Hanwha Vision SBP-150NBW Cabinet User Manual

This document provides comprehensive instructions for the installation and operation of the Hanwha Vision SBP-150NBW Cabinet.

Copyright and Disclaimer

Copyright ©2024 Hanwha Vision Co., Ltd. All rights reserved.

Trademark All trademarks mentioned herein are registered trademarks of their respective companies.

Restriction This document is protected by copyright. Reproduction, distribution, or modification without formal authorization is prohibited.

Disclaimer Hanwha Vision strives for accuracy but provides no formal guarantee. Use of this document and its results is at the user's own responsibility. Hanwha Vision reserves the right to change content without prior notice. Design and specifications are subject to change without prior notice.

Precautions for Installation and Operation

  • Select an installation site capable of supporting at least 5 times the product's weight.
  • Do not install in locations with chemicals or oil vapor.
  • Use appropriate tools during installation; excessive force or strong impact may damage the product.
  • Use only compatible accessories and cameras that meet technical specifications.
  • Hanwha Vision does not guarantee the quality of third-party products.
  • Clean the product surface with a clean, soft cloth lightly moistened with isopropyl alcohol (IPA) or water.
  • Do not install or remove the product during rain or when moisture is present on the exterior.
  • Installation must be performed by a qualified person in the electrical field.
  • Follow local regulations during installation.

Component List

Note: Accessories may vary by sales country.

AppearanceQuantityDescription
Rectangular enclosure with mounting points and a central panel.1Main body
Metal bracket with multiple holes for mounting.1Bracket for installing the main body
Stack of paper documents.1User Manual
Four screws with nuts.4T20, M4 X L10 For camera installation (Use the double gang)
Four screws with washers.4S6, M8 X L25 For mount installation
Twenty small screws.20T20, M4 X L8 For installation of internal accessories
Metal rail with slots.1DIN35 rail
Two plastic cable bushings.2M20 cable bushing for ø5 to 6.5 (Spare part)
One plastic cable adapter.1Cable adapter for ø2 to 6 (For a cable gland)
Two C-shaped metal cable clamps.2Cable clamp for ~ ø10.6
Four C-shaped plastic cable clamps.4Cable clamp for ~ ø6.8
Two C-shaped plastic cable clamps.2Cable clamp for ~ ø3.3
One network cable connector piece.1Used to connect the network cable

Overview

Bracket for installing the main body

Diagram showing the mounting bracket with callouts for knock-out holes (M25 and M20), screw holes (ø9 mm), and fixing tabs (M6). An inset shows the sequence for inserting and securing the main body onto the bracket, indicating 'Insert Position', 'Setup Position', and 'Installed Position'.

  • Knock-out points: M25 (3/4"), 3 EA; M20 (1/2"), 2 EA
  • Main body assembly guide ring: 4 EA
  • Screw holes for wall and pole mounting: ø9 mm (0.36"), 6 EA
  • Main body fixing tab: M6 (0.24"), 2 EA

Front of main body

Diagram of the cabinet's front panel, indicating locations for door fixing screws (T30), an M16 cable bushing for I/O cables (2-hole), and an M20 cable bushing for LAN cables. It also shows mounting hole patterns (M8 and M4) with dimensions (86 x 130mm).

  • Door fixing screw: T30, 4 EA
  • M16 cable bushing: 2-hole for I/O cable
  • M20 cable bushing: for LAN cable
  • Mounting holes: M8 (0.32"), 4 EA (86 x 130mm); M4 (0.16"), 4 EA/EACH (Double gang)

Inside the main body

Diagram of the cabinet's interior, highlighting the door movement range (0 to 105 degrees). Features include a Din35 rail structure, M25 drill-out points, M20 cable bushings (for ø5 to 6.5mm), an M16 cable gland (for ø4.5 to 10mm), main body fixing screws (T30), cut-out points (M25, M20), and an air vent.

  • Din35 structure
  • M25 drill-out: 1 EA
  • M20 cable bushing: 3 EA for ø5 to 6.5
  • Main body fixing screw: T30, 2 EA
  • M16 cable gland: 2 EA for ø4.5 to 10
  • Cut-out points: M25 (3/4"), 3 EA; M20 (1/2"), 2 EA
  • Air vent: ⚠️ Do not touch the air vent to prevent damage.

Installation

Step 1: Bracket Preparation

Diagram showing the bracket dimensions and knock-out locations. The bracket measures 3-192mm (7.68").

  • Screw holes for wall and pole mounting: ø9 mm (0.36"), 6 EA.
  • Dimensions for spacing: 2-105mm (4.20"); 2-105mm (4.20"); 5-95mm (3.8").
  • Knock-out points: M25 (3/4"), 3 EA; M20 (1/2"), 2 EA (repeated for two sets of knock-outs).
  • Instructions: Remove knock outs for floor or wall as needed.

Step 2: Mounting the Bracket

Diagrams illustrating how to mount the bracket.

  • Installing on wall: Shows the bracket being attached to a wall using screws (indicated as 'Not included').
  • Installing on pole mount: Shows the bracket being attached to a pole using screws (indicated as 'Included on pole mount').

Step 3: Attaching the Cabinet to the Bracket

Diagram showing the cabinet being attached to the mounted bracket. It involves aligning and sliding the cabinet onto the bracket's mounting points. An inset shows the 'Insert Position' and 'Setup Position' for the locking mechanism.

Step 4: Securing the Cabinet

Diagram showing the cabinet being secured to the bracket. The cabinet is shown with its door open, and screws are being inserted into the mounting points.

  • Securing screws: T30, x4.

