JA-110P PET PIR Motion Detector with Pet Immunity
Product Information and Installation Guide
Product Overview
This document provides information on the JABLOTRON JA-110P PET, a bus system motion detector from JABLOTRON. It is designed for detecting human movement within buildings and features modified detection characteristics with basic immunity to domestic animals. This immunity allows the detector to ignore the movement of small animals weighing up to approximately 25 kg and with a maximum height of 40 cm, preventing false alarms caused by pets.
The detector operates on a pulse reaction basis and occupies a system position. Installation should be performed by a qualified technician holding a valid certificate issued by an authorized distributor.
Installation
[Important] Always switch off the system before connecting the detector to the bus.
- Open the detector cover by pressing the tab (5). Avoid touching the internal PIR sensor (11) to prevent damage.
- Extract the PCB; it is held by a tab (3).
- Drill holes for screws and the cable in the plastic base. The recommended installation height is 2 meters from the floor.
- Insert the bus cable and fix the plastic base to the wall using screws. Ensure the cover tab faces downwards for vertical installation.
- Reinsert the PCB and connect the cables to the terminals (8).
- Proceed according to the control panel installation manual.
- 1 – Holes for flat wall installation
- 2 – Holes for corner installation (in a corner)
- 3 – PCB tab
- 4 – Holes for corner installation (in a corner)
- 5 – Cover tab
- 6 – Red LED – activation
- 7 – Yellow LED – fault
- 8 – Bus terminals
- 9 – Production code
- 10 – Cover tamper sensor
- 11 – PIR sensor
System Assignment and Settings
Consult the control panel manual or recommended software/application for system assignment and settings, depending on the control panel type.
Technical Specifications
Specification | Value | Specification | Value |
---|---|---|---|
Energy | From control panel bus 12 V (8...15 V) | Classification | Grade 2 / II. general indoor (according to EN 50131-1) |
Quiescent current consumption | 5 mA | Operating environment | General indoor |
Maximum current consumption | 10 mA | Operating temperature range | -10 °C to +40 °C |
Recommended installation height | 2 m above floor | Average operating humidity | 75% RH, non-condensing |
Detection angle/coverage | 90° / 12 meters | Certification body | Trezor Test sro (No. 3025), KIWA Nederland bv |
Detection angle/coverage with pet immunity | 90° / 7 meters | Also complies with | EN 50131-1, EN 50131-2-2, EN 50130-4, EN 55032, EN IEC 63000, T 031. |
Dimensions | 60 x 98 x 52 mm | Recommended screw | 2x Ø 3.5 x 40 mm (countersunk head) |
Weight | 75 grams |
Compliance and Declaration
JABLOTRON a.s. declares that the JA-110P PET device conforms to the relevant European Union harmonization legislation: Directives No. 2014/30/EU, 2011/65/EU, when used as intended. The original Declaration of Conformity document is available on the website www.jablotron.com, in the Download section.
The product bears CE and UKCA marks.
Environmental Note
Proper disposal of this product contributes to saving valuable resources and preventing potential negative effects on human health and the environment, which could otherwise arise from inappropriate waste disposal. Please return the product to the retailer or contact the local authority for information on the nearest designated collection point.
Further Information
For an electronic version of this manual (available in other languages) or an installer version for JA-100, scan the QR code provided.