Aura LED Opti T5 AC G2 Installation Manual
Aura Light
Important Safety Warnings
WARNING! WARNUNG! VARNING! VAROITUS!
Please read the installation instructions carefully and follow them to ensure safety.
The LED tube is only suitable for 50/60 Hz operation.
Only apply in dry indoor environments. Outdoor applications require an IP-rated fixture.
LED lamp must be installed by a professional electrician.
Once installed, do not change any components or structure of the LED lamp.
This lamp is designed for general lighting service (excluding e.g., explosive atmospheres).
Ambient Temperature (TA): -20 °C to 50 °C (-4 °F to 122 °F).
This lamp may not be suitable for all applications where a traditional fluorescent lamp was used. The temperature range is more restricted. Consult the manufacturer if unsure about suitability.
The LED tube is only suitable for direct connection to AC mains 230 V.
Not suitable for use with dimmers.
Product Information
Parts List: LED T5 ECG Compatible Tube, Installation Instructions.
This lamp is designed to replace:
- 549mm: T5 G5 8W
- 1149mm: T5 G5 16W
- 1449mm T5 G5 18.5W
- 1449mm: T5 G5 26W
- 1149mm T5 G5 26W
- 1449mm: T5 G5 37W
Specifications
Length (mm) | Base | Power (W) | Colour temperature (K) | Current (A) |
---|---|---|---|---|
549 | G5 | 8 | 3000/4000/6500 | 0.036A |
1149 | G5 | 16 | 3000/4000/6500 | 0.073A |
1449 | G5 | 18.5 | 3000/4000/6500 | 0.085 A |
1449 | G5 | 26 | 3000/4000/6500 | 0.120 A |
1149 | G5 | 26 | 3000/4000/6500 | 0.120 A |
1449 | G5 | 37 | 3000/4000/6500 | 0.170 A |
Installation Instructions
Step 1: Switch off the electricity.
Ensure the power is disconnected before proceeding. ? ⚡
Step 2: Rotate the lamp 90°.
Rotate the existing lamp by 90 degrees. ? 90°
Step 3: Remove the conventional lamp.
Carefully remove the traditional fluorescent lamp.
Step 4: Insert the LED lamp into the lampholder.
Insert the new LED lamp into the lampholder. ?
Step 5: Secure the position by turning the lamp by 90°.
Turn the LED lamp by 90 degrees to secure its position. ? 90°
Step 6: Switch on electricity.
Reconnect the power supply. ⚡
Step 7: Check that the light switches on.
Verify that the LED lamp is functioning correctly. ✔️
Wiring Diagrams
Single Ended Connection
This connection type works with the following models:
- 549 mm T5 G5 8W
- 1149 mm T5 G5 16W
- 1449 mm T5 G5 18.5W
- 1449 mm T5 G5 26W
- 1149 mm T5 G5 26W
- 1449 mm T5 G5 37W
Diagram description: A single-ended connection shows a 'Driver' and a 'Fuse' connected to 'N' (Neutral) and 'L' (Live) lines. The input is on one side.
Double Ended Connection
This connection type works with the following models:
- 1449 mm T5 G5 26W
- 1149 mm T5 G5 26W
- 1449 mm T5 G5 37W
Diagram description: A double-ended connection shows a 'Driver' and a 'Fuse' connected to 'L' (Live) and 'N' (Neutral) lines. The input can be on either side, but the note specifies the 'printed logo side' for L+N input.
Note: L+N input side = printed logo side.
Safety and Compliance Information
Feature | Description |
---|---|
European Norms Electrical Certification | This product complies with European safety standards. [CE certified] |
Dimming | Dimming not allowed. [No dimming] |
Emergency Operation | Lamp not suitable for emergency operation. [Not for emergency use] |
Environment | Suitable for use only in ventilated environments. [Ventilated environments only] |
Usage Conditions | Lamps to be used in dry conditions or in a luminaire that provides protection. [Dry conditions / Protected luminaire] |
Disposal | Do not dispose of in household waste. Dispose of electrical waste for recycling. [Recycle electrical waste] |