Flash LED PAR 64 18x15W 6in1 RGBWA+UV Zoom IP65

Thank you for purchasing the LED PAR 64 18x15W 6in1 RGBWA+UV Zoom IP65. For safety reasons and to ensure trouble-free operation, carefully read these instructions.

Safety Information

  • Keep this User Manual for future consultation. If you sell the fixture to another user, ensure they also receive this booklet.
  • Unpack and check carefully for transportation damage before using the fixture.
  • Before operating, ensure that the voltage and frequency of power supply match the fixture's requirements.
  • It is important to ground the yellow/green conductor to earth to avoid electric shock.
  • Disconnect main power before servicing and maintenance.
  • Use a safety chain when fixing this fixture.
  • Do not handle the fixture by its head only; always handle it by its base.
  • Do not use the device in high humidity conditions. Use between -10°C to +35°C.

Warnings

  • In case of serious operating problems, stop using the fixture immediately. Never attempt to repair the fixture yourself. Repairs by unskilled people can lead to damage or malfunction. Contact the nearest authorized technical assistance center. Always use the same type of spare parts.
  • Do not connect the device to any dimmer pack.
  • Do not touch any wire during operation, as there is a hazard of electric shock.
  • To prevent or reduce the risk of electrical shock or fire, do not expose the fixture to rain or moisture.
  • The housing must be replaced if it is visibly damaged.
  • Do not look directly at the LED light spot while the fixture is on.
  • The device must be connected to the power supply to avoid condensation.
  • The LED PAR 64 has a powerful pan motor. The torque reaction when the head is panned suddenly can cause the base to move if the fixture is standing unsecured on a surface. Do not apply power unless the base is securely fastened to a surface or rigging hardware.
  • Use 2 clamps to rig the fixture. Do not hang the fixture from only one clamp. Lock each clamp with both 1/4-turn fasteners. Fasteners lock when turned a full 90° clockwise.
  • When clamping the fixture to a truss or structure at an angle other than with the yoke hanging vertically downwards, use two clamps of half-coupler type. Do not use any clamp that does not completely encircle the structure when fastened.
  • Position or shade the head so that the front lens is not exposed to sunlight or any other strong light source from any angle, even for a few seconds. The LMH 150W Spot lens can focus sun's rays, creating a potential fire hazard and causing damage.
  • Do not point strong light output from other fixtures at the LED PAR 64, as intense illumination can damage the display.

Figure 2 illustrates how lenses can focus sunlight and strong light, presenting a risk of fire and damage to the fixture. Shield or shade the head if necessary.

Product Information

  • Light: 18pcs 15W 6in1 RGBWA+UV LED
  • Control: DMX 512/Auto/Main-fllow, Sound control with adjustable sensitivity
  • Features: Fast zoom effect
  • Housing: Extruded aluminum par housing
  • Waterproof Rating: IP65
  • DMX Modes: 11 and 7 DMX channel modes

Specifications

ParameterValue
3-Pin XLR DMX Input/OutputYes
Power Supply110/240V AC, 50-60Hz
Power Consumption180 W
Net Weight9.2 kg
Dimensions (Fixture)H(24)xW(31)xD(31) cm
Dimensions (Box)H(37)xW(32)xD(32) cm
Weight (Case)10 kg

Installation

The unit should be mounted via its screw holes on the bracket. Always ensure that the unit is firmly fixed to avoid vibration and slipping while operating. Always ensure that the structure to which you are attaching the unit is secure and is able to support a weight of 10 times of the unit's weight. Also, always use a safety cable that can hold 12 times the weight of the unit when installing the fixture. The equipment must be fixed by professionals and placed where it is out of reach of people and where no one passes by or under it.

Connection

Interfaces

  • DMX (in/out): XLR 3(5)-pin socket
  • Power (in/out): powerCON socket

Connecting DMX Signal

Connection is performed using a cable with XLR-female to XLR-Male plugs.

3-Pin XLR Pinout

Female XLR: Pin 1: Ground, Pin 2: DMX +, Pin 3: DMX -

Male XLR: Pin 1: Ground, Pin 2: DMX +, Pin 3: DMX -

5-Pin XLR Pinout

Female XLR: Pin 1: Ground, Pin 2: DMX -, Pin 3: DMX +, Pin 4: Not used, Pin 5: Not used

Male XLR: Pin 1: Ground, Pin 2: DMX -, Pin 3: DMX +, Pin 4: Not used, Pin 5: Not used

Caution: At the last fixture, the DMX signal must be terminated with a terminator. Solder a 120Ω resistor between signal (-) and signal (+) into an XLR plug and plug it into the DMX output of the last fixture.

