Precautions for Installation and Operation
- Select an installation site capable of supporting at least 5 times the product's weight.
- Do not install in locations with chemicals or oil vapor.
- Use appropriate tools during installation; excessive force or strong impact may damage the product.
- Use only compatible accessories and cameras that meet technical specifications.
- Hanwha Vision does not guarantee the quality of third-party products.
- Clean the product surface with a clean, soft cloth lightly moistened with isopropyl alcohol (IPA) or water.
- Do not install or remove the product during rain or when moisture is present on the exterior.
- Installation must be performed by a qualified person in the electrical field.
- Follow local regulations during installation.
Component List
Note: Accessories may vary by sales country.
Appearance | Quantity | Description |
---|---|---|
Rectangular enclosure with mounting points and a central panel. | 1 | Main body |
Metal bracket with multiple holes for mounting. | 1 | Bracket for installing the main body |
Stack of paper documents. | 1 | User Manual |
Four screws with nuts. | 4 | T20, M4 X L10 For camera installation (Use the double gang) |
Four screws with washers. | 4 | S6, M8 X L25 For mount installation |
Twenty small screws. | 20 | T20, M4 X L8 For installation of internal accessories |
Metal rail with slots. | 1 | DIN35 rail |
Two plastic cable bushings. | 2 | M20 cable bushing for ø5 to 6.5 (Spare part) |
One plastic cable adapter. | 1 | Cable adapter for ø2 to 6 (For a cable gland) |
Two C-shaped metal cable clamps. | 2 | Cable clamp for ~ ø10.6 |
Four C-shaped plastic cable clamps. | 4 | Cable clamp for ~ ø6.8 |
Two C-shaped plastic cable clamps. | 2 | Cable clamp for ~ ø3.3 |
One network cable connector piece. | 1 | Used to connect the network cable |
Overview
Bracket for installing the main body
Diagram showing the mounting bracket with callouts for knock-out holes (M25 and M20), screw holes (ø9 mm), and fixing tabs (M6). An inset shows the sequence for inserting and securing the main body onto the bracket, indicating 'Insert Position', 'Setup Position', and 'Installed Position'.
- Knock-out points: M25 (3/4"), 3 EA; M20 (1/2"), 2 EA
- Main body assembly guide ring: 4 EA
- Screw holes for wall and pole mounting: ø9 mm (0.36"), 6 EA
- Main body fixing tab: M6 (0.24"), 2 EA
Front of main body
Diagram of the cabinet's front panel, indicating locations for door fixing screws (T30), an M16 cable bushing for I/O cables (2-hole), and an M20 cable bushing for LAN cables. It also shows mounting hole patterns (M8 and M4) with dimensions (86 x 130mm).
- Door fixing screw: T30, 4 EA
- M16 cable bushing: 2-hole for I/O cable
- M20 cable bushing: for LAN cable
- Mounting holes: M8 (0.32"), 4 EA (86 x 130mm); M4 (0.16"), 4 EA/EACH (Double gang)
Inside the main body
Diagram of the cabinet's interior, highlighting the door movement range (0 to 105 degrees). Features include a Din35 rail structure, M25 drill-out points, M20 cable bushings (for ø5 to 6.5mm), an M16 cable gland (for ø4.5 to 10mm), main body fixing screws (T30), cut-out points (M25, M20), and an air vent.
- Din35 structure
- M25 drill-out: 1 EA
- M20 cable bushing: 3 EA for ø5 to 6.5
- Main body fixing screw: T30, 2 EA
- M16 cable gland: 2 EA for ø4.5 to 10
- Cut-out points: M25 (3/4"), 3 EA; M20 (1/2"), 2 EA
- Air vent: ⚠️ Do not touch the air vent to prevent damage.
Installation
Step 1: Bracket Preparation
Diagram showing the bracket dimensions and knock-out locations. The bracket measures 3-192mm (7.68").
- Screw holes for wall and pole mounting: ø9 mm (0.36"), 6 EA.
- Dimensions for spacing: 2-105mm (4.20"); 2-105mm (4.20"); 5-95mm (3.8").
