5 | Infrared thermal image window |
6 | USB interface |
7 | Micro SD card slot |
8 | Power button (long press to turn on/off) |
9 | Picture taking/Back button |
4. Display
Display size: 2.4" (49.5mm x 37.7mm)
Display resolution: 320 x 240 pixels
Item | Description |
---|---|
1 | Measured temperature |
2 | Thermal image display area |
3 | Battery level |
4 | "Temperature" option |
5 | "Cursor" option |
6 | "Color palette" option |
7 | "Picture playback" option |
8 | "Settings" option |
6. USB Communication
- Download and install the PC software (refer to UNI-T Documents Download Operation Guide).
- After opening the PC software, connect the USB cable to the computer.
- Users can browse pictures and analyze data through the PC software. Regarding the use of the computer software, users can retrieve the Software User Manual from the Help option of the operation interface.
7. Specifications
Parameter | Value |
---|---|
Temperature range | -10°C~400°C |
Basic accuracy | -10°C~400°C: ±2.0°C or ±2% of reading, whichever is greater (room temperature: 25°C) |
Emissivity | 0.95 default (0.01~0.99 adjustable) |
Measurement resolution | 0.1°C/0.1°F |
Response time | ≤500ms |
IR resolution | 4800 pixels (80*60) |
Pixel size | 17µm |
Color palette | Rainbow, iron red, grey, fast thermal tracking |
Wavelength range | 8μm~14μm |
Field of view (FOV) | 51°(H) * 38°(V) |
Thermal sensitivity | ≤150mk |
Frame rate | ≤9Hz |
Image format | Bitmap (BMP) image (320 x 240 pixels) |
8. Maintenance
Use a wet cloth or weak soap solution to clean the outer shell of the device. Do not use abrasives, isopropyl alcohol or solvents to clean the lens and window.
Note: The inherent temperature drift of the sensor will occasionally cause inaccurate measurement. In this case, press the left button under the temperature measurement interface to bring out "Calibrating" and automatically calibrate the temperature.
9. Appendix
Emissivity of common objects
Material | Emissivity | Material | Emissivity |
---|---|---|---|
Wood | 0.85 | Black paper | 0.86 |
Water | 0.96 | Polycarbonate | 0.8 |
Brick | 0.75 | Concrete | 0.97 |
Stainless steel | 0.14 | Copper oxide | 0.78 |
Tape | 0.96 | Cast iron | 0.81 |
Adhesive tape | 0.09 | Rust | 0.8 |
Copper plate | 0.06 | Gypsum | 0.75 |
Dark aluminum | 0.95 | Paint | 0.9 |
Human skin | 0.98 | Rubber | 0.95 |
Asphalt | 0.96 | Soil | 0.93 |
PVC material | 0.93 |