Diagram shows a DMX Controller connected to multiple DMX 512 fixtures.

Power Supply Connection

Voltage Specification

Input VoltageTotal PowerFrequency
110/240V180W50/60Hz

Connection is performed using a power cable with a PowerCON connector (included). The device must be operated by qualified personnel. Make sure that the power grid supply parameters are consistent with device parameters and limitations are not exceeded.

Caution: In case of cable damage, do not attempt to repair. Replacement or repair can only be made by the manufacturer or a person with appropriate permissions.

Note on Voltage and Lamp Life: The change rate of power voltage should be within ±10%. If the voltage is too high, it will shorten the light's life; if it's not enough, the lamp will be dark. Please restart the fixture after turning it off for 20 minutes until full cooling. Frequent switching will reduce the lifespan of lamps and bulbs; intermittent use will improve the life of bulbs and lamps.

DMX Channels

11 CH Mode

CHFunctionValueDescription
1Zoom0-255Zoom
2Whole Dimmer0-255Whole Dimmer
3Strobe0-9Empty
10-255From Slow to Fast
4Function0-9Dimmer
10-19Red
20-29Green
30-39Blue
40-49R-G
50-59R-B
60-69G-B
70-79R-G-B
80-89Orange
90-149Gradual change
150-199Pulse change
200-229Jump change
230-255Sound control
5Function speed0-255From Slow to Fast
6Red0-255From Faint to Brightness
7Green0-255From Faint to Brightness
8Blue0-255From Faint to Brightness
9White0-255From Faint to Brightness
10Amber0-255From Faint to Brightness
11UV Color0-255From Faint to Brightness

7 CH Mode

CHFunctionValueDescription
1Zoom0-255Zoom
2Red0-255Red from Faint to Brightness
3Green0-255Green from Faint to Brightness
4Blue0-255Blue from Faint to Brightness
5White0-255White from Faint to Brightness
6Amber0-255Amber from Faint to Brightness
7UV0-255UV from Faint to Brightness
Models: IP65, LED Par 64 18x15W 6-In-1 RGBWA UV Zoom

File Info : application/pdf, 12 Pages, 1.19MB

PDF preview unavailable. Download the PDF instead.

F7100323-LED-PAR-64-18x15W-6in1-RGBWA-UV-Zoom-IP65-EN PL Adobe PDF Library 15.0 Adobe InDesign 16.3 (Windows)

Related Documents

PreviewFLASH LED PAR 18x15W RGBWA+UV IP65 User Manual
User manual for the FLASH LED PAR 18x15W RGBWA+UV IP65 lighting fixture, covering introduction, safety information, product details, installation, connections, voltage specifications, and DMX channels.
PreviewFLASH LED PAR 64 18x12 RGBWA+UV FLAT User Manual
User manual for the FLASH LED PAR 64 18x12 RGBWA+UV FLAT lighting fixture, providing detailed information on safety, product specifications, installation, connection, and DMX control.
PreviewFlash LED PAR 36 12W RGB User Manual
User manual for the Flash LED PAR 36 12W RGB lighting fixture, detailing its features, safety precautions, installation, connection methods, and DMX channel configurations.
PreviewFlash Series DJ LED PAR 64 18x12 RGBWA+UV FLAT User Manual
User manual for the Flash Series DJ LED PAR 64, featuring 18x12W RGBWA+UV LEDs. Includes safety information, product specifications, installation, connection, and DMX charts.
PreviewFLASH parACCU 320 WDMX SET8 User Manual
User manual for the FLASH parACCU 320 WDMX SET8 DJ lighting fixture. Provides detailed information on product specifications, safety guidelines, menu operation, DMX control, and remote control functions.
PreviewFlash Moving Head 19x15W ZOOM User Manual
Comprehensive user manual for the Flash Moving Head 19x15W ZOOM (Model P7100550), covering safety precautions, product information, installation, connection, setting interface, and DMX channel configurations.
PreviewFlash Moving Head 19x15W Big Eye User Manual
Comprehensive user manual for the Flash Moving Head 19x15W Big Eye, covering safety, installation, connections, DMX channel configurations, and menu operations. Includes technical specifications and operational guidelines.
PreviewFLASH MH-BEAM 8R User Manual: Installation, Operation, and DMX Control
Comprehensive user guide for the FLASH MH-BEAM 8R moving head stage lighting fixture. Covers safety, installation, product specifications, and detailed DMX channel mapping for professional event lighting.