BOT-R3W Wi-Fi Gas Boiler Thermostat Manual
Application
The BOT-R3W intelligent thermostat is a temperature controller suitable for gas wall-mounted boilers used in underfloor heating systems. By comparing the ambient temperature with the set temperature, it controls the working status of the wall-mounted boiler to achieve the goals of regulating ambient temperature, ensuring comfort, and saving energy.
Electrical Specifications
Specification | Value |
---|---|
Equipment power supply | 3 × 1.5V alkaline AA batteries |
Protection grade | IP20 |
Temperature sensor | NTC |
Temperature Accuracy | ±0.5°C (adjustable) |
Self consumption power | <170uA |
LOAD | 3A (resistive) |
Operating Instructions
Power On/Off: Press the power on/off button [▶️] once to turn on the machine; press it again to turn off the machine, and simultaneously close all valves.
Mode Conversion Key (M): When the device is powered on, press the M key [M] to switch the working mode. The liquid crystal display indicates manual mode [M], indicates "away from home" mode [?]. (For the online version, automatic mode can be set via your mobile device). The liquid crystal display indicates automatic mode [?].
Adjustment Keys: When the device is turned on, press the [▲/▼ keys] to adjust the temperature and other parameters.
Child Lock Function: Press and hold the [▲/▼ keys] for 5 seconds while the device is turned on. When the panel enters the lock state, a lock icon [?] appears on the right side of the display screen, indicating that the lock key has been successfully pressed.
Unlock: Press and hold the [▲/▼ keys] for 5 seconds to unlock the child lock on the panel.
Temporary Mode: When the device is powered on, click the [TEMP] button. If it is in automatic mode, it will switch to the temporary mode. You can then directly adjust the set temperature.
Device Network Connection Settings
When the temperature controller transmitter panel is turned on, long press the [▲ key] for 5 seconds until the Wi-Fi icon [?] flashes on the display screen, and the temperature controller enters the connected state.
Open the Tuya Smart/Smart Life app.
In the small appliance list, find the (Bluetooth + WIFI) thermostat. Under the specified setup, click "Confirm", choose a 2.4GHz Wi-Fi network, enter its password, click "Next", follow the prompts to click "Go to Connect", click the indicated content, and return to the Tuya APP to set up the network.
Wiring Diagram
The diagram illustrates the connections for NO, COM, and NC terminals. It notes that for passive linkage of wall-mounted furnaces, the COM and NO ports are used. A crucial note advises that due to the strong power design of some circuits in this product, installation must be performed by professionals.
Connections:
- NO (Normally Open)
- COM (Common)
- NC (Normally Closed)
The diagram shows a connection from the Boiler to these terminals.
Equipment Icon Description
- Wi-Fi Icon [?]: Indicates Wi-Fi connectivity status.
- Real-time Temperature: Displays the current ambient temperature.
- Set Temperature: Displays the target temperature.
- Power On/Off Button [▶️]: Used to turn the device on or off.
- Mode Key [M]: Used to switch between operating modes (Manual, Away, Auto).
- Device Output Icon [?]: Indicates the device's operational status (e.g., heating/cooling).
- Antifreeze Function Icon [❄️]: Indicates the antifreeze function is active.
- Cooling Icon [❄️]: Indicates the device is in cooling mode.
- Heating Icon [?]: Indicates the device is in heating mode.
- Child Lock Icon [?]: Indicates the child lock feature is active.
- Device Battery Icon [?]: Shows the battery level.
Advanced Device Options Settings
When the device is powered off, press and hold the M key for 5 seconds to enter the advanced option settings. Press the M key to switch to the next item, and use the [▲/▼ keys] to make adjustments.
Display | Parameter | Default Value | Parameter Function |
---|---|---|---|
1 | Temperature display | 0 | Temperature compensation range: -9.9~9.9°C |
2 | Manual mode | 0.5 | Temperature difference startup range: 0.5~10 |
3 | Antifreeze function | ON | Turn on/off the device's antifreeze function |
4 | Set upper temperature limit value | 35°C | Adjustable range: 15°C~60°C |
5 | Key sound | ON | Turn on/off device button sound |
6 | Cooling/Heating | * Cooling Heating * | Select Cooling or Heating mode |
7 | Restore device factory settings | "-" | Press the M key to adjust display to "-", then press the confirm key to restore factory settings. |
Daily Programming Time Slot
The network programming mode needs to be operated via the APP and works in six cycles per day. (The single machine version does not have a programming function).
Serial Number | Time Slot | Set Temperature | Key |
---|---|---|---|
1 | 06:00 | 20°C | [Key Icon] |
2 | 08:00 | 16°C | [Key Icon] |
3 | 11:30 | 16°C | [Key Icon] |
4 | 12:30 | 16°C | [Key Icon] |
5 | 17:00 | 22°C | [Key Icon] |
6 | 22:00 | 16°C | [Key Icon] |
Low-Temperature Protection Function
The thermostat is in the off state. When the indoor temperature drops below 5 degrees Celsius, the thermostat will automatically turn on the heating function. When the indoor temperature rises to 7 degrees Celsius, the thermostat will automatically turn off the heating.
Installation Steps
1. Gently pry open the device display panel using a screwdriver.
2. Install expansion screw sleeves with a spacing of 59mm on the wall. Place the backplate in the installation position, insert, and tighten the screws.
3. Re-attach the panel to complete the installation.
Inspection Steps
The intelligent touch screen thermostat should be installed in a location where users can easily view the screen and adjust the temperature setting point. Position the thermostat in a location that represents the overall ambient temperature of the room. Avoid installing the temperature controller near cold and heat sources, such as ventilation openings, heaters, outdoors, or places exposed to direct sunlight.
Common Fault Handling
Phenomenon | Processing Method |
---|---|
Not turning on | 1. Check if the battery is installed backwards. 2. Check if the power button is valid. |
Display garbled characters | Is the installation of the rear shell deformed? It can be loosened and reinstalled. |
Normal display without output | 1. Check if the wiring between the main control board and the power board is damaged. 2. Check if the output is wired incorrectly. |
Temperature display error | Calibrate panel temperature display through the first option of advanced options. |