Cable Connection

Precautions:

  • Electrical cables must be installed by a qualified person, following local regulations.
  • Connect the power supply from the main supply after installation.
  • Separate and tidy signal or power cables using provided cable clamps.
  • Keep unused cable glands and bushings in factory condition to maintain IP rating and prevent moisture ingress.
  • Cable entry direction for bushings must be from outside to inside.
  • The two-hole bushings on the front are not compatible with the Cap Installer; use the cut-and-connect method instead.

Cable Entry Details:

  • M25 drill-out points are available.
  • The diameter of cables passing through M16 cable glands must be ø4.5 to 10 mm (0.18" to 0.4").
  • When using the provided cable adapter, the passing cable diameter must be ø2 to 6 mm (0.08" to 0.24").
  • M20 cable bushings are available for ø5 to 6.5mm (0.2" to 0.26").

Cap Installer Guide:

  • ⚠️ Do not route the bushing with the cable from inside to outside; no quality guarantee is provided for this method.
  • Ensure the bushing is correctly installed inside the product.
  • Diagrams show correct (✔️) and incorrect (❌) cable routing through bushings, with checkmarks and crosses indicating proper installation.

Step 5: Final Cabinet Attachment

This step reiterates the sliding mechanism shown in Step 3, with numbered indicators for the sequence.

Step 6: Closing and Initial Securing

Diagram showing the cabinet door being closed and initially secured.

  • Torque specification: 2.0N.m (1.4lb.ft)
  • Screws: T30, x2.

Step 7: Final Tightening

Diagram showing the final tightening of screws on the cabinet exterior.

  • Torque specification: 2.0N.m (1.4lb.ft)
  • Screws: T30, x4.

Camera Installation

Instructions for installing a camera onto the cabinet.

  • ⚠️ Be sure to install the camera or other items with the door closed.
  • ⚠️ Do not leave the door open for a long time with the camera or other items mounted.
  • Diagrams show the process of attaching a camera mount and then the camera.

Mount Installation

Instructions for installing a mount onto the cabinet.

  • Diagrams show the process of attaching a mount to the cabinet's front panel.

Regulatory and Distributor Information

EAC Mark: Indicates compliance with Eurasian Economic Union technical regulations.

Russian Text: Subject to intended use under normal conditions. Service life: 7 years.

Turkey Distributors:

  • EDS Elektronik Destek Sanayi ve Ticaret Ltd. Şti.
    Meclis Mah. Teraziler Cad. Hayran Sk. (Eskisi Kılıç Sk.) No: 4 Sancaktepe / İstanbul / Türkiye
    Tel: +90.216.313.25.15
  • ENTES ELEKTRONİK CİHAZLAR İMALAT VE TİC. A.Ş.
    Dudullu Org.San.Bölg. 1. Cad. No:23 34776 Ümraniye / İstanbul / Türkiye
    Tel: +90.216.313.01.10
  • TEKNOMAKS TEKNOLOJI / TEKNOMAKS BİLİŞİM
    MERDİVENKÖY MAH.DİKYOL SOK. BUSINESS İSTANBUL No:2, Kat:7, D:B67, 34732 Kadıköy / İstanbul / Türkiye
    Tel: +90.212.217.54.22

Statements regarding average service life recommended by the Ministry of Trade and compliance with EEE regulations are also present.

Models: SBP-150NBW Aluminum Cabinet, SBP-150NBW, Aluminum Cabinet, Cabinet

PDF preview unavailable. Download the PDF instead.

Manuals SBP-150NBW 250822 EN Adobe PDF Library 17.0 Adobe InDesign 19.3 (Windows)

Related Documents

Preview Hanwha Vision SBP-215HMW Hanging Mount: Product Overview and Installation Guide
Discover the Hanwha Vision SBP-215HMW hanging mount, a versatile accessory for compatible security cameras. This guide provides a product overview and essential installation precautions.
Preview Hanwha Vision SBP-250WMW Wall & Pole Mount Installation Guide
Official installation guide for the Hanwha Vision SBP-250WMW Wall & Pole Mount, detailing package contents, mounting procedures, and precautions for secure camera installation.
Preview Hanwha Vision SBP-300WM Wall Mount Adaptor Installation Guide
Detailed installation guide for the Hanwha Vision SBP-300WM Wall Mount Adaptor, including product overview, safety precautions, step-by-step instructions, and technical specifications for security camera installations.
Preview Hanwha Vision QNF-C9010: Telecamera Fisheye IA 12 MP - Specifiche Tecniche
Scheda tecnica dettagliata per la telecamera di sicurezza Hanwha Vision QNF-C9010, una telecamera fisheye IA da 12 MP con analisi video avanzate, visione notturna e supporto PoE. Include specifiche tecniche, caratteristiche operative e certificazioni.
Preview Hanwha Vision SBP-276HM/SBP-276HMW Hanging Mount Adaptor Installation Guide
Installation instructions and specifications for the Hanwha Vision SBP-276HM and SBP-276HMW Hanging Mount Adaptors, designed for use with PNM-9000VQ and PNM-9084QZ cameras and compatible mount adaptors.
Preview SBC-140WB Installation Guide | Hanwha Vision
Official installation instructions for the Hanwha Vision SBC-140WB network camera accessory. Learn how to properly attach and secure the device cover.
Preview Hanwha Vision SBP-125WMW Wall Mount Installation Guide
Comprehensive guide for installing the Hanwha Vision SBP-125WMW Wall Mount, including features, precautions, installation steps, and specifications.
Preview Hanwha Vision Industrial Cyber Security Capability Certificate of Conformity
Official Certificate of Conformity for Hanwha Vision's Industrial Cyber Security Capability, assessed against IEC 62443-4-1:2018. Details include applicant information, standard compliance, security requirements, and maturity level.