- Knock-out points: M25 (3/4"), 3 EA; M20 (1/2"), 2 EA (repeated for two sets of knock-outs).
- Instructions: Remove knock outs for floor or wall as needed.
Step 2: Mounting the Bracket
Diagrams illustrating how to mount the bracket.
- Installing on wall: Shows the bracket being attached to a wall using screws (indicated as 'Not included').
- Installing on pole mount: Shows the bracket being attached to a pole using screws (indicated as 'Included on pole mount').
Step 3: Attaching the Cabinet to the Bracket
Diagram showing the cabinet being attached to the mounted bracket. It involves aligning and sliding the cabinet onto the bracket's mounting points. An inset shows the 'Insert Position' and 'Setup Position' for the locking mechanism.
Step 4: Securing the Cabinet
Diagram showing the cabinet being secured to the bracket. The cabinet is shown with its door open, and screws are being inserted into the mounting points.
- Securing screws: T30, x4.
Cable Connection
Precautions:
- Electrical cables must be installed by a qualified person, following local regulations.
- Connect the power supply from the main supply after installation.
- Separate and tidy signal or power cables using provided cable clamps.
- Keep unused cable glands and bushings in factory condition to maintain IP rating and prevent moisture ingress.
- Cable entry direction for bushings must be from outside to inside.
- The two-hole bushings on the front are not compatible with the Cap Installer; use the cut-and-connect method instead.
Cable Entry Details:
- M25 drill-out points are available.
- The diameter of cables passing through M16 cable glands must be ø4.5 to 10 mm (0.18" to 0.4").
- When using the provided cable adapter, the passing cable diameter must be ø2 to 6 mm (0.08" to 0.24").
- M20 cable bushings are available for ø5 to 6.5mm (0.2" to 0.26").
Cap Installer Guide:
- ⚠️ Do not route the bushing with the cable from inside to outside; no quality guarantee is provided for this method.
- Ensure the bushing is correctly installed inside the product.
- Diagrams show correct (✔️) and incorrect (❌) cable routing through bushings, with checkmarks and crosses indicating proper installation.
Step 5: Final Cabinet Attachment
This step reiterates the sliding mechanism shown in Step 3, with numbered indicators for the sequence.
Step 6: Closing and Initial Securing
Diagram showing the cabinet door being closed and initially secured.
- Torque specification: 2.0N.m (1.4lb.ft)
- Screws: T30, x2.
Step 7: Final Tightening
Diagram showing the final tightening of screws on the cabinet exterior.
- Torque specification: 2.0N.m (1.4lb.ft)
- Screws: T30, x4.
Camera Installation
Instructions for installing a camera onto the cabinet.
- ⚠️ Be sure to install the camera or other items with the door closed.
- ⚠️ Do not leave the door open for a long time with the camera or other items mounted.
- Diagrams show the process of attaching a camera mount and then the camera.
Mount Installation
Instructions for installing a mount onto the cabinet.
- Diagrams show the process of attaching a mount to the cabinet's front panel.
Regulatory and Distributor Information
EAC Mark: Indicates compliance with Eurasian Economic Union technical regulations.
Russian Text: Subject to intended use under normal conditions. Service life: 7 years.
Turkey Distributors:
- EDS Elektronik Destek Sanayi ve Ticaret Ltd. Şti.
Meclis Mah. Teraziler Cad. Hayran Sk. (Eskisi Kılıç Sk.) No: 4 Sancaktepe / İstanbul / Türkiye
Tel: +90.216.313.25.15 - ENTES ELEKTRONİK CİHAZLAR İMALAT VE TİC. A.Ş.
Dudullu Org.San.Bölg. 1. Cad. No:23 34776 Ümraniye / İstanbul / Türkiye
Tel: +90.216.313.01.10 - TEKNOMAKS TEKNOLOJI / TEKNOMAKS BİLİŞİM
MERDİVENKÖY MAH.DİKYOL SOK. BUSINESS İSTANBUL No:2, Kat:7, D:B67, 34732 Kadıköy / İstanbul / Türkiye
Tel: +90.212.217.54.22
Statements regarding average service life recommended by the Ministry of Trade and compliance with EEE regulations are also present.