Moving Head 19x15W ZOOM User Manual

Model: P7100550

1. Introduction

Thank you for purchasing the Moving Head 19x15W ZOOM. For safety reasons and to ensure trouble-free operation, please read these instructions carefully.

2. Safety Information

Please keep this User Manual for future consultation. If you sell the fixture to another user, ensure they also receive this instruction booklet.

WARNING!

The Moving Head 19x15W ZOOM has a powerful pan motor. The torque reaction when the head is panned suddenly can cause the base to move if the fixture is standing unsecured on a surface. Do not apply power to the Moving Head 19x15W ZOOM unless the base is securely fastened to a surface or to rigging hardware.

Use 2 clamps to rig the fixture. Do not hang the fixture from only one clamp. Lock each clamp with both 1/4-turn fasteners. Fasteners are locked only when turned a full 90° clockwise.

When clamping the fixture to a truss or other structure at an angle other than with the yoke hanging vertically downwards, use two clamps of half-coupler type. Do not use any type of clamp that does not completely encircle the structure when fastened.

Position or shade the head so that the front lens is not exposed to sunlight or any other strong light source from any angle, even for a few seconds. The Moving Head 19x15W ZOOM lens can focus the sun's rays, creating a potential fire hazard and causing damage.

IMPORTANT!

Do not point strong light output from other fixtures at the Moving Head 19x15W ZOOM, as intense illumination can damage the display.

Figure 2 Description: Lenses can focus sunlight and strong light, presenting a risk of fire and damage to the fixture. Shield or shade the head if necessary.

3. Product Information

4. Installation

The unit should be mounted via its screw holes on the bracket. Always ensure that the unit is firmly fixed to avoid vibration and slipping while operating. Always ensure that the structure to which you are attaching the unit is secure and is able to support a weight of 10 times of the unit's weight.

Also, always use a safety cable that can hold 12 times of the weight of the unit when installing the fixture. The equipment must be fixed by professionals. It must be fixed at a place that is out of the touch of people and where no one passes by or under it.

Upon removing the unit from its packaging, check for any damage incurred during transport. Before connecting to the electrical mains, ensure the unit is securely mounted. The manufacturer is not responsible for damage caused by unstable mounting.

During operation, ensure correct connection to the electrical mains and proper grounding. Verify that the electrical mains parameters comply with the device requirements. All operations involving connecting the device to the electrical mains should be performed by qualified personnel.

The unit should be installed in a well-ventilated area, at least 15cm from the nearest surface (wall, ceiling, etc.). Simultaneously, ensure that ventilation openings are not blocked and that fans are operating correctly.

5. Connection

Interfaces:

5.1 Connecting DMX Signal:

The connection is performed using a cable with XLR-female to XLR-Male plugs.

CAUTION!

At the last fixture, the DMX signal must be terminated with a terminator. Solder a 120Ω resistor between signal (-) and signal (+) into an XLR plug and plug it into the DMX output of the last fixture.

DMX Connection Diagram Description: A DMX controller connects to DMX 512 fixtures using XLR cables. The XLR connectors have the following pinout: Pin 1: Ground, Pin 2: DMX+, Pin 3: DMX-.

5.2 Voltage Specification:

Input VoltageTotal PowerFrequency
100~245V300W50/60Hz

5.3 Connecting Power Supply:

The connection is performed using a power cable with a PowerCon connector (included). The device must be operated by qualified personnel. Ensure that the power grid supply parameters are consistent with the device parameters and limitations are not exceeded.

CAUTION!

In case of cable damage, do not attempt to repair it yourself. Replacement or repair can only be made by the manufacturer or by a person with appropriate permissions.

When using the lamp, the change rate of power voltage should be within ±10%. If the voltage is too high, it will shorten the light's life; if it's not enough, the lamp will be dark. Please restart it after turning the light off for 20 minutes until full-cooling. Frequent switching will reduce the lifespan of lamps and bulbs; intermittent using will improve the life of bulbs and lamps.

6. Setting Interface

System Settings:

Operation Mode:

Factory Setup:

SettingValue
X axis calibration128
Y axis calibration128
Focusing calibration128
Red220
Green220
Blue220
White220
Logo to choose000

7. DMX Channels Setting

16 CH Mode:

ChannelFunction
1Pan
2Tilt
3P/T Speed
4Dimmer
5Red (R) group 1
6Green (G) group 1
7Blue (B) group 1
8White (W) group 1
9Strobo
10Zoom
11Function mode
12Functional mode speed
13Pan Fine
14Tilt Fine
15Rest(255)
16Empty

24 CH Mode:

ChannelFunction
1Pan
2Tilt
3P/T Speed
4Dimmer
5Red (R) group 1
6Green (G) group 1
7Blue (B) group 1
8White (W) group 1
9Red (R) group 2
10Green (G) group 2
11Blue (B) group 2
12White (W) group 2
13Red (R) group 3
14Green (G) group 3
15Blue (B) group 3
16White (W) group 3
17Strobo
18Zoom
19Function mode
20Functional mode speed
21Pan Fine
22Tilt Fine
23Rest(255)
24Empty
Models: P7100550 Moving Head 19x15 Zoom, P7100550, Moving Head 19x15 Zoom, Moving Head, Head

File Info : application/pdf, 16 Pages, 1.30MB

PDF preview unavailable. Download the PDF instead.

F7100550-Moving-Heads-ZOOM-19x15W-3-Section-PL-EN

References

Adobe PDF Library 16.0.5 Adobe InDesign 17.1 (Windows)

Related Documents

Preview Flash Moving Head 19x15W ZOOM User Manual
User manual for the Flash Moving Head 19x15W ZOOM, covering introduction, safety information, product details, installation, connections, DMX settings, and channel functions.
Preview Flash Moving Head 19x15W Big Eye User Manual
Comprehensive user manual for the Flash Moving Head 19x15W Big Eye, covering safety, installation, connections, DMX channel configurations, and menu operations. Includes technical specifications and operational guidelines.
Preview FLASH LED Moving Head Beam 80W User Manual
Comprehensive user manual for the FLASH LED Moving Head Beam 80W (Model F7100518). Covers product introduction, safety information, specifications, installation, connection, DMX channel functions, and operational modes. Visit www.flash-butrym.pl for more.
Preview Flash Moving Head 12R User Manual
Comprehensive user manual for the Flash Moving Head 12R, detailing product information, safety guidelines, installation, connection, and DMX charts. Includes technical specifications and operational instructions for professional lighting applications.
Preview FLASH MH-BEAM 8R User Manual: Installation, Operation, and DMX Control
Comprehensive user guide for the FLASH MH-BEAM 8R moving head stage lighting fixture. Covers safety, installation, product specifications, and detailed DMX channel mapping for professional event lighting.
Preview FLASH StrobeFX 1000 IP65 User Manual
Comprehensive user manual for the FLASH StrobeFX 1000 IP65 lighting fixture, detailing safety instructions, unpacking, installation, connection, DMX charting, menu overview, technical drawings, photometric data, and specifications.
Preview Flash LED Moving Head 60W Spot User Manual
User manual for the Flash LED Moving Head 60W Spot, providing safety information, product details, installation, connection, and DMX channel configurations.
Preview Flash LED PAR 64 18x15W 6in1 RGBWA+UV Zoom IP65 User Manual
User manual for the Flash LED PAR 64 18x15W 6in1 RGBWA+UV Zoom IP65 lighting fixture. Provides detailed information on safety precautions, product specifications, installation guidelines, connection methods, and DMX channel configurations.